Mouse Thromboxane B2 (TXB2) ELISA Kit

Cat. No.: EJ1515543
주문 가능
GRADE & PURITY BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. for Enzyme immunoassay(ELISA) ? ELISA grade — low-background reagents validated for enzyme immunoassays. Use to build sensitive, reproducible ELISA assays.
★
Size
USA
독일 (EU)*
Price
Qty
48T
EJ1515543-48T
주문제작 · 8~12주
US$499.90
96T
EJ1515543-96T
US 주문제작 · 2–4주 ·
—
US$739.90
Enter a quantity for the sizes you want to add.
🧪

Why this grade

BioReagent, for Enzyme immunoassay(ELISA) BioReagent,효소면역측정법(ELISA)용 for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Store at 2-8°C Ships Wet ice Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

개요

Thromboxane B2 (TXB2) is an inactive metabolite/product of thromboxane A₂. It is almost completely cleared in urine. It does not participate in platelet activation and aggregation itself, whereas its precursor thromboxane A₂ does. Thromboxane A₂ synthesis is the target of aspirin, which inhibits COX-1 enzyme (the source of thromboxane A₂ in platelets). 2-(3,4-dihydroxyphenyl)ethanol (DHPE) is a phenolic component in extra virgin olive oil. Olive oil fractions containing DHPE can inhibit platelet aggregation and thromboxane B₂ formation in vitro.


Assay Principle

This kit adopts competitive enzyme-linked immunosorbent assay (ELISA). Samples, standards, biotin-labeled antibody and HRP conjugate are sequentially added into microplates pre-coated with mouse thromboxane B2 (TXB2) antigen, followed by incubation and washing steps. Color development is performed with TMB substrate. TMB turns blue under the catalysis of horseradish peroxidase (HRP), and finally converts to yellow after acid termination. The color intensity is negatively correlated with the concentration of mouse thromboxane B2 (TXB2) in samples. The absorbance (OD value) is measured at 450 nm using a microplate reader for calculation of sample concentrations.


Precautions

1. Strictly follow the specified incubation time and temperature to guarantee accurate results. All reagents must be equilibrated to room temperature (20–25°C) before use. Refrigerate reagents immediately after use.

2. Improper plate washing may lead to inaccurate readings. Ensure complete removal of residual liquid in wells prior to substrate addition. Avoid prolonged drying of microwells throughout the procedure.

3. Wipe residual liquid and fingerprints from the bottom of the microplate, as contaminants will interfere with OD values.

4. The TMB substrate solution shall remain colorless; discard substrate solution that has turned blue.

5. Prevent cross-contamination between reagents and samples to avoid erroneous test results.

6. Avoid direct intense light exposure during reagent storage and incubation.

7. All reaction reagents must not come into contact with bleach solvents or their volatile fumes; bleach components will destroy the biological activity of kit reagents.

8. Do not use expired products; components from different lot numbers or batch codes cannot be mixed.

9. Recombinant proteins from external sources may fail to be recognized due to mismatched antibody affinity with kit capture antibodies.

10. Handle all potentially infectious samples properly, and dispose of specimens and testing devices in accordance with standardized biosafety protocols.


Kit Components:
EJ1515543ComponentsAppearance48T96TStorage
EJ1515543APre-coated Assay Plate—48wells96wells2-8℃.
EJ1515543BStandardSolid1vial2 vials2-8℃.
EJ1515543CUniversal DiluentLiquid1×20mL2×20mL2-8℃.
EJ1515543DBiotin-antibody (100×)Liquid30μL60μL2-8℃.
EJ1515543EStreptavidin-HRP (100×)Liquid60μL120μL2-8℃.
EJ1515543FWash Buffer (20×)Liquid1×10mL2×10mL2-8℃.
EJ1515543GTMB SubstrateLiquid5mL10mL2-8℃.
EJ1515543HStop SolutionLiquid3mL6mL2-8℃.
EJ1515543IPlate Sealer—4 pieces4 pieces2-8℃.
Note: EJ1515543B、EJ1515543D、EJ1515543E and EJ1515543F shall be diluted in accordance with the instructions.


Sample Handling & Requirements

1. The detectable concentration range of the kit does not equal the analyte concentration range in raw samples. It is recommended to estimate sample analyte concentrations via relevant literature and conduct pre-tests to confirm actual concentrations before formal experiments. Dilute or concentrate samples appropriately if analyte levels fall outside the linear range.

2. If your sample matrix is not listed in this manual, perform a pre-test to verify assay compatibility.

3. Serum: Collect whole blood in serum separation tubes, incubate at room temperature for 2 hours or store overnight at 2–8°C, then centrifuge at 1000×g for 20 minutes. Harvest supernatant for immediate testing, or aliquot and store at -20°C / -80°C; avoid repeated freeze-thaw cycles.

4. Plasma: Collect blood with EDTA or heparin as anticoagulant. Centrifuge specimens within 30 minutes post-collection at 1000×g, 2–8°C for 15 minutes. Collect supernatant for immediate testing, or store at -20°C / -80°C; avoid repeated freeze-thaw cycles.

5 Tissue Homogenate: Rinse tissue with pre-cooled PBS (0.01 M, pH=7.4) to remove residual blood (lysed erythrocytes in homogenate interfere with detection results). Weigh and mince tissue, then mix tissue with PBS at a standard weight-to-volume ratio of 1:9 (e.g., 1 g tissue corresponds to 9 mL PBS; adjust volume as required and record details. Addition of protease inhibitor cocktail to PBS is recommended). Transfer the mixture to a glass homogenizer and grind thoroughly on ice, or use a mechanical homogenizer. For complete cell lysis, sonicate the homogenate or perform repeated freeze-thaw cycles. Finally, centrifuge the homogenate at 5000×g for 5–10 minutes and collect supernatant for testing.

6. Cell Culture Supernatant: Centrifuge culture medium at 1000×g for 20 minutes, collect supernatant for immediate testing, or store at -20°C / -80°C; avoid repeated freeze-thaw cycles.

7. Cell Lysate: For adherent cells, wash gently with pre-cooled PBS, digest with trypsin, then harvest cells by centrifugation at 1000×g for 5 minutes. Suspension cells can be pelleted directly by centrifugation. Wash harvested cells 3 times with pre-cooled PBS, resuspend 1×10⁶ cells in 150–200 μL PBS (protease inhibitors are recommended; reduce PBS volume if analyte abundance is extremely low). Lyse cells via repeated freeze-thaw or sonication. Centrifuge the lysate at 1500×g, 2–8°C for 10 minutes and retain the supernatant for detection.

8. Other Biological Matrices: Centrifuge samples at 1000×g for 20 minutes and collect supernatant for testing.

9. Sample Appearance: Samples must be clear and transparent; all suspended particulates must be removed by centrifugation.

10. Sample Storage: Samples intended for testing within 1 week can be stored at 4°C. For delayed testing, aliquot samples into single-use volumes and freeze at -20°C (stable for 1 month) or -80°C (stable for 6 months). Avoid repeated freeze-thaw cycles. Hemolyzed samples are unsuitable for this assay, as hemolysis will distort final detection results.


Sample Dilution Protocols 

Estimate analyte concentration in advance. Follow the dilution schemes below if sample dilution is required:

100-fold dilution (single step): Mix 5 μL sample with 495 μL Assay Diluent.

1000-fold dilution (two-step): Step 1: Dilute 5 μL sample into 95 μL diluent (20×). Step 2: Transfer 5 μL of the 20× diluted sample into 245 μL diluent (50×), achieving total 1000-fold dilution.

100000-fold dilution (three-step): Step 1: Mix 5 μL sample with 195 μL diluent (40×). Step 2: Transfer 5 μL 40× sample into 245 μL diluent (50×). Step 3: Transfer 5 μL 2000× sample into 245 μL diluent (50×), total dilution factor = 100000×.

Guidelines for dilution: Transfer volume per step ≥ 3 μL; single-step dilution factor ≤ 100×. Mix thoroughly after each dilution and avoid bubble formation.


Required Lab Equipment (User-Supplied)

1. Microplate reader (capable of 450 nm absorbance measurement)

2. High-precision pipettes and matching tips: 0.5–10 μL, 5–50 μL, 20–200 μL, 200–1000 μL

3. 37°C incubator

4. Distilled or deionized water


Pre-Assay Reagent Preparation

1. Remove the kit from refrigeration 10 minutes in advance and equilibrate to room temperature.

2. Preparation of Serial Standard Working Solution: Reconstitute the lyophilized standard with 1 mL assay diluent, leave it to stand for 15 minutes for complete dissolution, then mix gently (stock concentration =5000pg/mL). Prepare serial dilutions at concentrations of: 5000pg/mL, 2500pg/mL, 1250pg/mL, 625pg/mL, 312.5pg/mL, 156.25pg/mL, 78.12pg/mL, 0pg/mL .

Serial dilution procedure: Prepare 7 EP tubes and add 500 μL assay diluent to each tube. Transfer 500 μL of the 5000pg/mL standard working solution into the first tube and mix well to obtain a 2500pg/mL standard working solution, then perform serial transfer and mixing in sequence for subsequent tubes. The last tube serves directly as the blank well; no liquid needs to be transferred from the penultimate tube. Schematic diagram shown below.

3. Preparation of Biotin-antibody Working Solution: Centrifuge the 100× concentrated Biotin-antibody at 1000×g for 1 minute 15 minutes before use. Dilute the 100× concentrated Biotin-antibody to 1× working concentration with assay diluent (Example: 10 μL concentrate + 990 μL assay diluent). Prepare fresh right before use.

4. Preparation of Streptavidin-HRP Working Solution: Centrifuge the 100× concentrated Streptavidin-HRP at 1000×g for 1 minute 15 minutes before use. Dilute the 100× concentrated Streptavidin-HRP to 1× working concentration with assay diluent (Example: 10 μL concentrate + 990 μL assay diluent). Prepare fresh right before use.

5. Preparation of 1× Wash Buffer: Add 10 mL of 20× concentrated wash buffer into 190 mL distilled water. (Crystallization may occur in concentrated wash buffer stored in the refrigerator, which is a normal phenomenon. Place the buffer at room temperature and wait for all crystals to dissolve completely before preparation.)


Assay Procedure

1. Remove required strips from the aluminum foil pouch equilibrated at room temperature for 10 min. Seal leftover strips in a zip bag and store at 4℃.

2. Sample Loading: Add 50 μL of samples or standards of different concentrations into corresponding wells. Add 50 μL Universal Diluent to blank wells, then add 50 μL Biotin-antibody working solution to each well. Cover with Plate Sealer and incubate at 37℃ for 60 min. (Recommendation: Dilute test samples at least 1-fold with Universal Diluent before loading onto the Pre-coated Assay Plate to reduce matrix effect on results. Multiply the measured concentration by the dilution factor during final calculation. It is recommended to run all test samples and standards in duplicate.)

3. Wash: Discard liquid. Add 300 μL of 1× Wash Buffer to each well, let stand for 1 min, flick out buffer and blot dry on absorbent paper. Repeat the wash procedure 3 times (automated plate washer is acceptable).

4. Add Conjugate Working Solution: Add 100 μL Streptavidin-HRP working solution to each well. Cover with Plate Sealer and incubate at 37℃ for 30 min.

5. Wash: Discard liquid and repeat the washing procedure described in Step 3 for 5 times.

6. Add Substrate: Add 90 μL TMB Substrate to each well. Cover with Plate Sealer and incubate at 37℃ in the dark for 15 min.

7. Add Stop Solution: Take out the assay plate, add 50 μL Stop Solution directly into each well. Immediately measure OD values of each well at 450 nm. 


Data Analysis

1. Calculate the average OD values of replicate wells for standards and samples, then subtract the OD value of blank wells to obtain corrected OD values. Plot a 4-parameter logistic standard curve on log-log graph paper with concentration as the X-axis and corrected OD value as the Y-axis.

2. If the OD value of a sample exceeds the upper limit of the standard curve, dilute the sample appropriately and re-test. Multiply the measured concentration by the corresponding dilution factor for final calculation.

Reference Standard Curve Raw Data (For Illustration Only)

All data and curves below are for reference only; users must generate a standard curve based on their own experimental runs.

Concentration (pg/mL)500025001250625312.5156.2578.120
OD Value0.1880.2700.3890.6420.9291.3801.7661.842

Note: This figure is for reference only; sample concentration shall be calculated based on the standard curve generated from experimental data of each individual test run.


Kit Performance Specifications

1. Precision: Intra-assay coefficient of variation (CV) < 10%, inter-assay CV < 10%.=

2. Recovery: Three distinct concentration levels of mouse TXB2 were spiked into selected healthy mouse serum and plasma samples, and the recovery rates were calculated.

Sample Type
Range (%)
Average Recovery Rate (%)
Serum (n=8)
81-10297
Plasma (n=8)
92-105101

3. Linearity by Dilution: High-concentration mouse TXB2 was spiked into four selected healthy mouse serum and plasma samples respectively. Serial dilutions were prepared within the dynamic range of the standard curve to evaluate assay linearity.

Dilution Ratio
Recovery Index
Serum
Plasma
1:2Range (%)
83-96
88-96
1:2Average Recovery Rate (%)
9293
1:4Range (%)
89-104
87-108
1:4Average Recovery Rate (%)
9398
Troubleshooting Guide

If unsatisfactory assay results occur, take photos of color development, save experimental data, retain used microplate strips and unused reagents, then contact our technical support for troubleshooting. Refer to the troubleshooting items below:

1. Poor standard curve linearity 

① Incorrect standard dilution: Reconstitute and dilute standard strictly following recommended protocol. 

② Inaccurate pipetting: Calibrate pipettes regularly and verify tip tightness/sealing performance. 

③ Evaporation of reaction solution: Seal microplate with plate sealer film. 

④ Incomplete washing: Perform sufficient wash cycles with adequate volume of wash buffer. 

⑤ Foreign residues at well bottom: Wipe microplate bottom prior to absorbance measurement.

2. Faint or absent color development 

① Insufficient incubation duration: Adhere to specified incubation time. 

② Incorrect incubation temperature: Incubate at recommended temperature. 

③ Insufficient reagent addition volume: Verify pipette accuracy and follow operating procedure strictly. 

④ Improper reagent dilution: Double-check dilution steps for all reagents. 

⑤ Inactivated Streptavidin-HRP: Mix Streptavidin-HRP with substrate and verify activity via color reaction test.

3. Low OD readings 

① Wrong microplate reader parameter: Confirm detection wavelength setting on instrument. 

② Missing stop solution addition: Add appropriate volume of stop solution. 

③ Overlong delay before plate reading: Measure absorbance immediately after termination. 

④ Excessively high analyte concentration in sample: Determine optimal dilution factor via preliminary pre-test. 

⑤ Too low analyte concentration in sample: Determine optimal dilution factor via preliminary pre-test.

4. High background signal 

① Contaminated TMB substrate: Replace with fresh substrate solution. 

② Excess substrate incubation time: Strictly control color development duration. 

③ Wrong dilution for detection antibody or Streptavidin-HRP: Dilute reagents in accordance with official recommended protocol. 

④ Incomplete plate washing: Carry out adequate wash cycles with sufficient wash buffer volume.



Specifications

동의어
Mouse TXB2(Thromboxane B2) ELISA Kit | ELISA Kit for Thromboxane B2 (TXB2) | Mouse TXB2 (Thromboxane B2) Competitive ELISA Kit
사양 및 순도
BioReagent, for Enzyme immunoassay(ELISA)
등급
BioReagent, 효소면역측정법(ELISA)용
응용 프로그램
ELISA
샘플 유형
세럼, 세포 배양 상청액, 세포 용해물, 조직 균질화물, 플라즈마
감지 범위
1.56ng/mL~100ng/mL
탐지 방법
Competitive ELISA
감지된 종 개체
Mouse
특이성
Detecting Mouse TXB2 in samples, with no significant cross-reactivity to other homologs.
Detection instrument
Microplate reader
Detection wavelength
450nm
Repeatability
The intra- and inter-assay coefficients of variation (CV) are both <10%.
Detection duration
3.5 hours, not including equilibration and sample preparation time.
보관 및 배송
보관 조건
Store at 2-8°C
배송
Wet ice
안정성 및 스토리지
Store at 2-8℃ long term (6 months).
Contents & Storage
EJ1515543组件物理外观48T96T储存
EJ1515543A预包被酶标板—48孔96孔2-8℃.
EJ1515543B标准品固体1支2支2-8℃.
EJ1515543C通用稀释液液体1×20mL2×20mL2-8℃.
EJ1515543D浓缩Biotin-抗体100×液体30μL60μL2-8℃.
EJ1515543E浓缩酶结合物100×液体60μL120μL2-8℃.
EJ1515543F20×洗涤液液体1×10mL2×10mL2-8℃.
EJ1515543G底物(TMB)液体5mL10mL2-8℃.
EJ1515543H终止液液体3mL6mL2-8℃.
EJ1515543I封板膜—4张4张2-8℃.
备注: EJ1515543B、EJ1515543D、EJ1515543E、EJ1515543F需按说明书进行稀释。

Documentation

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

인증서(CoA, COO, BSE/TSE 및 분석 차트)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

1 results found

Lot NumberCertificate Type날짜항목
ZJ26F0838232Certificate of AnalysisAug 07, 2026 EJ1515543
자주 묻는 질문과 기사
솔루션 계산기
리뷰

고객 리뷰

Need help choosing the grade?

Our grade selection guide covers purity, stabilizer status, and application suitability for all variants in our catalog.

View BioReagent grade guide → View for Enzyme immunoassay(ELISA) grade guide →

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.