HKPerox-1 - ≥99% , CAS No.2240163-05-5

CAS: 2240163-05-5 Cat. No.: H651578 Summenformel: C40H30N2O11 Molekulargewicht: 714.67
Zu bestellen verfügbar
QUALITÄT & REINHEIT ≥99%
Storage
Protected from light,Store at -80°C
Shipped In
Dry ice packs + Cold packs
★
Größe
Deutschland (EU)
USA*
Preis
Menge
1mg
H651578-1mg
Auf Bestellung · 8–12 Wochen
521,42€
5mg
H651578-5mg
Auf Bestellung · 8–12 Wochen
1.562,71€
10mg
H651578-10mg
Auf Bestellung · 8–12 Wochen
2.690,77€
Enter a quantity for the sizes you want to add.

Übersicht

HKPerox-1 is a highly sensitive green fluorescent probe for the specific detection of H 2 O 2 in living cells with a maximum excitation wavelength and emission wavelength of 520 nm and 543 nm, respectively.

In Vitro

1. Preparation of HKPerox-1 working solution 1.1 Preparation of the stock solution Dissolve 1 mg HKPerox-1 in 140 μL DMF to obtain 10 mM of stock solution. Note: It is recommended to store the stock solution at -20℃ -80℃ away from light and avoid repetitive freeze-thaw cycles. 1.2 Preparation of HKPerox-1 working solution Dilute the stock solution in serum-free cell culture medium or PBS to obtain 1-10 μM of working solution. Note: Please adjust the concentration of HKPerox-1 working solution according to the actual situation. 2. Cell staining 2.1 Suspension cells (6-well plate) a. Centrifuge at 1000 g at 4℃ for 3-5 minutes and then discard the supernatant. Wash twice with PBS, 5 minutes each time.The cell density is 1×10 6 /mL b. Add 1 mL of working solution, and then incubate at room temperature for 5-30 minutes. c. Centrifuge at 400 g at 4℃ for 3-4 minutes and then discard the supernatant. d. Wash twice with PBS, 5 minutes each time. e. Resuspend cells with serum-free cell culture medium or PBS.Observation by fluorescence microscopy or flow cytometry. 2.2 Adherent cells a. Culture adherent cells on sterile coverslips. b. Remove the coverslip from the medium and aspirate excess medium. c. Add 100 μL of working solution, gently shake it to completely cover the cells,and then incubate at room temperature for 5-30 minutes. d. Wash twice with medium, 5 minutes each time.Observation by fluorescence microscopy or flow cytometry. MCE has not independently confirmed the accuracy of these methods. They are for reference only.

Form:Solid

Spezifikationen

Spezifikationen & Reinheit
≥99%
Biochemische und physiologische Mechanismen
HKPerox-1 is a highly sensitive green fluorescent probe for the specific detection of H 2 O 2 in living cells with a maximum excitation wavelength and emission wavelength of 520 nm and 543 nm, respectively.
Storage
Protected from light,Store at -80°C
Verschickt in
Dry ice packs + Cold packs
Dieses Produkt erfordert Kühlkettenversand. Grundversand und andere Economy-Optionen sind nicht verfügbar.
Reinheit
≥99%
Product Line
Biologische Produkte
Namen und Kennungen
Molekulargewicht
714.67

Erweiterte Daten

Zertifikate (CoA, COO, BSE/TSE und Analyse-Diagramm)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Chemische und physikalische Eigenschaften
LöslichkeitDMF : 50 mg/mL (69.96 mM; Need ultrasonic)
Lösungsrechner
Bewertungen

Kundenbewertungen

Dürfen wir Sie über Rabattaktionen informieren?

Später erinnern

Vielen Dank! Bitte überprüfen Sie Ihren E-Mail-Posteingang, um zu bestätigen.