QUALITÄT & REINHEITMoligand™?Moligand™ — Aladdin's line of ligands and bioactive small molecules. Use for receptor, pathway, and binding studies needing defined small-molecule tools.
This compound belongs to the class of organic compounds known as n-benzylbenzamides. These are compounds containing a benzamide moiety that is N-linked to a benzyl group.
External Descriptors
Not available
1. Djoumbou Feunang Y, Eisner R, Knox C, Chepelev L, Hastings J, Owen G, Fahy E, Steinbeck C, Subramanian S, Bolton E, Greiner R, and Wishart DS. ClassyFire: Automated Chemical Classification With A Comprehensive, Computable Taxonomy. Journal of Cheminformatics, 2016, 8:61.
Zertifikate (CoA, COO, BSE/TSE und Analyse-Diagramm)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Lösungsrechner
Molarity Calculator
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
Bewertungen
Kundenbewertungen
Application Protocols
No item-specific, vendor-validated application protocols are provided. The following is general guidance for small-molecule screening compounds.
Stock preparation (general)
Dry solid to room temperature in a desiccator before opening. Prepare a 10–50 mM stock in anhydrous DMSO. Vortex, sonicate briefly, and, if needed, warm gently (≤40 °C) to dissolve. Centrifuge and/or filter (0.2 µm PTFE) to clarify.
Serial dilution and assay setup
Prepare serial dilutions in DMSO to maintain constant solvent. Back-dilute into assay buffer to achieve desired final concentrations with uniform DMSO (commonly 0.1–1% v/v, per assay tolerance). Include vehicle controls and, where available, positive/negative control ligands.
Plate handling
Use low-binding polypropylene plates for compound stocks; seal plates to minimize evaporation. Equilibrate plates to room temperature before opening to reduce condensation.
Interference and QC checks
Assess compound autofluorescence/absorbance across assay wavelengths; test for detergent sensitivity to flag colloidal aggregators. Confirm purity/identity by LC–MS prior to large-scale screening. If stability is uncertain, re-test concentration by UV/LC at regular intervals.
Safety note
Follow institutional SOPs and the SDS. DMSO solutions increase dermal absorption risk—avoid skin contact and wear suitable PPE.
Biological Roles
Item-specific biological roles, targets, and mechanisms are not provided for AK198. As supplied, it is a research-use small molecule intended for discovery screening.
General considerations (guidance)
Screening compounds may act as enzyme inhibitors/activators, receptor ligands, ion-channel modulators, or pathway probes; however, any such activity for AK198 must be established empirically.
Evaluate for liabilities that frequently confound assays: PAINS motifs, redox cycling, metal chelation, covalent reactivity, or colloidal aggregation. Employ counterscreens (e.g., detergent sensitivity, redox reporter assays, promiscuity panels) to determine specificity.
In cell-based contexts, assess membrane permeability (e.g., PAMPA, Caco-2), efflux liability, and cytotoxicity (ATP or resazurin readouts). Protein binding and stability in cell culture media can heavily influence apparent potency.
Translational caution
No claims are made regarding biological function, safety, or suitability in humans or animals. For research use only, as stated in the product data.
Documentation
If the CoA or vendor documentation indicates a putative target or pathway association for this CID, use that only as a starting hypothesis and corroborate with orthogonal methods (biophysical binding, chemical genetics, or CRISPR validation).
Buffer Applications
AK198 is not a buffering agent. Nonetheless, buffer compatibility is critical for screening assays using small-molecule stocks.
Practical buffer guidance (general)
Use physiologically relevant buffers (e.g., HEPES, PBS, Tris) at pH 7.2–7.5 for enzyme/receptor assays unless the biology dictates otherwise. Maintain constant ionic strength and detergent levels across wells.
Manage DMSO carryover: pre-equilibrate assay buffer with the final DMSO percentage before adding compound to minimize precipitation.
Include 0.01–0.05% non-ionic detergent (Tween-20 or Triton X-100) to mitigate aggregation artifacts when appropriate for the assay.
Avoid high concentrations of reactive components (e.g., high peroxide content in H2O2-generating systems, strong nucleophiles) until compound stability is understood.
Solubility and precipitation checks
After dilution into buffer, inspect for haze/precipitation by light scattering or plate reader nephelometry. If precipitation occurs, adjust solvent ratio, pH (if compatible), or add cyclodextrin carriers as justified.
Item-specific note
No buffer system is specified for this item; select buffers based on the biological target and confirm compound compatibility experimentally.
Green Alternatives
Green chemistry considerations focus on solvent choice and handling during screening and sample preparation, since the compound identity-specific hazards are not provided.
Greener solvent strategies (general)
Prefer water-based assay buffers with minimal organic cosolvent. Keep DMSO at the lowest effective level (often ≤0.5–1% v/v) to maintain solubility without compromising biological systems.
Where feasible, use ethanol or propylene glycol as alternative stock solvents for highly polar compounds, recognizing volatility and assay compatibility.
Comparison of common stock solvents (general)
DMSO: excellent solvency; low volatility; assay-compatible at low %; not particularly green but widely accepted; enhances dermal absorption—handle carefully.
Ethanol: bio-based options available; high volatility; flammable; compatible with many assays at ≤1% v/v.
Acetonitrile: effective but higher environmental burden; volatile and flammable; often reserved for analytical workflows.
Miniaturize assay volumes (384/1536-well) to reduce solvent use.
Use adhesive thermal plate seals to limit evaporation and emissions.
Centralize solvent recycling for ACN/MeOH from analytical work.
Item-specific note
Select the least hazardous solvent system that maintains AK198 solubility and assay performance; confirm via micro-solubility and signal interference testing.
Pharmaceutical Uses
No pharmaceutical or clinical use is claimed or supported for AK198. It is supplied strictly for research use only.
General context (guidance)
Screening compounds may serve as starting points for medicinal chemistry campaigns, where structure–activity relationships (SAR), ADME properties, and developability are optimized. Any excipient roles or formulation strategies would pertain only to later-stage candidates and do not apply to this research reagent.
Analytical and development support (non-clinical)
Compounds like AK198 can be used as internal or external standards in method development (e.g., LC–MS/MS method validation exercises) provided their stability and detectability are verified.
Compliance note
Not intended for human or veterinary use, clinical diagnostics, or as an API/excipient in manufacturing. No pharmacopeial status is indicated.
Physical Properties
Item-specific physical constants are not provided in the product data and should be confirmed on the CoA.
Item-specific values
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
Melting point / boiling point: Not specified for this item; refer to CoA/Spec Sheet.
Density, refractive index: Not specified for this item; refer to CoA/Spec Sheet.
Aqueous/organic solubility: Not specified for this item; refer to CoA/Spec Sheet.
LogP/logD, pKa(s): Not specified for this item; refer to CoA/Spec Sheet.
General expectations for screening small molecules (literature/guidance)
Many library members are crystalline or amorphous solids with moderate molecular weights and melt ranges that aid solid handling. Solubility often favors polar aprotic solvents (DMSO, DMF, acetonitrile) with variable water compatibility depending on ionizable groups. Typical assay stocks are 10–50 mM in dry DMSO, then diluted into aqueous buffers to ≤1–2% DMSO v/v final.
If properties are unknown, perform a micro-solubility screen (water, PBS pH 7.4, DMSO, MeOH, ACN) at room temperature, followed by kinetic solubility in assay buffer. Determine precipitation visually and by nephelometry or UV–Vis turbidity.
Measure purity by LC–UV at multiple wavelengths (e.g., 210/254/280 nm) and confirm mass by LC–MS. Where stability is uncertain, conduct forced-degradation (light, heat, pH 2/10, oxidative) to map liabilities.
Quality and Grades
Item-specific grade
Grade/Purity: Moligand™ (screening-library grade). Specific purity, residual solvent limits, water content, and analytical thresholds: Not specified for this item; refer to CoA/Spec Sheet.
What Moligand grade means (general explanation)
Moligand-grade materials are intended for discovery workflows (HTS, biochemical/biophysical assays, phenotypic screening). Lots are typically supported by analytical identity confirmation (e.g., LC–MS) and chromatographic purity assessment suitable for screening decisions. UV background and impurity profiles are managed to minimize assay interference; however, end-users should verify fitness-for-purpose in their assay matrix.
Stabilizers and additives
Stabilizers/inhibitors: Not specified for this item; refer to CoA/Spec Sheet. If present, note potential assay interference and include appropriate controls.
Recommended incoming QC (general)
Verify identity by LC–MS and 1H NMR on receipt. Confirm purity by HPLC at multiple wavelengths. For plate-based use, test a small pilot dilution series in the actual assay buffer to check for precipitation or signal artifacts (e.g., inner-filter effects, fluorescence interference).
Documentation
For any item-specific limits (e.g., assay-ready purity, salt form, counter-ion, hydrate/solvate state), consult the CoA/Spec Sheet. Contact Aladdin Scientific for lot-resolved analytical data as needed.
Reaction and Applications
This product is positioned as a Moligand screening compound for research discovery. No item-specific synthetic reactivity is provided.
Primary applications (general for library compounds)
Biochemical target screening (enzymes, receptors) using readouts such as fluorescence polarization, FRET, TR-FRET, AlphaLISA/AlphaScreen, enzyme kinetics, or reporter assays.
Biophysical binding assays: SPR, MST, DSF/thermal shift, ITC for KD determination and mechanism-of-inhibition profiling.
Phenotypic/cell-based assays for hit identification and pathway deconvolution; recommended to include orthogonal counterscreens and cytotoxicity panels to flag promiscuity.
Computational triage/docking and ligand-based similarity searches leveraging the provided registry identifiers (PubChem CID).
Practical considerations
Prepare concentrated DMSO stocks, confirm solubility/clarity after dilution into assay buffer. Keep final DMSO constant (typically ≤1–2% v/v; confirm assay tolerance).
Control for assay interference: include detergent (e.g., 0.01–0.05% Tween-20) where appropriate to mitigate aggregation; add redox controls if the target is oxidation-sensitive.
Validate hits by re-sourcing and orthogonal analytics (LC–MS purity, HRMS identity, 1H NMR). Test for colloidal aggregation using detergent sensitivity or DLS.
Not typically applicable
As a finished screening compound, AK198 is not presented as a synthetic reagent for named organic reactions; see “Synthetic Utility” for limited analytical uses.
Reaction Conditions
This section is not typically applicable because AK198 is supplied as a screening compound, not as a reagent for carrying out named synthetic reactions.
General guidance (if chemical modification is contemplated)
Establish structure and functional groups via CoA and independent analytics. Pilot any derivatization on sub-milligram scale first, monitoring by LC–MS.
Choose solvents and temperatures compatible with the confirmed functional groups (e.g., avoid strong base for base-labile motifs, minimize heating for thermally sensitive heterocycles).
Typical small-molecule transformations use polar aprotic solvents (DMF, DMSO, ACN), mild bases (DIPEA, Cs2CO3), and catalysts as needed; however, none are recommended here without structural knowledge.
Item-specific values (temperature, time, yields)
Not specified for this item; refer to CoA/Spec Sheet if any modification guidance is provided.
Safety and Handling
Safety details specific to this item are not provided in the product data; consult the SDS for authoritative guidance.
Item-specific hazard info
Signal word: Not specified for this item; refer to SDS.
GHS classification and pictograms: Not specified for this item; refer to SDS.
H-statements: Not specified for this item; refer to SDS.
General laboratory precautions (guidance)
Handle as a potentially hazardous organic small molecule. Avoid inhalation, ingestion, and skin/eye contact. Use in a fume hood with appropriate PPE: lab coat, safety glasses, and disposable nitrile gloves (double-glove when using DMSO or other skin-permeating solvents).
Avoid incompatible materials until known (strong oxidizers, strong acids/bases may cause degradation). Keep away from ignition sources and static discharge if the material or its solvents are flammable.
DMSO and DMF can enhance dermal absorption; prevent skin contact with solutions. Clean spills with absorbent pads, then wash area with appropriate solvent and detergent per institutional procedures.
First-aid overview (guidance; defer to SDS)
Skin/eye contact: Rinse with water for at least 15 minutes; remove contaminated clothing. Seek medical attention if irritation persists.
Inhalation: Move to fresh air; seek medical attention if symptoms occur.
Ingestion: Rinse mouth; do not induce vomiting; seek medical attention.
Waste
Collect solid and solution waste as halogenated or non-halogenated organic waste per local regulations and solvent composition.
Solvent Selection
Item-specific solubility data are not provided. The following guidance supports rapid solvent selection for small-molecule screening compounds.
Primary stock solvent (general best practice)
Dimethyl sulfoxide (DMSO) is the default due to broad solvency and assay compatibility at ≤1–2% v/v. Prepare 10–50 mM stocks as solubility permits.
Secondary solvents and co-solvent strategies
If DMSO solubility is limited, consider DMF, N-methyl-2-pyrrolidone (NMP), or acetonitrile for intermediate concentrates, then back-dilute into DMSO. For aqueous delivery, pre-wet target buffer with DMSO (e.g., 2–5%) before adding the concentrate to minimize precipitation.
For more polar/ionizable molecules, 50–100% methanol or ethanol stocks can work, mindful of assay tolerances and volatility.
Polarity and miscibility (general)
DMSO, DMF, NMP: polar aprotic, fully miscible with water and most organics; strong hydrogen-bond acceptors.
ACN, MeOH, EtOH: water-miscible; lower viscosity, faster evaporation (beneficial for drying, but can cause edge effects in plates).
Practical tips
Warm gently (25–40 °C) and sonicate to aid dissolution. Avoid prolonged heating that may degrade sensitive chemotypes.
Filter (0.2 µm PTFE) or centrifuge stocks to remove particulates before plating.
Maintain constant final solvent composition across wells to avoid solvent bias.
Item-specific note
Definitive solvent choices for AK198 should be based on the lot CoA solubility notes or small-scale solubility screening.
Storage and Reconstitution
Item-specific storage
Storage Conditions: Room temperature (from Product Data) for unopened, dry material. Shipped-in conditions: Not specified for this item; refer to CoA/Spec Sheet.
General storage guidance (dry solid)
Store in original, tightly closed container in a desiccator, protected from light and humidity. If the compound is hygroscopic, light-sensitive, or air-sensitive (not specified), minimize exposure during handling. Record first-open date for inventory control.
Solution handling (general guidance)
Prepare assay stocks in anhydrous DMSO. For working solutions, aliquot into inert, light-protective vials/plates to minimize freeze–thaw and headspace moisture. While dry solid may be kept at room temperature, DMSO solutions are best stored at −20 to −80 °C for longevity; thaw at room temperature and vortex before use. Avoid repeated freeze–thaw by aliquoting.
Stability
Appearance, purity, and assay performance should be verified periodically. Any item-specific stability limits, salt form, or hydrate state: Not specified for this item; refer to CoA/Spec Sheet.
Research use
For research use only, as indicated by the product data.
Structure and Identity
Concise overview of identity and available registry data for this Moligand screening compound.
Item-specific (from Product Data)
SKU: A607471
Product Name: AK198 (Moligand screening compound)
CAS: A607471 (catalog reference; not a classical CAS RN)
PubChem CID: 91820714
InChIKey: 100653
Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
SMILES: Not specified for this item; refer to CoA/Spec Sheet.
Structural features
Item-specific 2D/3D structure, stereochemistry, and functional groups are not provided in the product data and should be confirmed from the CoA/Spec Sheet or by independent analysis (e.g., NMR, HRMS, LC–MS).
General chemistry note (literature/guidance)
Moligand compounds are typically drug-like small molecules curated for screening collections. They may contain heteroaromatic rings, hydrogen bond donors/acceptors, and diverse lipophilicity to cover chemical space, but exact features must be verified per lot.
Recommended identity confirmation (general)
Orthogonal identity tests such as 1H/13C NMR, HRMS (ESI), LC–MS purity profile, and, where applicable, IR and HPLC retention index. If chirality is indicated in the CoA, determine enantiomeric/diastereomeric ratio by chiral HPLC.
Synthetic Utility
AK198 is provided as a finished small-molecule screening entity rather than a synthetic reagent or building block.
Item-specific reactivity
Functional groups and synthetic handles are not specified; do not assume suitability for downstream transformations without structural confirmation from the CoA.
General uses in synthesis workflows (guidance)
Reference standard: may be employed to develop and qualify analytical methods (LC–UV/LC–MS retention, ionization behavior) or to benchmark purification and fraction collection settings.
Stability mapping: use stress testing (acid/base, oxidative, photolytic) to identify potential liabilities that inform medicinal chemistry optimization.
If the structure contains tractable handles (to be confirmed), derivatization may be possible to generate probe analogs or biotin/fluorophore conjugates for target engagement studies; proceed only after verifying identity and purity.
Limitation
Absent explicit structural data, AK198 should not be assumed to participate in named synthetic transformations or to possess defined nucleophilic/electrophilic reactivity profiles.
Target Specificity
No target specificity, selectivity profile, or intended biological target is provided for AK198 in the product data.
Item-specific data
None available; refer to CoA/Spec Sheet or associated screening panel data if supplied for a given lot.
General guidance
Determine specificity via orthogonal assays (biochemical and biophysical) and use selectivity panels against close homologs/isoforms. Consider broad profiling (e.g., kinome, GPCR, ion-channel panels) if relevant to your target class.
Evaluate potential assay interference and aggregation to avoid false attribution of specificity.
Häufig gestellte Fragen
What is Moligand??
Moligand? is one of Aladdin Scientific's premium product lines, formulated for high-purity applications across multiple workflows. Compared to standard grades in the same workflow, Moligand? products typically offer tighter specifications, more rigorous QC, and stronger lot-to-lot consistency.
How should this product be stored?
Store at room temperature.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is A607471. InChIKey GFJYPJDGRCZNDI-UHFFFAOYSA-N.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.
Benötigen Sie Hilfe bei der Auswahl der Qualität?
Unser Leitfaden zur Qualitätsauswahl behandelt Reinheit, Stabilisatorstatus und Anwendungseignung für alle Varianten in unserem Katalog.
Wir verwenden Cookies, um die ordnungsgemäße Funktion der Website sicherzustellen und, soweit zulässig, Ihr Nutzererlebnis zu verbessern. Sie können Ihre Einstellungen jederzeit unter „Einstellungen“ verwalten. Weitere Informationen finden Sie in unserer Cookie-Richtlinie.
Dürfen wir Sie über Rabattaktionen informieren?
Später erinnern
Vielen Dank! Bitte überprüfen Sie Ihren E-Mail-Posteingang, um zu bestätigen.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.