Citrate-EDTA Antigen Retrieval Solution (40X) - BioReagent, sterile-filtered, sterile, Suitable for Immunohistochemistry, 40X

Cat. No.: C752118
Zu bestellen verfügbar
GRADE & PURITY Sterile-filtered ? Sterile-filtered — passed through a 0.2µm filter to remove microorganisms. Use as a ready aseptic solution for culture and sensitive applications. BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. Sterile ? Sterile grade — processed and verified free of viable microorganisms. Use directly in aseptic procedures and cell culture without further sterilization. Suitable for Immunohistochemistry(IHC) ? IHC grade — validated for immunohistochemistry on tissue sections. Use to detect and localize antigens in fixed tissue. 40X
Synonyms
Citrate-EDTA Antigen Retrieval Solution (40X)
Storage
Store at 2-8°C
Shipped In
Wet ice
★
Size
Deutschland (EU)
USA*
Price
Qty
100ml
C752118-100ml
—
2 Auf Lager
25,95€
Enter a quantity for the sizes you want to add.
🧪

Why this grade

BioReagent, sterile-filtered, sterile, Suitable for Immunohistochemistry, 40X BioReagent,Steril gefiltert,Sterile,Suitable for Immunohistochemistry(IHC) for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Store at 2-8°C Ships Wet ice Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

Übersicht

Sodium citrate -EDTA antigen repair solution (40×) can repair the protein cross-linking caused by fixed solution such as paraformaldehyde, prevent the signal weakening of immunostaining caused by the masking of antigen sites or false positive staining results caused by antigen recognition errors, and fully expose the antigen epitope in paraffin sections and other samples, thus greatly improving the effect of immunostaining. Suitable for paraffin section, frozen section and other samples.
Procedure: 
1. Before the reagent is ready for use, sodium citrate -EDTA antigen repair solution (40×) must be diluted with distilled water or ultra-pure water to form antigen repair solution (1×). 
2. Antigen Repair 
2.1 For paraffin sections: 
2.1.1 Dewaxing: Sections are dewaxed in xylene for 2×5min. Anhydrous ethanol 2×5min. 90% ethanol 2×5min, 70% ethanol 5min. Distilled water 2×5min.
2.1.2 Antigen repair: The section is immersed in antigen repair solution (1×) and heated at 95-100°C for about 10~30min(the best heating time should be determined according to different samples and target proteins). 
Note: Antigen repair solution (1×) should be preheated to 95-100°C before use. Heat can be done in a water bath or microwave. If using microwave oven heating, pay attention to avoid the repair solution boiling. Then cool to room temperature in about 20 to 30 minutes. Wash with immunostaining detergent 1~2 times, 3~5min each time. Subsequent immunostaining steps such as blocking can be performed. 
2.2 Frozen section: The section was washed with immunostaining detergent for 5min. The process of antigen repair such as the process of antigen repair in paraffin sections. 
2.3 The antigen repair of other samples can be carried out by referring to the steps of paraffin section.
Tips: For your own safety, please take good protection before using the reagent, such as wearing a lab coat, wearing gloves, etc.


Specifications

Synonyme
Citrate-EDTA Antigen Retrieval Solution (40X)
Spezifikationen & Reinheit
BioReagent, sterile-filtered, sterile, Suitable for Immunohistochemistry, 40X
Stabilität und Lagerung
Store at 2-8℃ for 12 months. Store at -20℃ for 24 months. Upon receipt, it is recommended to aliquot. Avoid freeze/thaw cycle.
Storage
Store at 2-8°C
Verschickt in
Wet ice
Dieses Produkt erfordert Kühlkettenversand. Grundversand und andere Economy-Optionen sind nicht verfügbar.
Note
BioReagent, Steril gefiltert, Sterile, Suitable for Immunohistochemistry(IHC)

Documentation

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Zertifikate (CoA, COO, BSE/TSE und Analyse-Diagramm)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

1 results found

Lot NumberCertificate TypeDatumArtikel
ZJ25F0319950Certificate of AnalysisOct 08, 2026 C752118
FAQs und Artikel
Lösungsrechner
Bewertungen

Kundenbewertungen

Häufig gestellte Fragen

What does sterile-filtered mean?
sterile-filtered indicates that the material has been processed and tested for specialty industrial processing. Specifications focus on the impurities that affect performance in that application — for example, metal content for electronics, particle size for batteries, refractive index for optics, or moisture content for moisture-sensitive processes.
What does BioReagent mean?
BioReagent indicates that the product has been processed and tested for biological and biochemical applications. Specifications may include endotoxin limits, microbial controls, sterility, low DNase/RNase/protease activity, and verified biological activity where relevant.
How should this product be stored?
Store at 2–8 °C. Refrigerated storage is required to maintain the specified shelf life.
How is this product shipped?
This product ships chilled on wet ice. Unpack on arrival and transfer it to the storage condition stated above.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.