GS-704277 is an alanine metabolite of Remdesivir. Remdesivir, a nucleoside analogue with effective antiviral activity, is highly effective in the control of SARS-CoV-2 (COVID-19) infection in vitro.
Form:Solid
Spezifikationen
Biochemische und physiologische Mechanismen
GS-704277 is an alanine metabolite of Remdesivir. Remdesivir, a nucleoside analogue with effective antiviral activity, is highly effective in the control of SARS-CoV-2 (COVID-19) infection in vitro.
Storage
Store at 2-8°C
Verschickt in
Wet ice
Dieses Produkt erfordert Kühlkettenversand. Grundversand und andere Economy-Optionen sind nicht verfügbar.
Zertifikate (CoA, COO, BSE/TSE und Analyse-Diagramm)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Chemische und physikalische Eigenschaften
Löslichkeit
H2O : 2.17 mg/mL (4.91 mM; ultrasonic and warming and heat to 60°C) DMSO : 2 mg/mL (4.52 mM; Need ultrasonic)
Lösungsrechner
Molarity Calculator
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
Bewertungen
Kundenbewertungen
Application Protocols
The Product Data do not list validated applications for GS-704277. The following is general, fit-for-purpose guidance for small-molecule screening and profiling; adapt to your assay and validate locally.
Preparing stock solutions (general)
Warm to room temperature inside a desiccator. Weigh quickly in a fume hood. Dissolve to 10–50 mM in anhydrous DMSO. Vortex and sonicate if needed. Record lot-specific purity to correct molarity if desired.
Optional: 0.2 µm PTFE filtration to remove particulates if compatible.
Serial dilution and dosing
Prepare half-log serial dilutions in DMSO (or assay-compatible vehicle). Back-dilute into assay buffer/media to achieve final DMSO ≤0.1–1% v/v. Mix gently to avoid precipitation.
Include vehicle controls and positive/negative controls. Run at least n=3 technical replicates.
Plate-based assays
Use low-binding plates and tips to reduce adsorption. Seal plates to limit evaporation. Equilibrate temperature before readout to reduce drift.
Data quality controls
Confirm delivered concentrations by LC–MS or UV when possible. Monitor turbidity/nephelometry. Track freeze–thaw cycles and cumulative ambient exposure.
Safety
Follow SDS-based precautions; unknown toxicity warrants conservative handling.
Not specified for this item; refer to CoA/Spec Sheet.
Biological Roles
Item-specific
No biological function, endogenous role, or target annotation is provided for GS-704277 in the Product Data.
General context for small-molecule library members (not specific to this item)
Such compounds are used as exogenous test articles to perturb biological systems in vitro and sometimes ex vivo, enabling target validation, pathway interrogation, or phenotypic screening.
Any observed activity is context-dependent (assay system, concentration, exposure time) and must be corroborated with orthogonal methods to exclude artifacts (e.g., aggregation, redox cycling, assay interference).
Physicochemical properties (pKa, logD, polar surface area) govern permeability, solubility, and non-specific binding; these are Not specified for this item and should be determined experimentally if relevant.
Cautions
Avoid extrapolating screening activity to biological “roles” without mechanistic and selectivity data.
Use counterscreens and controls (detergent sensitivity, redox reporters, fluorescence interference tests) to de-risk false positives.
Research use only
This product is intended strictly for research. No clinical or diagnostic claims are made or implied.
Buffer Applications
GS-704277 is a small-molecule library compound and not a buffering agent.
Applicability
It is not typically used to make buffer systems. Buffer preparation details (pH range, capacity) therefore do not apply to this product.
Practical note (general)
When dosing small molecules into buffers (e.g., PBS, HEPES, Tris), confirm compatibility: avoid pH values that may cause ionization-state changes leading to precipitation, and keep the final DMSO fraction low (≤0.1–1% v/v as assay-appropriate).
If adsorption to plastics is suspected at low doses, precondition plates with buffer containing 0.01–0.05% non-ionic surfactant when compatible with the assay.
Item-specific buffer data
None provided; refer to CoA/Spec Sheet for any solubility or stability notes in common buffers.
Green Alternatives
Without a disclosed structure for GS-704277, the greener-choice discussion focuses on solvent and workflow selection for dissolution, handling, and analytics (general guidance):
Prefer greener solvents where assay-appropriate (general)
Replace acetonitrile or dichloromethane in sample prep with ethanol, isopropanol, or ethyl acetate when compatible.
For chromatographic development, consider water-rich reversed-phase methods (≥50% aqueous) with ethanol or 2-propanol as organic modifiers instead of ACN, acknowledging potential changes in selectivity and backpressure.
Stock solutions and dosing
Keep DMSO stock concentrations high (e.g., 10–50 mM) to minimize delivered DMSO percentage in assays, reducing solvent burden.
Use miniaturized assay volumes and sealed plates to lower solvent use and emissions.
Waste minimization
Consolidate wash solvents and segregate halogenated from non-halogenated waste.
Adopt scalable microflow LC or shorter gradients to reduce solvent consumption in analytics.
Tradeoffs (general)
Ethanol/isopropanol are greener but may alter enzyme or cell behavior compared with DMSO; perform compatibility checks.
Ethyl acetate offers better environmental metrics than chlorinated solvents but is less miscible with water; phase behavior may complicate bioassays.
Item-specific note
No compound-specific green handling constraints are provided for GS-704277. Verify stability before substituting solvents; hydrolysis/oxidation sensitivities, if any, are Not specified for this item.
Pharmaceutical Uses
No pharmacopeial status, excipient role, or manufacturing specification is provided for GS-704277.
Item-specific
Pharmaceutical/clinical use: Not specified; this product is designated For research use only.
General research/manufacturing context (non-clinical)
Compounds in discovery libraries can serve as reference standards or test articles in preclinical research, assay development, and method validation.
If used as an analytical standard, establish traceability via internal or external reference materials and document identity/purity with orthogonal methods (LC–MS, NMR).
Compliance note
This product is not manufactured to GMP and is not intended for use in humans or for diagnostic procedures. Any transition toward regulated use would require new sourcing, full specification dossiers, and stability studies.
Formulation (general, in vitro)
For in vitro applications, dissolve in DMSO to prepare concentrated stocks and dilute into assay media immediately prior to use. Confirm absence of precipitation and monitor for time-dependent degradation by LC–MS if experiments are long-running.
For this item
Specific excipient compatibility, impurity limits, and release tests are Not specified for this item; refer to CoA/Spec Sheet if available.
Physical Properties
Item-specific values are not provided in the Product Data for GS-704277.
Item-specific
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
Melting point: Not specified for this item; refer to CoA/Spec Sheet.
Boiling point: Not specified for this item; refer to CoA/Spec Sheet.
Density: Not specified for this item; refer to CoA/Spec Sheet.
Solubility: Not specified for this item; refer to CoA/Spec Sheet.
LogP/logD: Not specified for this item; refer to CoA/Spec Sheet.
pKa: Not specified for this item; refer to CoA/Spec Sheet.
Refractive index/UV cutoff: Not specified for this item; refer to CoA/Spec Sheet.
General guidance for small-molecule library members (literature/general)
Solubility screening is typically performed in DMSO first (e.g., 10–50 mM stock), followed by dilution into aqueous assay buffers keeping final DMSO ≤0.1–1% v/v to minimize assay interference.
If aqueous precipitation occurs on dilution, consider co-solvents (≤10% v/v ACN or MeOH) or surfactants (0.01–0.05% Tween-20 or Pluronic F-127) as assay-appropriate.
For analytical characterization, LC–MS (ESI±) and 1H/13C NMR are standard. Determine extinction coefficients empirically if UV/Vis quantification is planned.
Important
Do not treat the above ranges as specifications for this particular item. For exact values applicable to GS-704277, consult the current CoA/Spec Sheet.
Quality and Grades
Item-specific
Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.
Interpreting typical grades for small-molecule libraries (general)
“Screening grade” or “library grade” compounds are commonly provided at high chemical purity (often ≥90–98% by HPLC, literature/general), with identity verified by LC–MS and/or NMR. Exact thresholds vary by supplier and lot.
When UV-based assays are planned, low UV-absorbing impurities are preferred; however, UV cutoff or residue limits must be confirmed case-by-case. For this item, such details are not specified.
What to check on the CoA/Spec Sheet (practical guidance)
Purity methodology and result (e.g., HPLC area% with method parameters).
Residual solvents and water content (KF) if relevant to your assay; for this item: Not specified.
Salt form/solvate state and counter-ions (affect solubility and MW).
Stabilizers/additives
None are indicated in the Product Data; if stabilizers are present, they will be listed on the CoA/SDS. Presence of stabilizers may influence analytical baselines and bioassay readouts.
Recommendation
For quantitative SAR or in vivo–adjacent workflows, consider orthogonal purity checks (2D NMR, HRMS, chiral HPLC if stereochemistry is expected) and prepare aliquots to minimize freeze–thaw and moisture exposure.
Reaction and Applications
Item-specific
Manufacturer Applications: Not specified in the Product Data beyond inclusion in a small-molecule/compound library. For research use only.
Typical applications for library compounds (general)
Target deconvolution workflows: chemoproteomics, CETSA, or CRISPR-based modifier screens, contingent on compound properties.
Analytical reference: LC–MS retention-index mapping or method development standard.
Practical tips
Prepare a concentrated DMSO stock (e.g., 10 mM) after confirming solubility; filter (0.2 µm PTFE) if compatible to remove particulates.
For dose–response curves, use half-log serial dilutions (10–12 points) spanning at least three logs. Include vehicle and positive/negative controls.
Track freeze–thaw cycles and cumulative time at room temperature; adsorption to plastics can bias low-dose delivery—use low-bind tubes/plates.
Notes
No reaction chemistry role is implied for GS-704277 based on the Product Data; it is not presented as a reagent but as a test article for screening. Any specific target class or mechanism should be established from primary literature or internal validation; none are provided here.
Reaction Conditions
No reaction chemistry role or conditions are provided for GS-704277 in the Product Data.
Applicability
This product is not supplied as a reagent or catalyst; therefore, standard reaction conditions are not applicable.
General note (if used in stability or transformation studies; not item-specific)
To evaluate chemical stability, stress-test aliquots under controlled conditions (acid/base, oxidative, heat, light) and monitor by LC–MS. This is distinct from using the compound as a reagent in synthetic transformations.
Item-specific data
None. For any proposed chemical use beyond screening or analytical reference, obtain the full structural information and consult primary literature.
Safety and Handling
Safety data specific to GS-704277 are not provided in the Product Data. Always consult the SDS for authoritative hazard and precautionary information.
Item-specific
Storage conditions: Store at 2–8°C.
Shipping: Wet ice.
GHS classification, signal word, pictograms, H-statements: Not specified for this item; refer to SDS.
General laboratory precautions (general best practice)
Use appropriate PPE: lab coat, safety glasses, and chemically resistant gloves (e.g., nitrile). Handle powders/solids in a fume hood to minimize inhalation exposure.
Avoid contact with skin, eyes, and clothing. Prevent aerosol or dust generation during aliquoting.
Use dedicated, clean tools for weighing to avoid cross-contamination if the compound is used in screening.
Incompatibilities/housekeeping (general)
Keep away from strong oxidizers/reducers and strong acids/bases until specific compatibility is known.
Protect from moisture and prolonged exposure to air if the compound is hygroscopic or hydrolytically sensitive (unknown for this item; adopt conservative handling).
First aid (overview; defer to SDS)
Inhalation: Move to fresh air; seek medical attention if symptoms persist.
Skin/eyes: Rinse with water for at least 15 minutes; remove contaminated clothing; seek medical advice.
Ingestion: Rinse mouth; do not induce vomiting; obtain medical attention.
Note: For research use only. Not for human or animal therapeutic use.
Solvent Selection
Because the exact structure of GS-704277 is not disclosed here, select solvents using a tiered approach validated for diverse small molecules (general guidance):
Primary stock solvent
DMSO (anhydrous) is the default for discovery compounds due to broad solvency and assay compatibility at ≤0.1–1% v/v final concentration.
Secondary/cosolvents (if needed; general)
Acetonitrile (ACN) or methanol (MeOH) for LC–MS compatibility and to aid dissolution; keep low in biological assays.
Ethanol or isopropanol for cells/enzymes with known tolerance windows.
PEG400 or captisol can enhance solubility in specialized contexts (in vitro only; evaluate assay interference).
Aqueous vehicles
Dilute DMSO stocks into buffer (e.g., PBS, HEPES) immediately before use. Add compound last to minimize local supersaturation; gentle mixing helps prevent precipitation.
Solubility diagnostics
Visual inspection and nephelometry detect turbidity; LC–MS or UV at two wavelengths can confirm delivered concentration.
Small comparison (general)
DMSO: highest solvency; may affect membrane assays if >0.5–1%.
MeOH/EtOH: good solvency; enzyme/cell tolerance assay-dependent.
Note
Item-specific solubility, logP/pKa, or preferred solvents are Not specified for this item; refer to CoA/Spec Sheet. Validate solvent choice empirically for your assay.
Storage and Reconstitution
Item-specific
Storage conditions: Store at 2–8°C.
Shipping: Wet ice.
Appearance, stabilizers, and exact form (free base/salt/solvate): Not specified for this item; refer to CoA/Spec Sheet.
Reconstitution (general guidance for small molecules)
Equilibrate the container to room temperature in a desiccator before opening to minimize moisture condensation.
Prepare a concentrated DMSO stock (e.g., 10–50 mM) based on assay needs. Vortex to dissolve; brief bath sonication can assist. Verify clarity and absence of particulates.
Aliquot into amber or low-bind vials to minimize adsorption and avoid repeated freeze–thaw. Clearly label concentration, solvent, date, and lot.
Short-term handling
Keep working solutions on ice or at room temperature per assay requirements; limit time in aqueous media to reduce potential hydrolysis (compound-specific stability Not specified for this item).
Longer-term storage (general)
Store DMSO stocks tightly capped, under inert atmosphere if feasible. Common practice is −20 to −80°C for long-term DMSO stocks; however, item-specific stability and freeze–thaw tolerance are Not specified for this item and should be validated empirically.
Inspection
Before use, check for precipitation, discoloration, or unexpected odor. Reassess by LC–MS/HPLC if changes are observed.
Note
For definitive stability, solubility, and reconstitution limits for GS-704277, consult the current CoA/Spec Sheet.
Structure and Identity
Brief overview: GS-704277 (SKU G646269) is listed in our small-molecule/compound library category. Structural identifiers are limited in the current product record.
Item-specific (from Product Data)
Product name: GS-704277
SKU: G646269
CAS: 1911579-04-8
PubChem CID: 121313150
InChIKey: 153653 (as provided)
SMILES: Not specified for this item; refer to CoA/Spec Sheet.
Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
Structural features
Specific functional groups, ring systems, and stereochemistry are not disclosed in the Product Data. As such, a 2D structural description cannot be provided here.
Notes
If your workflow requires exact atomic composition or structure (e.g., for LC–MS method development or in silico profiling), please request the current CoA/Spec Sheet or consult the sourcing reference associated with the CAS/CID listed above.
Synthetic Utility
GS-704277 is offered as a screening compound rather than a synthetic reagent.
Item-specific
No functionalities, protecting groups, or reactive handles are disclosed in the Product Data; thus, no reagent-like applications can be specified for this item.
General considerations (if repurposed experimentally; not item-specific)
Some library compounds may contain functional groups amenable to derivatization (e.g., amides, aryl halides, nitriles). If derivatization or probe synthesis is intended, first obtain the full structure and confirm availability of IP rights and permissions.
For use as an analytical or calibration standard, ensure accurate concentration via quantitative NMR or validated UV response factors.
Recommendation
Treat this item primarily as a test article for biological or analytical screening. If synthetic manipulation is planned, request detailed structural data and ensure suitability under the intended reaction conditions.
Target Specificity
Item-specific
Target, mode of action, and selectivity profile: Not specified for this item; refer to CoA/Spec Sheet or primary literature associated with the CAS/CID if needed.
General guidance (screening compounds)
Establish specificity empirically using orthogonal assays, concentration–response analysis, and counterscreens against common off-targets or assay interferences.
Employ selectivity panels and chemoproteomics when feasible. Consider PAINS and aggregator filters, but validate experimentally to avoid false exclusions.
Note
No antigen/epitope/clone information applies; this product is a small molecule, not an antibody or biologic.
Häufig gestellte Fragen
How should this product be stored?
Store at 2–8 °C. Refrigerated storage is required to maintain the specified shelf life.
How is this product shipped?
This product ships chilled on wet ice. Unpack on arrival and transfer it to the storage condition stated above.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is 1911579-04-8, the molecular formula is C15H19N6O8P, and the molecular weight is 442.32 g/mol. InChIKey IYHPTSNEWCZBDF-NIFWRESRSA-N.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.
Wir verwenden Cookies, um die ordnungsgemäße Funktion der Website sicherzustellen und, soweit zulässig, Ihr Nutzererlebnis zu verbessern. Sie können Ihre Einstellungen jederzeit unter „Einstellungen“ verwalten. Weitere Informationen finden Sie in unserer Cookie-Richtlinie.
Dürfen wir Sie über Rabattaktionen informieren?
Später erinnern
Vielen Dank! Bitte überprüfen Sie Ihren E-Mail-Posteingang, um zu bestätigen.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.