Decalcification Endpoint Detection Kit (Chemical Method)

Cat. No.: D1527424
Zu bestellen verfügbar
QUALITÄT & REINHEIT BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.
★
Größe
Deutschland (EU)
USA*
Preis
Menge
100T
D1527424-100T
Auf Bestellung · 8–12 Wochen
65,86€
Enter a quantity for the sizes you want to add.

Übersicht

When some tissues contain bone or calcified foci, calcium‑containing tissues should not be directly embedded in paraffin for sectioning. This is due to the density difference between calcium and paraffin, which makes it difficult to obtain intact sections. For calcium‑containing tissues, decalcification is preferably performed after fixation, or fixation and decalcification can be carried out simultaneously. Subsequent procedures such as dehydration, clearing, wax infiltration, embedding and sectioning are then performed. A variety of reagents are available for decalcification, including organic acids, inorganic acids, ethylenediaminetetraacetic acid (EDTA), and electrolytic decalcification. During decalcification, the degree of decalcification should be monitored at regular intervals to avoid over‑decalcification. Over‑decalcification will aggravate tissue damage and further affect staining results.

This product consists of ammonia solution, ammonium oxalate and other components. The absence of precipitate after adding ammonium oxalate indicates that the decalcification endpoint has been reached. This reagent is for research use only and is not intended for clinical diagnosis or other applications.

Component

Component No.Component NameAppearance50TStorage
D1527424AAmmonia SolutionLiquid100ml RT
D1527424BAmmonium Oxalate SolutionLiquid10ml RT

Procedure (For Reference Only)

1. Take 5 mL of the in‑use decalcifying solution, add 1 mL of ammonia solution, and mix thoroughly.

2. Add 0.1 mL of ammonium oxalate solution and mix thoroughly.

3. Observe for precipitate formation. If decalcification is incomplete, precipitate formation indicates effective decalcification. No precipitate after addition of ammonium oxalate indicates that the decalcification endpoint has been reached.

Notes

1. This method is not suitable for decalcification by ion‑exchange resin method or EDTA method.

2. Monitor the degree of decalcification at regular intervals to avoid over‑decalcification. Over‑decalcification will exacerbate tissue damage and affect staining results.

3. For your safety and health, wear a lab coat and disposable gloves during operation.

Shelf‑life

Valid for 12 months.

Spezifikationen

Spezifikationen & Reinheit
BioReagent
Note
BioReagent
Lagerung und Versand
Storage
Room temperature
Verschickt in
Normal
Stabilität und Lagerung
Store at room temperature long term (12 months).
Contents & Storage
Component No.Component NameAppearance100100mlTStorage
D1527424AAmmonia SolutionLiquid100ml RT
D1527424BAmmonium Oxalate SolutionLiquid10ml RT

Erweiterte Daten

Zertifikate (CoA, COO, BSE/TSE und Analyse-Diagramm)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
FAQs und Artikel
Lösungsrechner
Bewertungen

Kundenbewertungen

Dürfen wir Sie über Rabattaktionen informieren?

Später erinnern

Vielen Dank! Bitte überprüfen Sie Ihren E-Mail-Posteingang, um zu bestätigen.

Hoppla! Benachrichtigungen sind deaktiviert.