attribute_line_ids/value_ids

Cat. No.: H1509762
Zu bestellen verfügbar
QUALITÄT & REINHEIT BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.
★
Größe
Deutschland (EU)
USA*
Preis
Menge
96T
H1509762-96T
Auf Bestellung · 8–12 Wochen
520,56€
Enter a quantity for the sizes you want to add.

Übersicht

This kit employs a sandwich enzyme-linked immunosorbent assay (ELISA) for the quantitative detection of Human Adiponectin/Acrp30 concentration in samples. The Human Adiponectin/Acrp30 capture antibody is pre-coated onto the microtiter plate. Upon addition of samples or standards, Human Adiponectin/Acrp30 present therein binds to the immobilized capture antibody, while other unbound components are removed through washing. Subsequently, a biotin-conjugated detection antibody specific for Human Adiponectin/Acrp30 is added. This antibody binds to the captured Human Adiponectin/Acrp30, forming a "sandwich" immunocomplex. Any excess, unbound material is again removed by washing. Next, an enzyme conjugate (typically Streptavidin-Horseradish Peroxidase, SA-HRP) is added. The biotin on the detection antibody and streptavidin on the enzyme conjugate exhibit high-affinity binding, thereby linking the HRP enzyme to the immunocomplex. Following another wash step to remove unbound conjugate, a colorimetric substrate (e.g., TMB) is added. If Human Adiponectin/Acrp30 is present in the sample, the HRP linked to the complex catalyzes the oxidation of the colorless substrate, yielding a blue product. The reaction is then stopped by adding a stop solution (usually an acid), which changes the color from blue to yellow. The optical density (OD) of each well is measured at 450 nm using a microplate reader. The concentration of Human Adiponectin/Acrp30 is directly proportional to the OD450 value. A standard curve is generated by assaying known concentrations of Human Adiponectin/Acrp30, and the concentration of Human Adiponectin/Acrp30 in unknown samples is interpolated from this curve based on their OD values.

Spezifikationen

Spezifikationen & Reinheit
BioReagent
Note
BioReagent
Anwendung
ELISA
Probentyp
Gewebehomogenate, Körperflüssigkeiten, Plasma, Serum, Zellkulturüberstände
Erfassungsbereich
0.78 ng/mL~50 ng/mL
Methode des Nachweises
Sandwich ELISA
Erkannte Art Objekt
Human
Spezifität
Detecting Human Adiponectin/Acrp30 in samples, with no significant cross-reactivity to other homologs.
Detection instrument
Microplate reader
Detection wavelength
450nm
Lagerung und Versand
Storage
Store at 2-8°C
Verschickt in
Wet ice
Stabilität und Lagerung
Store at 2-8℃ for 6 months.

Erweiterte Daten

Zertifikate (CoA, COO, BSE/TSE und Analyse-Diagramm)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
FAQs und Artikel
Lösungsrechner
Bewertungen

Kundenbewertungen

Benötigen Sie Hilfe bei der Auswahl der Qualität?

Unser Leitfaden zur Qualitätsauswahl behandelt Reinheit, Stabilisatorstatus und Anwendungseignung für alle Varianten in unserem Katalog.

BioReagent Qualitätsleitfaden ansehen →

Dürfen wir Sie über Rabattaktionen informieren?

Später erinnern

Vielen Dank! Bitte überprüfen Sie Ihren E-Mail-Posteingang, um zu bestätigen.

Hoppla! Benachrichtigungen sind deaktiviert.