LS Columns - BioReagent,sterile

Cat. No.: L1520103
AVAILABLE TO ORDER
GRADE & PURITY BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. Sterile ? Sterile grade — processed and verified free of viable microorganisms. Use directly in aseptic procedures and cell culture without further sterilization.
Synonyms
gL Columns
Storage
Room temperature
Shipped In
Normal
Application
Cell analysis
Size
USA
Germany (EU)*
Price
Qty
1EA
L1520103-1EA
US Made to order · 2–4 wks ·
$39.90
25EA
L1520103-25EA
US Made to order · 2–4 wks ·
$369.90
Enter a quantity for the sizes you want to add.
🧪

Why this grade

BioReagent,sterile BioReagent,Sterile for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Room temperature Ships Normal Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

Overview

Cell separation column is a specialized consumable designed for column-based cell sorting, developed specifically for the gentle isolation of cells labeled with nanomagnetic beads. Due to the extremely small size of the cell separation nanomagnetic beads (particle size: 50–100 nm), a high-intensity magnetic field is required to attract the labeled cells. The column contains an optimized matrix that, when used with a magnetic separation system, amplifies the magnetic field nearly ten-thousand-fold, enabling efficient capture and gentle elution of magnetically labeled cells. It is widely used for cell enrichment, depletion, and sorting in research and preclinical stages.



Cat. No.
Product Name
Max. Load of Labeled Cells
Max. Total Cell Load
M1520097MS Columns
1× 10⁷
2× 10⁸
L1520103LS Columns
1× 10⁸
2× 10⁹

Note: When isolating cells larger than lymphocytes, the column capacity may be reduced.



Procedure

1. Column Preparation

(1) Column installation: Insert the separation column into a suitable magnetic stand, ensuring the column wings face forward. Place a collection tube at the column outlet.

(2) Column priming: Add 2 mL of separation buffer to the column and allow it to flow through naturally.

(3) Discard flow-through: Replace the collection tube. The column is now ready.


2. Magnetic Separation

Magnetic labeling must be performed before magnetic separation. Refer to the nanomagnetic bead instructions for specific labeling methods.

(1) Cell suspension preparation: Resuspend cells in separation buffer, using 500 μL of buffer per 10⁸ cells.

Note: For higher cell numbers, increase the buffer volume accordingly.


(2) Sample loading: Apply the cell suspension to the prepared column. Collect the flow-through containing unlabeled cells.


(3) Washing: Wash the column three times with 2 mL of separation buffer. Collect the unlabeled cells that pass through and combine them with the flow-through from step (2).

Note: Once the column reservoir is empty, immediately add the same volume of buffer for the washing steps.


(4) Remove the column and place it on a new collection tube.


(5) Elution: Add 5 mL of separation buffer to the column and use the supplied plunger to quickly elute the magnetically labeled cells.

Note: (Optional) To improve the purity of magnetically labeled cells, the eluted cells can be passed through a second LS column for re-sorting.



Precautions

  1. The LS columns and matching plunger are supplied individually in sterile packaging. They are intended for single use and reuse is not recommended.

  2. Prepare the separation buffer before the experiment: PBS (pH 7.2), 0.5% BSA, and 2 mM EDTA. Mix thoroughly and store at 4 °C.

  3. Due to differences in samples and research objectives, optimal experimental conditions should be determined by the user.

  4. This product is for research use only.

  5. For your safety and health, please wear a lab coat and disposable gloves during operation.

Specifications

Synonyms
gL Columns
Specifications & Purity
BioReagent, sterile
Stability And Storage
Store at room temperature long term (24 months).
Storage
Room temperature
Shipped In
Normal
Grade
BioReagent, Sterile

Documentation

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Certificates(CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

2 results found

Lot NumberCertificate TypeDateItem
ZJ26F0434829Certificate of AnalysisApr 29, 2026 L1520103
ZJ26F0434724Certificate of AnalysisApr 27, 2026 L1520103
Documents & Articles
Solution Calculators
Reviews

Customer Reviews

Need help choosing the grade?

Our grade selection guide covers purity, stabilizer status, and application suitability for all variants in our catalog.

View BioReagent grade guide → View Sterile grade guide →

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.