Methsuximide-d5 - ≥98 atom% D,≥98% , CAS No.1189980-63-9

CAS: 1189980-63-9 Cat. No.: M345476 Summenformel: C12H8D5NO2 Molekulargewicht: 208.27
Zu bestellen verfügbar
QUALITÄT & REINHEIT ≥98 atom% D,≥98%
Synonyms
Methsuximide-d5|1,3-Dimethyl-3-(phenyl-d5)-2,5-pyrrolidinedione|1,3-dimethyl-3-(2,3,4,5,6-pentadeuteriophenyl)pyrrolidine-2,5-dione|1,3-Dimethyl-3-(~2~H_5_)phenylpyrrolidine-2,5-dione|1,3-dimethyl-3-[(2,3,4,5,6-(2)H)phenyl]pyrrolidine-2,5-dione|(+/-)-Mesuximide-d5
Storage
Store at 2-8°C
Shipped In
Wet ice
★
Größe
Deutschland (EU)
USA*
Preis
Menge
1mg
M345476-1mg
Auf Bestellung · 8–12 Wochen
357,42€
5mg
M345476-5mg
Auf Bestellung · 8–12 Wochen
1.251,19€
Enter a quantity for the sizes you want to add.

Übersicht

Application:

A labelled calcium channel succinimide antiepileptic drug. Anticonvulsant.

Spezifikationen

Synonyme
Methsuximide-d5 | 1,3-Dimethyl-3-(phenyl-d5)-2,5-pyrrolidinedione | 1,3-dimethyl-3-(2,3,4,5,6-pentadeuteriophenyl)pyrrolidine-2,5-dione | 1,3-Dimethyl-3-(~2~H_5_)phenylpyrrolidine-2,5-dione | 1,3-dimethyl-3-[(2,3,4,5,6-(2)H)phenyl]pyrrolidine-2,5-dione | (+/-)-Mesuximide-d5
Spezifikationen & Reinheit
≥98 atom% D,≥98%
Storage
Store at 2-8°C
Verschickt in
Wet ice
Dieses Produkt erfordert Kühlkettenversand. Grundversand und andere Economy-Optionen sind nicht verfügbar.
Reinheit
≥98 atom% D,≥98%
Namen und Kennungen
SMILES
CC1(CC(=O)N(C1=O)C)C2=CC=CC=C2
IUPAC Name
1,3-dimethyl-3-(2,3,4,5,6-pentadeuteriophenyl)pyrrolidine-2,5-dione
InChIKey
AJXPJJZHWIXJCJ-DKFMXDSJSA-N
InChI
1S/C12H13NO2/c1-12(9-6-4-3-5-7-9)8-10(14)13(2)11(12)15/h3-7H,8H2,1-2H3/i3D,4D,5D,6D,7D
Isomere SMILES
[2H]C1=C(C(=C(C(=C1[2H])[2H])C2(CC(=O)N(C2=O)C)C)[2H])[2H]
Alternative CAS-Nummer
77-41-8
Molekulargewicht
208.27
Reaxys
168315
Reaxys-RN_link_address
https://www.reaxys.com/reaxys/secured/hopinto.do?context=S&query=IDE.XRN=168315&ln=

Erweiterte Daten

Taxonomic Classification

Taxonomy Tree

KingdomOrganic compounds
SuperclassOrganoheterocyclic compounds
KlassePyrrolidines
SubclassPhenylpyrrolidines
Intermediate Tree Nodes Not available
Direct ParentPhenylpyrrolidines
Alternative Parents Pyrrolidine-2-ones  N-substituted carboxylic acid imides  N-alkylpyrrolidines  Benzene and substituted derivatives  Pyrroles  Dicarboximides  Tertiary amines  Lactams  Amino acids and derivatives  Azacyclic compounds  Organic oxides  Hydrocarbon derivatives  Carbonyl compounds  
Molecular FrameworkAromatic heteromonocyclic compounds
Substituents 3-phenylpyrrolidine - Monocyclic benzene moiety - Carboxylic acid imide, n-substituted - Pyrrolidone - 2-pyrrolidone - N-alkylpyrrolidine - Benzenoid - Carboxylic acid imide - Dicarboximide - Pyrrole - Tertiary amine - Lactam - Amino acid or derivatives - Azacycle - Carboxylic acid derivative - Organic nitrogen compound - Amine - Carbonyl group - Organic oxide - Organic oxygen compound - Hydrocarbon derivative - Organooxygen compound - Organonitrogen compound - Aromatic heteromonocyclic compound
BeschreibungThis compound belongs to the class of organic compounds known as phenylpyrrolidines. These are polycyclic aromatic compounds containing a benzene ring linked to a pyrrolidine ring through a CC or CN bond. Pyrrolidine is a five-membered saturated aliphatic heterocycle with one nitrogen atom and four carbon atoms.
External Descriptors Not available
3D-Struktur
Interaktives chemisches Strukturmodell





Zertifikate (CoA, COO, BSE/TSE und Analyse-Diagramm)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Chemische und physikalische Eigenschaften
LöslichkeitChloroform (Slightly), Methanol (Slightly, Sonicated)
Molekulargewicht208.27
XLogP31.200
Hydrogen Bond Donor Count0
Hydrogen Bond Acceptor Count2
Rotatable Bond Count1
Exact Mass208.126 Da
Monoisotopic Mass208.126 Da
Topological Polar Surface Area37.400 Ų
Heavy Atom Count15
Formal Charge0
Complexity294.000
Isotope Atom Count5
Defined Atom Stereocenter Count0
Undefined Atom Stereocenter Count1
Defined Bond Stereocenter Count0
Undefined Bond Stereocenter Count0
The total count of all stereochemical bonds0
Covalently-Bonded Unit Count1
Sicherheit und Gefahren (GHS)
Signal
Warning
Gefahrenhinweise

H302:Harmful if swallowed

Sicherheitshinweise

P264:Wash hands [and …] thoroughly after handling.

P270:Do not eat, drink or smoke when using this product.

Reaxys
168315
Reaxys-RN_link_address
https://www.reaxys.com/reaxys/secured/hopinto.do?context=S&query=IDE.XRN=168315&ln=
Lösungsrechner
Bewertungen

Kundenbewertungen

Application Protocols

No item-specific, validated protocols are provided in the Product Data. The following outlines a typical LC–MS/MS internal standard workflow for small-molecule quantification (general guidance; adjust to your method and instrumentation):

  • Preparation of standards and QCs:

    • Prepare Methsuximide-d5 stock in MeOH or ACN (e.g., 1 mg/mL). Prepare analyte (unlabeled) stock similarly.
    • Serially dilute analyte to create a calibration series in blank matrix extract or surrogate matrix. Add a fixed concentration of Methsuximide-d5 to all standards, QCs, and unknowns.
  • Sample preparation (protein precipitation example):

    • Add internal standard working solution to biological matrix (e.g., plasma) at a defined volume.
    • Precipitate proteins with ≥3 volumes of cold ACN or MeOH containing the internal standard; vortex and centrifuge.
    • Transfer supernatant, dilute with aqueous mobile phase if necessary, and inject.
  • LC–MS/MS conditions (to be optimized):

    • Column: C18 or phenyl-hexyl, sub-3–5 µm.
    • Mobile phase A: water + 0.1% formic acid (or ammonium formate/acetate 2–10 mM).
    • Mobile phase B: ACN or MeOH.
    • Monitor transitions for the unlabeled analyte and the +5 Da isotopologue; verify absence of cross-talk and isotopic overlap.
  • Quality controls: Include low/mid/high QCs, matrix effect, recovery, carryover checks, and stability assessments.

Refer to the item’s CoA/SDS for any lot-specific instructions or restrictions.

Biological Roles

No biological roles are assigned to Methsuximide-d5 beyond its function as a research tool. This product is intended strictly for research use (per Product Data: For research use only) and is not for human or animal therapeutic or diagnostic use.

Context (general, literature):

  • The parent compound, methsuximide, belongs to the succinimide class of small molecules. Deuterated analogs are typically biologically equivalent in mechanism but are employed at trace levels as internal standards rather than for biological effect.
  • In biochemical and pharmacokinetic research, deuterated internal standards facilitate accurate quantification of the unlabeled analyte in complex matrices, enabling studies of absorption, distribution, metabolism, and excretion of the parent compound without invoking any pharmacological effect from the labeled standard.

Practical implications:

  • When used in bioanalytical workflows, Methsuximide-d5 is spiked at low, known concentrations to correct for matrix effects and procedural losses.
  • Because the label is non-radioactive and, for typical d5 implementations, on non-exchangeable positions, it is suitable for routine LC–MS/MS assays without isotopic scrambling under standard conditions (verify labeling pattern on the CoA for your lot).

Note: Avoid inferring any clinical efficacy or biological activity from the presence of the deuterium label; its role here is analytical normalization only.

Buffer Applications

This product is not a buffering agent and is not typically used to prepare biochemical buffer systems. For analytical workflows, buffers are relevant only as components of the LC–MS mobile phase or sample diluents.

General guidance (analytical context):

  • LC–MS mobile phases: volatile buffers such as 2–10 mM ammonium formate or ammonium acetate with 0.1% formic or acetic acid are commonly used. Select pH and buffer strength to optimize signal and peak shape for the parent methsuximide analyte.
  • Sample preparation: if dilution into aqueous buffer is required, keep organic content consistent with calibrators and control the pH to avoid imide hydrolysis (generally avoid strong base).
Green Alternatives

As a deuterated analytical standard, Methsuximide-d5 itself is not typically substituted. However, greener choices can be made for solvents and sample-preparation workflows used with this standard.

Greener solvent choices (general; literature-based greenness rankings):

  • Methanol vs acetonitrile: Methanol is often considered greener (renewable feedstock potential, lower toxicity), but ACN can deliver superior chromatographic performance. Balance safety, waste minimization, and performance.
  • Ethanol (anhydrous, LC-compatible): In some methods, ethanol can replace methanol for stock solutions; verify solubility and chromatographic impact.
  • Aqueous-rich mobile phases: Optimize gradient and column chemistry to increase water proportion while maintaining resolution.

Process considerations:

  • Miniaturize assays (microextraction, low-volume injections) to reduce solvent consumption.
  • Prefer protein precipitation with minimal organic solvent or micro-SPE formats over large-volume LLE when method sensitivity allows.
  • Implement solvent recovery where feasible and segregate halogenated from non-halogenated waste streams.

Trade-offs:

  • Lower-toxicity solvents may change elution strength and ionization efficiency; method re-optimization (gradient, source parameters) may be required.
  • Stability: Confirm that alternative solvents do not compromise the integrity of the imide scaffold or the isotopic label (verify by test injections/HRMS).
Pharmaceutical Uses

No excipient or pharmacopeial status is provided for Methsuximide-d5 in the Product Data. This product is designated for research use only and is commonly employed as an analytical reference/internal standard in pharmaceutical and biopharmaceutical R&D and QC laboratories.

Typical roles (general, non-clinical):

  • Internal standard for assay development: supports quantification of methsuximide in stability studies, impurity profiling, dissolution testing extracts, and bioanalytical sample sets.
  • Process and formulation analytics: used to correct for extraction recovery and matrix effects when measuring the parent drug in development samples.
  • Method validation: applied across calibration curves, QC samples, and incurred sample reanalysis to demonstrate accuracy and precision per regulatory guidance (general practice).

Regulatory note:

  • Deuterated internal standards are widely used in GMP/GLP settings for analytical purposes; however, their own pharmacopeial monographs are uncommon. Lot-specific documentation (CoA, isotopic enrichment data, purity) should be retained within the analytical method file.

Any medicinal/therapeutic claims are outside the scope of this product and are not implied.

Physical Properties

No item-specific physico-chemical specifications are provided in the Product Data for this deuterated standard.

  • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
  • Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.
  • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
  • Solubility: Not specified for this item; refer to CoA/Spec Sheet.
  • Melting point / Boiling point: Not specified for this item; refer to CoA/Spec Sheet.
  • Density / refractive index / logP / pKa: Not specified for this item; refer to CoA/Spec Sheet.

Literature/contextual guidance (for the parent methsuximide; for planning only):

  • Methsuximide (unlabeled) is a moderately lipophilic succinimide commonly soluble in polar organic solvents such as methanol, acetonitrile, and DMSO, with limited aqueous solubility (literature/general). Deuteration (d5) does not materially change bulk properties for analytical use, though very small shifts in retention time or vapor pressure can occur (isotope effect; literature).

Practical note:

  • For LC–MS internal standard solutions, analysts typically prepare stock solutions in high-purity methanol, acetonitrile, or DMSO, then dilute into aqueous mobile phase containing organic modifier immediately prior to use (general analytical practice). Confirm actual solubility and concentration limits with the item-specific CoA.
Quality and Grades

Item-specific grade, purity, and isotopic enrichment are not provided in the Product Data.

  • Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.
  • Isotopic enrichment (D): Not specified for this item; refer to CoA/Spec Sheet.

Guidance on interpreting deuterated standard quality (general):

  • Isotopic enrichment: For quantitative LC–MS/MS, typical enrichments are ≥98 atom % D at labeled positions to minimize interference from unlabeled analog. Confirm exact enrichment and labeling pattern on the CoA.
  • Chemical purity: High chemical purity minimizes background signals and adducts; look for low related impurities and residual solvents on the CoA.
  • Residual protic solvents/water: May be relevant if exchangeable deuterium is present; for non-exchangeable labels, impact is mainly on weighing accuracy.
  • Intended use: “For research use only” (per Product Data). Suitable for analytical standardization, method development, and isotope-dilution studies in research and QC contexts.
  • Documentation: Each lot’s CoA typically includes isotopic pattern (HRMS), chromatographic purity, and, where applicable, NMR data confirming labeling.

Stabilizers: Not specified for this item; refer to CoA/Spec Sheet. If present, stabilizers can affect UV background or MS baselines; adjust methods accordingly.

Reaction and Applications

Primary use is analytical: Methsuximide-d5 serves as a stable-isotope internal standard for quantitative determination of methsuximide (and possibly its related metabolites) by LC–MS/MS or GC–MS.

  • Key applications (research/QC; general):

    • Isotope-dilution mass spectrometry: corrects for extraction efficiency, ion suppression, and instrument variability by co-elution with the native analyte.
    • Method development and validation: used to establish linearity, accuracy, precision, matrix effects, and recovery in bioanalytical assays (plasma/serum/urine or formulation matrices) per regulatory guidance (e.g., ICH, FDA bioanalytical method validation; general context).
    • Recovery studies and spiking experiments: evaluation of sample preparation procedures such as protein precipitation, LLE, or SPE.
  • Practical tips:

    • Prepare a master stock at a precisely known concentration in MeOH or ACN; verify by weight and, where possible, independent UV or MS assay.
    • Store aliquots at 2–8°C (per Product Data) or below; minimize freeze–thaw cycles and light exposure.
    • Match concentration and solvent composition of the internal standard solution to the calibration standards to maintain consistent matrix and injection conditions.
    • If labeling pattern is on non-exchangeable positions (typical for d5 standards), isotopic integrity is robust; nonetheless, avoid strongly protic/basic conditions that could induce imide hydrolysis (general).
  • Secondary uses (research):

    • Tracer studies and kinetic isotope effect probes in imide-containing systems (general experimental design).
Reaction Conditions

No specific reaction conditions are prescribed for Methsuximide-d5 since it is intended as an analytical internal standard rather than a reagent. The following guidance applies to its use in analytical sample preparation (general practice):

  • Stock solution preparation: dissolve accurately weighed material in LC–MS grade methanol or acetonitrile to 0.1–1.0 mg/mL (or as required). Vortex until fully dissolved; sonication may be employed if needed. Filter through 0.2 µm PTFE only if particulate is visible.
  • Working solutions: dilute in mobile phase or 50:50 aqueous buffer/organic (MeOH or ACN). Maintain organic composition similar to calibrators and samples to minimize solvent effects.
  • Sample spiking: add internal standard before extraction (protein precipitation, LLE, or SPE) to correct for recovery and matrix effects.
  • Stability checks: evaluate bench-top (4–8 h), autosampler (4–24 h at 4–10°C), and freeze–thaw stability using replicate QC levels; acceptance criteria per your method validation plan (general regulatory guidance).

Literature-based considerations (parent imide chemistry):

  • Avoid prolonged exposure to strong bases (e.g., >0.1 M hydroxide) which can hydrolyze imides.
  • Mildly acidic mobile phases (e.g., 0.1% formic acid) are commonly compatible with LC–MS/MS of succinimides; optimize depending on ionization polarity.

Note: Yields, catalysts, or named-reaction parameters are not applicable here.

Safety and Handling

GHS/SDS data are not provided in the Product Data for this item. Handle according to good laboratory practice and consult the product-specific SDS prior to use.

  • GHS classification: Not specified for this item; refer to SDS.
  • Signal word / H-statements / pictograms: Not specified for this item; refer to SDS.

General safety guidance (non-authoritative; follow SDS):

  • PPE: Use appropriate lab coat, safety glasses, and chemical-resistant gloves. Employ handling in a fume hood when preparing concentrated stock solutions or weighing powders.
  • Avoid exposure routes: prevent inhalation of dust/aerosols, ingestion, and skin/eye contact. Wash thoroughly after handling.
  • Handling of deuterated standards: Treat similarly to the unlabeled analog. Although deuteration does not inherently add hazard, rely on the SDS for hazard classification.
  • Incompatibilities: Strong oxidizers and strong bases/acids may degrade imide-containing compounds (general chemical knowledge). Avoid reactive metals if using strong basic conditions.
  • First-aid overview (general):
    • Inhalation: move to fresh air; seek medical attention if symptoms persist.
    • Skin/eye contact: rinse with plenty of water for at least 15 minutes; remove contaminated clothing.
    • Ingestion: rinse mouth; seek medical advice.
  • Spill response: Collect solids by gentle sweeping; for solutions, absorb with inert material. Dispose in accordance with institutional and local regulations.
  • Fire safety: Use CO2, dry chemical, or foam; combustion may produce COx and NOx (general for nitrogen-containing organics).
Solvent Selection

Solvent choice for Methsuximide-d5 should prioritize analytical compatibility and stability, since this material is primarily used as an internal standard.

  • Primary stock solvents (general practice):

    • Methanol (LC–MS grade): excellent for routine LC–MS/MS; good solubility expected for succinimide derivatives.
    • Acetonitrile (LC–MS grade): strong choice for high-organic mobile phases and precipitation workflows.
    • DMSO (anhydrous): high solvating power for concentrated stocks; dilute promptly into MeOH/ACN/water before injection to limit viscosity effects.
  • Mobile-phase compatibility (general):

    • Aqueous buffers at low ionic strength (e.g., 2–10 mM ammonium formate/acetate) with 0.1% formic or acetic acid are commonly used for positive or negative ESI, depending on method development needs.
  • Considerations for deuterated analytes:

    • Retention and ionization closely track the unlabeled parent; minor isotope effects may slightly shift retention time. Pair the labeled IS with the same chromatographic conditions as the analyte.
    • Avoid highly basic aqueous media if hydrolysis of the imide core is a concern (general for imides).
  • Comparison (general guidance):

    • Methanol vs acetonitrile: MeOH offers stronger hydrogen-bonding and can improve solubility; ACN often yields sharper peaks and lower backpressure in RP-LC.
    • DMSO: best for preparing concentrated stocks; limit final injection solvent to ≤5% DMSO to prevent peak distortion.
Storage and Reconstitution
  • Storage (from Product Data): Store at 2–8°C. Shipped on wet ice.

  • Reconstitution and handling (general guidance):

    • Bring container to room temperature in a desiccated environment before opening to prevent moisture condensation.
    • Reconstitute in LC–MS grade methanol or acetonitrile to prepare a master stock. If higher solubility is required, small amounts of DMSO can be used, then further dilute with MeOH/ACN/water prior to injection.
    • Prepare single-use aliquots to minimize freeze–thaw cycles. For multi-use vials stored at 2–8°C, limit time at ambient conditions and recap promptly.
    • Protect from light if the container is ambered; while many succinimides are relatively photostable, minimizing light exposure is prudent for analytical standards.
  • Stability: Not specified for this item; refer to CoA/Spec Sheet. Confirm solution stability under your method conditions (bench-top, autosampler, and freeze–thaw) during method validation.

  • Water content / peroxides / metal limits / UV cutoff: Not specified for this item; refer to CoA/Spec Sheet.

  • Disposal: Dispose of unused solutions and waste according to institutional chemical waste procedures. Segregate non-halogenated organic solvent waste from aqueous waste where applicable.

Structure and Identity

Methsuximide-d5 is a stable-isotope–labeled analog of the succinimide-class compound methsuximide, intended for use as an analytical internal standard and tracer in research workflows.

  • Item identity (from Product Data)

    • SKU: M345476
    • Product name: Methsuximide-d5
    • CAS: 1189980-63-9
    • PubChem CID: 46782174
    • InChIKey: Not specified for this item; refer to CoA/Spec Sheet.
    • SMILES: Not specified for this item; refer to CoA/Spec Sheet.
  • Molecular details

    • Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
    • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
    • Isotopic labeling: d5 (five deuterium atoms). The exact labeling pattern/positions are not specified for this item; consult the CoA for definitive placement.
  • Structural class (general chemistry knowledge)

    • Core scaffold: succinimide (pyrrolidine-2,5-dione) derivative (literature, describing the parent methsuximide).
    • Functional groups: cyclic imide; additional substituents as in the parent methsuximide framework (literature, parent compound).
  • 2D structure description (general)

    • Five-membered imide ring (two carbonyls at 2- and 5-positions) bearing alkyl/aryl substituents characteristic of methsuximide; five hydrogens in the parent replaced by deuterium in the d5 isotopologue (exact loci not specified for this item).
Synthetic Utility

While Methsuximide-d5 is primarily an analytical standard, it also has niche synthetic and mechanistic value in research settings.

Potential utilities (general research):

  • Isotope effect studies: incorporation of a d5 label allows probing primary/secondary kinetic isotope effects in reactions involving the labeled positions (confirm labeling pattern on CoA).
  • Tracer in multistep workflows: track mass balance and degradation pathways of imide-containing molecules by MS, distinguishing from unlabeled streams.
  • Reference material in synthesis QC: verify identity and purity of synthesized methsuximide (unlabeled) by co-injection/co-spotting with the d5 analog.

Reactivity considerations (general for succinimides):

  • Imide moiety exhibits limited nucleophilicity; under strong base, ring-opening to amic acids or dicarboxylates can occur. Protect from prolonged exposure to strong nucleophiles/bases if maintaining the intact imide is desired.
  • Deuterium retention: Labels on non-exchangeable carbons are stable to neutral and mildly acidic aqueous conditions but can scramble under harsh conditions that promote C–H activation or enolization; verify with control experiments.

Note: No item-specific synthetic transformations are indicated in the Product Data; use-cases above are generalized literature practices for deuterated small molecules.

Target Specificity

Not applicable. Methsuximide-d5 is a small-molecule isotopically labeled standard and does not have biological target specificity, epitopes, clones, or isotypes. No antigen or species reactivity data apply.

Häufig gestellte Fragen

What is the purity of this product?
This product is isotopically enriched to ≥98 atom% deuterium. Isotopic enrichment is a separate specification from chemical purity — a labelled compound has both. This product is supplied at ≥98% purity (chemical assay). Lot-specific values are stated on the Certificate of Analysis.
How should this product be stored?
Store at 2–8 °C. Refrigerated storage is required to maintain the specified shelf life.
How is this product shipped?
This product ships chilled on wet ice. Unpack on arrival and transfer it to the storage condition stated above.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is 1189980-63-9, the molecular formula is C12H8D5NO2, and the molecular weight is 208.27 g/mol. InChIKey AJXPJJZHWIXJCJ-DKFMXDSJSA-N.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.

Dürfen wir Sie über Rabattaktionen informieren?

Später erinnern

Vielen Dank! Bitte überprüfen Sie Ihren E-Mail-Posteingang, um zu bestätigen.

Hoppla! Benachrichtigungen sind deaktiviert.