Exosome Assay Kit (ELISA Sandwich Method) - BioReagent, sterile, high purity

Cat. No.: E778166
AVAILABLE TO ORDER
GRADE & PURITY BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. Sterile ? Sterile grade — processed and verified free of viable microorganisms. Use directly in aseptic procedures and cell culture without further sterilization.
 ·  off list, applied to all prices below.
Size
Status
Price
Qty
24T
E778166-24T
1-2 wks(?)
Item is derived from our semi-finished stock and is processed in 1-2 weeks.
$619.90
48T
E778166-48T
1-2 wks(?)
Item is derived from our semi-finished stock and is processed in 1-2 weeks.
$909.90
96T
E778166-96T
1-2 wks(?)
Item is derived from our semi-finished stock and is processed in 1-2 weeks.
$1,359.90
Enter a quantity for the sizes you want to add.
🧪

Why this grade

BioReagent, sterile BioReagent,Sterile for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Store at 2-8°C,Protected from light,Store at -20°C Ships Wet ice Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

Overview

This product is an exosome qualitative and quantitative detection kit based on the sandwich ELISA method. It adopts high-performance CD9 capture antibody and CD81 detection antibody to sensitively detect CD9 and CD81 targets co-expressed on the surface of exosomes. Compatible with various samples such as human body fluids and cell culture media, this kit enables rapid and accurate quantification of exosomes in raw samples.


E778166
Component
24T
48T
96T
Storage
E778166A
Capture Antibody-Coated Microplate
24 wells
48 wells
96 wells
2-8°C
E778166B
Exosome Standard S1
1 mL
1 mL
1 mL
-20°C
E778166C
Enzyme Conjugate
2.5 mL
5 mL
10 mL
2-8°C
E778166D
Chromogenic Solution A
1.5 mL
3 mL
6 mL
2-8°C. Store in the dark.
E778166E
Chromogenic Solution B
1.5 mL
3 mL
6 mL
2-8°C. Store in the dark.
E778166F
Stop Solution
1.5 mL
3 mL
6 mL
2-8°C
E778166G
Concentrated Wash Buffer (20×)
7.5 mL
15 mL
30 mL
2-8°C
E778166H
Assay Diluent
1.25 mL
2.5 mL
5 mL
2-8°C
E778166I
Exosome Standard S2
1 mL
1 mL
1 mL
-20°C
E778166J
Exosome Standard S3
1 mL
1 mL
1 mL
-20°C
E778166K
Exosome Standard S4
1 mL
1 mL
1 mL
-20°C
E778166L
Exosome Standard S5
1 mL
1 mL
1 mL
-20°C

Product Features:

Wide Application: Compatible with various sample types including cell culture supernatant, urine, serum, etc.

Easy Operation: Only a microplate reader with 450 nm wavelength is required; no additional equipment is needed.

Excellent Stability and Reproducibility: This kit adopts CD9/CD81 fusion protein standards instead of native exosomes, which are unstable and hard to preserve, to guarantee superior stability and repeatability.

Exosome Integrity Assay: Enables rapid evaluation of exosome integrity.


Product Principle:

Test Procedure:

1. Pre-test Preparation

① All reagents shall be equilibrated to room temperature for at least 15 minutes before use.

② Dilute the 20× Concentrated Wash Buffer with distilled or deionized water to prepare 1× working solution, mix thoroughly for later use. (The kit is supplied with assay diluent, which can be used to dilute high-concentration standards as required.)

2. Operating Steps

① Take the equilibrated microplate strips and reagents, and fully shake all reagents evenly.

② Add serially diluted Exosome Standards and test samples into respective wells of the microplate (100 μL per well).

③ Seal the reaction wells with plate sealer, and incubate at a constant temperature of 37 °C away from light for 60 min.

④ After incubation, wash wells with wash working solution 3 times, 200–250 μL per well each time. Blot dry on absorbent filter paper after washing.

⑤ Add 100 μL Enzyme Conjugate to each well, seal the plate, and incubate at 37 °C in the dark for 60 min.

⑥ Repeat the washing procedure 3 times as described above, then blot dry completely.

⑦ Prepare chromogenic substrate working solution: mix Chromogenic Solution A and Solution B at an equal volume ratio. Use the mixed substrate within 2 minutes after preparation.

⑧ Pipette 100 μL freshly prepared chromogenic substrate working solution into each well, and incubate at 37 °C protected from light for 30 min.

⑨ Add 50 μL Stop Solution to each well, mix gently, and measure OD₄₅₀ values immediately (within 3 min). Plot an XY linear calibration curve.

3. Calibration Protocol

XY linear fitting is adopted, with a mandatory requirement that the coefficient of determination R² ≥ 0.99. A full set of calibrants must be tested in each independent experiment to generate the calibration curve.

校准点
S1
S2
S3
S4
S5
Concentration (ng/mL)
0
7.816
15.625
31.2545
OD₄₅₀
0.07370.30740.51830.86181.2945

                                                                Exosome Standard Calibration Curve

                                                                                Concentration (ng/mL)

Note: This figure is for reference only. The concentration of exosomes in samples shall be calculated based on the standard curve generated from standards tested in the same assay run.

Precautions and Disclaimer

1. This kit shall be stored away from light.

2. This product is intended solely for scientific research use by professionals. It must not be used for clinical diagnosis, clinical treatment, food or pharmaceutical applications.     

Storage and Shipping
Storage
Store at 2-8°C,Protected from light,Store at -20°C
Shipped In
Wet ice
Stability And Storage
E778166B:Store at -20℃ long term (12 months). Upon receipt, it is recommended to aliquot. Avoid freeze/thaw cycle. E778166D、E778166E:Store at 2-8℃ long term (12 months). Store in the dark. E778166A、E778166C、E778166F、E778166G、E778166H:Store at 2-8℃ long te

Documentation

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Certificates(CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

3 results found

Lot NumberCertificate TypeDateItem
ZJ25F0927272Certificate of AnalysisJul 07, 2026 E778166
ZJ25F0927271Certificate of AnalysisJul 07, 2026 E778166
F2626288Certificate of AnalysisJun 27, 2026 E778166
Documents & Articles
Solution Calculators
Reviews

Customer Reviews

Need help choosing the grade?

Our grade selection guide covers purity, stabilizer status, and application suitability for all variants in our catalog.

View BioReagent grade guide → View Sterile grade guide →

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.