SA-VA is an intracellular self-assembled PROTAC based on azide and alkyne. SA-VA is able to selectively degrade VEGFR-2 and EphB4 proteins in U87 cells. SA-VA can be converted to PROTAC in situ by click reaction with the help of endogenous copper in tumor tissues. SA-VA promotes apoptosis and blocks cells in S phase.
Spezifikationen
Storage
Store at -20°C
Verschickt in
Ice chest + Ice pads
Dieses Produkt erfordert Kühlkettenversand. Grundversand und andere Economy-Optionen sind nicht verfügbar.
Namen und Kennungen
Molekulargewicht
1044.54
Erweiterte Daten
Zertifikate (CoA, COO, BSE/TSE und Analyse-Diagramm)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Lösungsrechner
Molarity Calculator
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
Bewertungen
Kundenbewertungen
Application Protocols
No tested application protocols are provided for SA-VA in the Product Data.
General starting points (discovery screening context):
Stock solution: Prepare 10–50 mM in anhydrous DMSO; vortex and sonicate if needed. Filter (0.22 µm) to remove particulates if compatible.
Assay dosing: Typical starting concentration ranges for primary screening are 1–50 µM (final), with serial dilutions for concentration–response curves. Confirm assay compatibility with the chosen cosolvent and surfactants.
Stability check: Analyze pre- and post-assay samples by LC–MS/UPLC to confirm compound integrity and rule out adsorption or precipitation.
Note: These are general guidelines only. Develop and validate protocols according to your platform SOPs and the compound’s disclosed properties when available.
Biological Roles
Item-specific (Product Data):
No biological function, pathway association, or target information is provided for SA-VA.
General guidance for small-molecule library members:
Intended use: As a research reagent/test article for discovery assays, target identification workflows, or phenotypic screening—without any implied biological role until demonstrated in your system.
Characterization: Establish baseline properties experimentally (stability in assay buffer, plasma protein binding if relevant to your model, and potential redox/fluorescence interference).
Orthogonal confirmation: Any observed biological activity should be supported by secondary assays (biochemical vs cellular), target engagement measurements, and structure–activity relationships from follow-up analogs.
Note: No clinical or physiological role is claimed or implied for this item. For any biology-facing work, adhere strictly to institutional approvals and safety procedures.
Buffer Applications
This product is not a buffer reagent, and no acid/base characteristics or pKa are provided. Therefore, specific buffer formulations are not applicable.
General note for assay preparation:
If SA-VA is used in biological buffers, prepare a concentrated DMSO (or other suitable solvent) stock and dilute into the desired buffer to a final organic content typically ≤1–2% v/v, verifying solubility and stability.
Common screening buffers (general examples): HEPES, Tris, or phosphate at pH 7.2–7.5; selection should be based on your assay and compound stability. No item-specific buffer recommendations are available.
Green Alternatives
Context: Without structural and process details, the environmental profile is dominated by how SA-VA is handled (solvents, energy, and waste) rather than by the molecule itself. The guidance below focuses on greener solvent choices and practices.
Assay/analytical use:
Prefer aqueous buffers with minimal DMSO (≤1–2% v/v) where feasible.
Replace DMF/NMP with DMSO or ethanol/water cosolvent systems when stability and assay tolerability allow.
Synthetic/purification workflows (general):
Consider 2-MeTHF or CPME instead of THF/diethyl ether for extractions and nonpolar reactions, balancing peroxide formation risks and recyclability.
Use ethyl acetate or IPA/EtOAc mixtures over chlorinated solvents for liquid–liquid extraction and chromatography where selectivity permits.
Adopt heptane/i-PrOH or EtOAc/hexanes gradients to reduce chlorinated waste in flash chromatography.
Illustrative comparison (general; not item-specific):
THF vs 2-MeTHF: 2-MeTHF offers bio-based sourcing and better phase separation; both can form peroxides—monitor and manage accordingly.
DCM vs EtOAc: EtOAc is less toxic and has lower environmental persistence; may require method re-optimization.
Operational practices:
Implement solvent recovery, small-volume assays (miniaturization), and right-first-time characterization (LC–MS, NMR) to decrease repeats and waste generation.
Pharmaceutical Uses
Item-specific (Product Data):
For research use only.
No pharmacopeial grade or excipient role is provided.
Context and limitations:
SA-VA is supplied for laboratory research and discovery workflows and is not intended for use in humans or animals. There is no information indicating compliance with GMP, ICH, or pharmacopeial monographs (USP/EP/JP).
General considerations (if evaluating for pre-formulation research only):
Determine identity, purity, and solid-state form (if applicable) prior to any pre-formulation experiments.
Early measurements such as kinetic solubility, chemical stability across pH, and preliminary permeability can support internal research decisions, but such data must be generated in-house for this item.
Physical Properties
Item-specific (Product Data):
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
Physical state (solid/liquid), color, odor: Not specified for this item; refer to CoA/Spec Sheet.
Literature/General (context guidance only; not specific to this item):
Because the molecular identity is not provided, properties such as melting point, boiling point, density, refractive index, pKa, logP/logD, and solubility cannot be assigned.
Practical recommendations for unknown or undisclosed small molecules (general):
Initial solubility screening: test anhydrous DMSO at 10–50 mg/mL, then dilute into assay buffer with ≤1–2% DMSO final.
If aqueous work is required, evaluate co-solvent systems (e.g., DMSO/H2O, DMSO/MeOH/H2O) and include gentle warming/sonication as needed; confirm stability by LC–MS/UPLC.
Determine UV–Vis spectrum empirically prior to HPLC quantitation to set detection wavelength appropriately.
Specifications reminder:
Any numerical values (mp, bp, UV cutoff, water/peroxide/metals) are Not specified for this item; refer to CoA/Spec Sheet.
Quality and Grades
Item-specific (Product Data):
Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.
Research Use Note: For research use only.
Interpretation and guidance:
When grade/purity is unspecified, the working assumption is a research-grade small molecule intended for discovery workflows (screening, method development, or reference use). Request the CoA to verify purity (e.g., HPLC/UPLC area %), residual solvents, water content (KF), and identity confirmation (NMR, MS).
Analytical documentation: For quantitative biology/chemistry, ask for batch-specific assay, chromatograms, and spectral data. If LC–MS quantitation is planned, a certified reference material (CRM) or internal standard may be advisable.
Stabilizers/inhibitors: None are listed for this item. If stability is a concern (e.g., hydrolysis, oxidation, photolysis), confirm whether any stabilizers are present; absence/presence should be verified from the CoA/Spec Sheet.
Suitability by application:
HTS/assay: Ensure purity and counter-screen for assay interference (e.g., PAINS, redox cycling dyes) as relevant to your platform.
Analytical: Verify identity and purity thresholds consistent with your SOP (often ≥95% by HPLC for quantitative work).
Trace-level specifications (metals, UV cutoff, specific ions): Not specified for this item; refer to CoA/Spec Sheet.
Reaction and Applications
Item-specific (Product Data):
Manufacturer applications: Not provided.
General research applications for a small-molecule library member (non-clinical, discovery-focused):
High-throughput screening (HTS) and hit finding: Use as a test article in biochemical, cell-based, or biophysical assays to identify activity signals. Implement orthogonal counterscreens to manage assay interference and aggregate formation.
SAR exploration: If structural information is available under NDA or via CoA, position SA-VA within a matched molecular series to probe substituent effects; develop preliminary structure–property relationships (solubility, permeability, stability).
Probe development: Follow-up on any activity with resynthesis, purity upgrades, and analogue synthesis; confirm target engagement by orthogonal methods (e.g., CETSA, SPR, DSF) where appropriate.
Analytical benchmarking: Use as an in-house standard in LC–MS method development (retention characterization, ionization behavior) once identity is known.
Practical tips (general):
Prepare single-use, light-protected aliquots to avoid freeze–thaw and photodegradation.
Validate compound integrity pre- and post-assay via LC–MS or UPLC to exclude false positives/negatives due to decomposition.
Include detergent controls (e.g., 0.01–0.05% Tween-20) if colloidal aggregation is a concern; confirm with dilution series and dynamic light scattering as needed.
Reaction Conditions
Not applicable without structural information. No functional groups, reactivity profile, or stability data are provided for SA-VA; therefore, typical reaction conditions, catalysts, or yields cannot be recommended for this item.
General note:
If you intend to use SA-VA as a substrate or as a synthetic intermediate, obtain its full structure and characterization package first, then consult reaction-class literature specific to the relevant functional groups (e.g., amide coupling, Suzuki–Miyaura, nucleophilic substitutions). Validate conditions on a small scale and monitor by LC–MS/UPLC/NMR.
Safety and Handling
Item-specific (Product Data):
GHS Classification: Not specified for this item; refer to SDS.
Signal Word: Not specified for this item; refer to SDS.
Hazard Statements (H-codes): Not specified for this item; refer to SDS.
Pictograms: Not specified for this item; refer to SDS.
Storage Conditions: Store at −20 °C.
Shipped In: Ice chest + ice pads.
General laboratory guidance (for small organic molecules; defer to the SDS for authoritative information):
PPE: lab coat, safety glasses, and appropriate chemically resistant gloves (e.g., nitrile). Use a fume hood to avoid inhalation exposure and to prevent accumulation of vapors/aerosols.
Handling: Avoid skin/eye contact. If preparing DMSO or DMF stock solutions, prevent dermal exposure (these solvents enhance dermal absorption). Use low-retention tips for viscous solutions.
Incompatibilities: Unknown for this item. Until specifics are known, avoid strong oxidizers and strong acids/bases and segregate from reactive metals and ignition sources.
First aid (overview): In case of skin/eye contact, rinse with copious water for at least 15 minutes and remove contaminated clothing. If inhaled, move to fresh air. If ingested, rinse mouth; seek medical attention. Always follow the SDS.
Waste: Collect as organic chemical waste; label accurately based on solvent used (e.g., DMSO solution) and follow institutional disposal procedures.
Special risks: If the compound is moisture/light/air sensitive (unknown here), minimize exposure; consider amber containers and inert atmosphere as precautionary measures until stability is confirmed experimentally.
Solvent Selection
Item-specific (Product Data):
No solvent or solubility data provided for SA-VA.
General strategy for unknown/undisclosed small molecules:
Stock preparation hierarchy (typical):
DMSO (anhydrous) – high solvating power for diverse chemotypes; prepare 10–50 mM stocks.
DMF or NMP – alternatives when DMSO is insufficient (evaluate toxicity/handling implications).
Alcohols (MeOH, EtOH, i-PrOH) – useful for moderately polar compounds; often compatible up to 1–5% in aqueous assays.
Acetonitrile – miscible with water, LC-friendly; assess chemical stability.
EtOAc/THF/2-MeTHF/CPME – for nonpolar to mid-polar materials, mainly for synthetic or purification contexts.
Aqueous work: Use co-solvent strategies (≤1–2% DMSO or MeOH v/v) and surfactants only if validated to not perturb the assay.
pH and ionization: If ionizable groups are suspected, evaluate solubility at bracketing pH (e.g., citrate pH 3, phosphate pH 7, borate pH 9) to map behavior; confirm no degradation via LC–MS.
Filtration: For assay use, 0.22 µm filtration can improve reproducibility; check for sorptive losses with highly lipophilic compounds.
Note: Because identity is undisclosed, solvent choice must be verified empirically. No item-specific solubility or dielectric properties are available.
Storage and Reconstitution
Item-specific (Product Data):
Storage Conditions: Store at −20 °C.
Shipped In: Ice chest + ice pads.
General recommendations (since appearance and solvent are not specified):
Upon receipt: Keep cold. Allow container to equilibrate to room temperature before opening to minimize moisture condensation, especially if the compound is hygroscopic (unknown here).
Reconstitution: If provided as a solid, dissolve in anhydrous DMSO to prepare a concentrated stock (e.g., 10–50 mM). If provided as a solution, note the solvent and concentration on arrival and maintain at the recommended temperature.
Aliquoting: Prepare single-use aliquots in inert, amber vials or plates to avoid freeze–thaw cycles and potential photodegradation. Label with lot, concentration, and date.
Storage of solutions: Store DMSO stocks at −20 °C or −80 °C depending on your stability assessment. Avoid repeated freeze–thaw; thaw on ice and return promptly to storage.
Stability: Not specified for this item; refer to CoA/Spec Sheet. Verify by periodic LC–MS/UPLC.
Reminder: For any deviations (e.g., long-term storage at other temperatures, light sensitivity), follow the batch-specific guidance in the CoA and SDS.
Structure and Identity
Brief overview: SA-VA is listed as a small-molecule/compound library member. Structural identifiers are not provided in the Product Data.
Item-specific (Product Data):
Product Name: SA-VA (SKU: S1417385)
CAS: S1417385 (internal/catalog identifier as listed)
Molecular Formula: Not specified for this item; refer to CoA/Spec Sheet.
Molecular Weight: Not specified for this item; refer to CoA/Spec Sheet.
SMILES: Not specified for this item; refer to CoA/Spec Sheet.
InChIKey: Not specified for this item; refer to CoA/Spec Sheet.
CID: Not specified for this item; refer to CoA/Spec Sheet.
Structural features:
Not available from the provided Product Data. Without a structure, functional groups, ring systems, and stereochemical information cannot be described.
Notes for users:
If you require exact identifiers (formula, MW, structure) for dosing calculations, LC–MS method development, or cheminformatics, please request the current CoA/Spec Sheet or structure disclosure (if available under your purchasing agreement).
Synthetic Utility
Item-specific (Product Data):
No structural information or functional group data are available; synthetic reactivity and building-block roles cannot be assigned.
General possibilities for a small-molecule library member:
Reference standard: The material may serve as an analytical standard for LC–MS/UPLC method development and retention indexing, once structure is known.
Derivatization potential: If structure becomes available and contains derivatizable handles (e.g., amine, alcohol, acid), it could be adapted into probe molecules (biotinylation/fluorophore attachment) for target identification—this is hypothetical and requires structural disclosure.
Actionable advice:
Obtain structural and purity documentation (CoA/SDS, spectra) before planning any synthetic transformations.
If resynthesis or analogue preparation is intended, develop a retrosynthetic hypothesis only after structural confirmation to avoid misallocation of resources.
Target Specificity
No target, epitope, or binding specificity information is provided for SA-VA.
Item-specific (Product Data): None.
Consequently, species reactivity, binding constants, and selectivity profiles are not available. Any target engagement must be established empirically within your assay system.
Häufig gestellte Fragen
How should this product be stored?
Store at ?20 °C. Freezer storage is required to maintain the specified shelf life.
How is this product shipped?
This product ships in an insulated container with ice pads. Unpack on arrival and transfer it to the storage condition stated above.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is S1417385, the molecular formula is C50H53ClF3N11O7S, and the molecular weight is 1044.54 g/mol.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.
Wir verwenden Cookies, um die ordnungsgemäße Funktion der Website sicherzustellen und, soweit zulässig, Ihr Nutzererlebnis zu verbessern. Sie können Ihre Einstellungen jederzeit unter „Einstellungen“ verwalten. Weitere Informationen finden Sie in unserer Cookie-Richtlinie.
Dürfen wir Sie über Rabattaktionen informieren?
Später erinnern
Vielen Dank! Bitte überprüfen Sie Ihren E-Mail-Posteingang, um zu bestätigen.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.