QUALITÄT & REINHEITMoligand™?Moligand™ — Aladdin's line of ligands and bioactive small molecules. Use for receptor, pathway, and binding studies needing defined small-molecule tools.
This compound belongs to the class of organic compounds known as phenethylamines. These are compounds containing a phenethylamine moiety, which consists of a phenyl group substituted at the second position by an ethan-1-amine.
External Descriptors
Not available
1. Djoumbou Feunang Y, Eisner R, Knox C, Chepelev L, Hastings J, Owen G, Fahy E, Steinbeck C, Subramanian S, Bolton E, Greiner R, and Wishart DS. ClassyFire: Automated Chemical Classification With A Comprehensive, Computable Taxonomy. Journal of Cheminformatics, 2016, 8:61.
Zertifikate (CoA, COO, BSE/TSE und Analyse-Diagramm)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Chemische und physikalische Eigenschaften
Molekulargewicht
380.9
XLogP3
5.600
Hydrogen Bond Donor Count
0
Hydrogen Bond Acceptor Count
3
Rotatable Bond Count
5
Exact Mass
380.166 Da
Monoisotopic Mass
380.166 Da
Topological Polar Surface Area
29.300 Ų
Heavy Atom Count
27
Formal Charge
0
Complexity
440.000
Isotope Atom Count
0
Defined Atom Stereocenter Count
0
Undefined Atom Stereocenter Count
0
Defined Bond Stereocenter Count
0
Undefined Bond Stereocenter Count
0
The total count of all stereochemical bonds
0
Covalently-Bonded Unit Count
1
Lösungsrechner
Molarity Calculator
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
Bewertungen
Kundenbewertungen
Application Protocols
No tested applications or protocols are provided for this item in the Product Data.
General protocol guidance for small-molecule screening (not item-specific):
Stock solution: Prepare at 10–50 mM in anhydrous DMSO. Record exact concentration by weight-in or by qNMR if high precision is required.
Working solutions: Dilute into assay buffer or media to final DMSO ≤0.5–1% v/v. Include vehicle controls and, if appropriate, positive control ligands.
Plate handling: Store source plates at room temperature desiccated or at 4 °C, minimize light exposure for photosensitive compounds, and avoid repeated freeze–thaw cycles.
Quality control: Pre-screen for aggregation (e.g., detergent control, DLS), redox cycling, and autofluorescence.
Item-specific assay conditions and recommended dilutions: Not specified for this item; refer to CoA/Spec Sheet or develop empirically.
Biological Roles
Item-specific biological information: Not specified for this item; refer to CoA/Spec Sheet and SDS. No target, pathway, or mechanism data are provided in the Product Data.
General guidance for small-molecule library members (not item-specific):
Potential roles: May act as enzyme inhibitors/activators, receptor ligands, ion channel modulators, or pathway probes depending on structure and stereochemistry.
Assay considerations: Evaluate aggregated behavior (use detergent controls), redox activity, metal chelation, and intrinsic fluorescence/absorbance to flag assay interference.
ADME-relevant properties: If data become available (cLogP, pKa, TPSA), they can inform permeability, solubility, and non-specific binding—useful for interpreting cellular assay results.
PAINS/REOS filters: Before biological deployment, screen the structure (when available) against PAINS, Brenk, and other substructure filters to reduce false positives.
Stability: Assess chemical and metabolic stability in relevant media (buffer, microsomes) if the compound advances beyond primary screening.
Note: No clinical or therapeutic claims are made. This product is for research use only, as stated by the manufacturer.
Buffer Applications
This section is generally not applicable to unspecified small-molecule library members lacking acid/base characterization. Without pKa, solubility, and functional group data, buffer system recommendations (pH range, recipes) cannot be made item-specifically.
Practical guidance (general):
If the compound contains ionizable groups (once confirmed), choose buffer pH within ±1 of the relevant pKa to optimize solubility.
Common assay buffers: PBS, HEPES, Tris, or acetate. Maintain final DMSO ≤0.5–1% v/v to limit biological interference.
Always validate compound stability in the chosen buffer over the assay timeframe (e.g., 1–24 h) by LC–MS.
Item-specific buffer suitability: Not specified for this item; refer to CoA/Spec Sheet and determine experimentally.
Green Alternatives
Item-specific solvent/processing data: Not specified for this item; refer to CoA/Spec Sheet.
General sustainability considerations for small-molecule handling (not item-specific):
Stock preparation: Favor lower-toxicity solvents where feasible. While DMSO is common, ethanol or aqueous buffers (adjusted pH) can be used if solubility and stability allow.
Analytical methods: Use UHPLC to reduce solvent volumes; prefer ACN over halogenated solvents when chromatographically suitable. Recycle ACN/MeOH with in-house purification where permitted.
Reactions/derivatizations (if pursued): Consider greener media such as 2-MeTHF, CPME, water/ethanol, or propylene carbonate instead of DMF/NMP/halogenated solvents—balanced against solubility and selectivity needs.
Illustrative comparison (general, not item-specific):
Traditional: DMF/NMP (excellent solvation; reproductive toxicity concerns; high E-factor in workups).
Greener options: 2-MeTHF/CPME (bio-derived, lower peroxide tendency than ethers like THF, improved phase separation); water–ethanol systems (safe, scalable) when the chemistry allows.
Trade-offs:
Greener solvents may alter reaction rates/selectivity or analyte retention in LC. Validate methods with your compound and document any changes in performance.
Because the exact chemistry of this item is unspecified, select alternatives using solvent selection guides (e.g., CHEM21, GSK, ACS green solvent guides) and empirical solubility/stability screens.
Pharmaceutical Uses
No pharmacopeial status, excipient role, or formulation information is provided for this item. As supplied, it is part of a small-molecule/compound library and is designated For research use only.
General, non-clinical context (not item-specific):
Early discovery: Such compounds are typically used for HTS, hit validation, and SAR exploration, not for human or veterinary use.
Preformulation studies (if pursued in research): Determine polymorph, hygroscopicity, and solution stability; characterize solubility across biorelevant media. These activities remain strictly research-stage and are not therapeutic claims.
Regulatory: Not intended for use in diagnostics, foods, or drugs. No GMP/USP/EP grading inferred unless explicitly stated on the CoA.
Item-specific pharmaceutical applications: Not specified for this item; refer to CoA/Spec Sheet if any regulatory or formulation notes are available.
Physical Properties
Item-specific properties from Product Data:
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
Molecular Weight: Not specified for this item; refer to CoA/Spec Sheet.
Computed/literature values:
Due to missing structure (SMILES/InChI) and confirmed formula, no reliable computed or literature physical constants (bp, mp, density, logP, pKa, refractive index, UV cutoff) can be reported here without risking misidentification. Consult the SDS/CoA for batch-specific values.
General guidance for small-molecule library materials (not item-specific):
Solid vs liquid: Many screening compounds are crystalline or amorphous solids with mp typically >60 °C (literature, general). Liquids may occur for low-MW or aliphatic species.
Solubility considerations: For assay stock preparation, DMSO is commonly used at 10–50 mM; water miscibility depends on ionizable groups (assess by pKa) and salt form (literature, general). Co-solvents (DMF, ethanol) can assist dissolution.
Hygroscopicity/polymorphism: Library compounds may be mildly hygroscopic or exist in multiple forms; verify mass balance by drying under vacuum at ambient–40 °C if compatible.
Spectral characterization: Typical 1H NMR in DMSO-d6 or CDCl3, LC–MS for purity/RT; ensure UV spectra if planning HPLC-UV quantitation.
Important: For any parameter needed for method validation (mp, solubility limit, extinction coefficient), obtain item-specific data from CoA/Spec Sheet or determine experimentally with the ordered lot.
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
What Moligand™ generally implies (general description; not a specification):
Intended use: Research-use small molecules suitable for screening, hit validation, and probe development workflows—typically provided with identity confirmation (e.g., LC–MS) and library-friendly packaging.
Purity characterization: Library-grade compounds are commonly qualified by LC–MS/UPLC with UV or ELSD detection; target purity thresholds vary by supplier and project stage. Item-specific purity, residual solvents, water content, metals, or stabilizers are Not specified for this item; refer to CoA/Spec Sheet.
Documentation: CoA often includes structure, MW, salt form, analytical purity, and chromatographic conditions. Request batch CoA for your lot.
Implications for research: For biochemical or cell-based assays, confirm absence of interfering UV/fluorescent impurities and verify solubility in DMSO at target stock concentrations.
Best practices to qualify your lot (recommendations):
Run orthogonal purity checks (LC–MS with two orthogonal gradients; 1H NMR qNMR for wt%).
Verify salt/hydrate state and correct for assay molarity.
Record stability in your diluent (DMSO/water) at room temperature and 4 °C across assay timelines.
Reaction and Applications
Manufacturer Applications (verbatim): Not provided in Product Data.
Context for this category (general, not item-specific):
Category indicates a small molecule within a compound library (小分子和化合物库). Such materials are typically used for high-throughput screening (HTS), fragment-based discovery, chemical biology probing, and SAR expansion rather than as bulk reagents.
Potential laboratory applications (general):
Screening/profiling: Evaluate biochemical target engagement, phenotypic effects, or selectivity panels.
Chemical biology: Use as a putative probe scaffold; append tags (biotin/alkyne) via suitable handles if present.
Method development: If functional groups permit, derivatize to explore potency/SAR; leverage parallel synthesis.
Practical tips (generic):
Confirm identity and purity prior to screening to reduce false positives/PAINS. Use orthogonal LC–MS and NMR.
Prepare fresh DMSO stocks; filter (0.2 µm PTFE) if particulates are observed. Avoid freeze–thaw cycling to maintain integrity.
If reactivity is unknown, store away from strong light and moisture; test stability in assay buffer over experimental time.
Important: Because the precise structure is not supplied here, do not assume compatibility with particular reaction families (e.g., cross-coupling, nucleophilic substitutions). Design transformations only after verifying functional groups from CoA/SDS or analytical data.
Reaction Conditions
Item-specific reaction conditions: Not specified for this item; refer to CoA/Spec Sheet and primary literature for the confirmed structure.
General guidance (not item-specific):
Cross-couplings: Typical conditions (literature) include Pd catalysts (e.g., Pd(PPh3)4, Pd2(dba)3/XPhos), bases (K2CO3, Cs2CO3), solvents (2-MeTHF, toluene, dioxane, CPME), 60–110 °C, 2–16 h.
Reductive amination: NaBH3CN or BH3·THF, MeOH/AcOH or DCE/DIPEA, 0–25 °C then warm to rt, 2–6 h.
Amide coupling: HATU or EDCI/HOBt alternatives (Oxyma), DIPEA, DMF/MeCN/2-MeTHF, rt–40 °C, 1–12 h.
Photoredox: Ir(ppy)3 or 4CzIPN, blue LEDs, MeCN/MeOH, rt, 2–24 h.
Hydrogenation: Pd/C (5–10%), EtOH/EtOAc, 1–5 bar H2, rt–50 °C.
Analytical controls:
Monitor by LC–MS and TLC; confirm conversion and check for over-reaction. Validate workup compatibility with the scaffold.
Caveat: Apply only after confirming that the functional groups present on this specific item tolerate the selected conditions. Absent structure, these are illustrative literature conditions, not recommendations for this item.
Safety and Handling
Item-specific hazard information from Product Data:
Signal Word: Not specified for this item; refer to SDS.
H-Statements: Not specified for this item; refer to SDS.
GHS Classification/Pictograms: Not specified for this item; refer to SDS.
Storage Conditions: Room temperature (as provided). Confirm stability for your application.
General laboratory safety (not item-specific; defer to SDS as authoritative):
PPE: Wear lab coat, safety glasses, and appropriate chemically resistant gloves (e.g., nitrile). Use in a fume hood to minimize inhalation of any dusts/vapors.
Avoid: Incompatible reagents will depend on functional groups (oxidants/reductants, acids/bases). Until identity hazards are known, segregate from strong oxidizers and acids/bases by default and keep away from ignition sources.
Handling: Minimize exposure; avoid aerosolization. For solids, weigh in a ventilated balance enclosure if fine particulate is expected.
First aid (generic): Inhalation—move to fresh air; Skin—wash with soap/water; Eyes—rinse with water for ≥15 min; Ingestion—seek medical attention. Provide SDS to responders.
Spill/containment: For small spills, absorb with inert material; avoid discharge to drains. Dispose according to institutional and local regulations.
Special risks: Unknown for this specific item. Until confirmed, treat as potentially harmful if swallowed, inhaled, or in contact with skin. Assume potential environmental hazard and prevent release.
Always consult the product’s SDS and your institution’s EHS guidelines before use.
Solvent Selection
Item-specific solvent data: Not specified for this item; refer to CoA/Spec Sheet.
General guidance for small-molecule library compounds (not item-specific):
Primary solvent for stocks: DMSO is the de facto choice for 10–50 mM stocks due to broad solubilizing power and assay compatibility at ≤0.5–1% v/v in wells.
Secondary solvents: DMF or NMP (for low-volatility needs), and volatile co-solvents (acetonitrile, methanol, ethanol) for analytical sample prep.
Aqueous compatibility: Determine ionization via pKa (if available) to guide buffer pH for dissolution. Salts (HCl/TFA, Na+) may improve aqueous solubility.
Analytical chromatography: Start with ACN/water + 0.1% formic acid for LC–MS ESI+. Switch to MeOH/water or ammonium bicarbonate for alternative ionization/retention.
Incompatibilities: Avoid strong bases with ester/halide-containing molecules; avoid strong acids for acid-labile moieties (acetals, Boc). For thiols/aldehydes, minimize air/oxidants.
Decision workflow (practical):
Attempt dissolution at 10 mM in anhydrous DMSO; sonicate gently if needed.
If insoluble, warm to 40 °C briefly or dilute to 1–5 mM; consider DMF or NMP.
For aqueous assays, titrate DMSO stock into buffered media; keep final DMSO ≤0.5% v/v if possible.
For NMR, select DMSO-d6 or CDCl3 depending on polarity; add TFA-d for basic amines to sharpen signals.
Note: Because structure is not provided here, determine solvent by a small solubility screen and document conditions with your lot.
Storage and Reconstitution
Item-specific information from Product Data:
Storage Conditions: Room temperature.
Shipped In: Not specified for this item; refer to CoA/Spec Sheet.
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
General best practices (not item-specific):
On receipt: Inspect packaging for integrity. If a solid, keep tightly capped with desiccant; if a solution, verify concentration and solvent.
Long-term storage: Unless otherwise stated on the CoA, store in a cool, dry place protected from light. For potentially air/moisture-sensitive compounds, consider inert-atmosphere storage (argon) and secondary containment with desiccant.
Reconstitution: For assay use, dissolve in anhydrous DMSO to prepare 10–50 mM stocks. Vortex/sonicate briefly; warm gently (≤40 °C) if needed. Filter through 0.2 µm PTFE if particulates persist.
Aliquoting: Dispense single-use aliquots to avoid repeated freeze–thaw or evaporation–reconstitution cycles. Record exact mass and final volume for traceability.
Stability tracking: Document storage temperature, light exposure, and any observed degradation (color change, precipitation). Periodically re-check by LC–MS.
Any item-specific stabilizers, water/peroxide/metal limits, or shelf-life: Not specified for this item; refer to CoA/Spec Sheet.
Research Use Note: For research use only.
Structure and Identity
Item-specific identifiers from Product Data:
SKU: L611409
Product Name: L741742
CAS: 156337-32-5
PubChem CID: 133008
InChIKey: 294088 (note: this appears non-standard/abbreviated; verify against CoA/SDS)
SMILES: Not specified for this item; refer to CoA/Spec Sheet.
Molecular Formula: Not specified for this item; refer to CoA/Spec Sheet.
Molecular Weight: Not specified for this item; refer to CoA/Spec Sheet.
Structural features:
Item-specific functional groups, ring systems, and stereochemistry: Not specified for this item; refer to CoA/Spec Sheet.
2D structure description (general guidance):
Without the SMILES/InChI, a definitive 2D structural description cannot be provided. Please consult the certificate of analysis (CoA), SDS, or authoritative databases (cross-reference CAS 156337-32-5 and CID 133008) to confirm atom connectivity, ring count, heteroatoms, and any stereocenters prior to method development or hazard assessment.
Notes for identity confirmation (general best practice):
Cross-check CAS, CID, and supplier batch labels.
Acquire orthogonal identity data where feasible: 1H/13C NMR, HRMS (ESI/APCI as appropriate), and LC–MS RT versus a reference.
If chirality is possible, verify enantiomeric/diastereomeric purity by chiral HPLC or derivatization methods.
For screening-library compounds, confirm salt form (free base/acid vs. HCl/TFA salt) and hydration/solvation state, as these affect MW and assay concentrations.
Synthetic Utility
Item-specific functional group reactivity and named-reaction suitability: Not specified for this item; refer to CoA/Spec Sheet.
General possibilities for small-molecule library members (not item-specific):
If equipped with cross-coupling handles (aryl halide, boronate, vinyl triflate), the scaffold can be diversified via Suzuki–Miyaura, Buchwald–Hartwig, or Sonogashira couplings.
If bearing carbonyls (acid/ester/amide/ketone), options include amidation, reductive amination, olefination, or late-stage functionalizations (e.g., photoredox α-alkylations) depending on compatibility.
If containing heteroatoms (N/O/S), protection–deprotection strategies and site-selective derivatizations enable SAR panels and probe attachment (alkyne/azide for CuAAC).
Practical tips (general):
Verify the exact substitution pattern and oxidation state from CoA before planning transformations.
Consider orthogonal protecting groups to preserve sensitive motifs during diversification.
For library resynthesis, design routes amenable to parallel chemistry and purification by automated flash or preparative LC.
Because the exact structure is not provided, treat these options as hypothetical until the functional groups of this specific item are confirmed.
Target Specificity
No target, epitope, clone, or species reactivity information is provided for this product. This is not an antibody or biologic; it is listed within a small-molecule/compound library.
Item-specific target data: Not specified for this item; refer to CoA/Spec Sheet or screening reports if available.
Häufig gestellte Fragen
What is Moligand??
Moligand? is one of Aladdin Scientific's premium product lines, formulated for high-purity applications across multiple workflows. Compared to standard grades in the same workflow, Moligand? products typically offer tighter specifications, more rigorous QC, and stronger lot-to-lot consistency.
How should this product be stored?
Store at room temperature.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is 156337-32-5. InChIKey QDMAKDIDFJTXEL-UHFFFAOYSA-N.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.
Benötigen Sie Hilfe bei der Auswahl der Qualität?
Unser Leitfaden zur Qualitätsauswahl behandelt Reinheit, Stabilisatorstatus und Anwendungseignung für alle Varianten in unserem Katalog.
Wir verwenden Cookies, um die ordnungsgemäße Funktion der Website sicherzustellen und, soweit zulässig, Ihr Nutzererlebnis zu verbessern. Sie können Ihre Einstellungen jederzeit unter „Einstellungen“ verwalten. Weitere Informationen finden Sie in unserer Cookie-Richtlinie.
Dürfen wir Sie über Rabattaktionen informieren?
Später erinnern
Vielen Dank! Bitte überprüfen Sie Ihren E-Mail-Posteingang, um zu bestätigen.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.