QUALITÄT & REINHEITBioReagent?BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.Suitable for electrophoresis?Electrophoresis grade — low ionic/UV impurities for clean gel runs. Use in agarose/PAGE electrophoresis where impurities distort bands.Color change range: pH 3.0 (yellow) – pH 4.6 (blue)
Bromophenol blue is a pH indicator that changes color from yellow to blue over the pH range of 3.0–4.6. It is commonly used as an electrophoresis tracking dye to indicate the migration of small nucleic acids or proteins in gels, and is a widely used molecular biology reagent.
Procedure (for reference only):
Perform the operation according to the specific requirements of the experiment.
Precautions:
1.For your safety and health, please wear a lab coat and disposable gloves during operation.
2.This product is for research use only and must not be used for other purposes.
Spezifikationen
Spezifikationen & Reinheit
BioReagent, Suitable for electrophoresis, Color change range: pH 3.0 (yellow) – pH 4.6 (blue)
Stabilität und Lagerung
Store at RT long term (12 months).
Storage
Room temperature
Verschickt in
Normal
Note
BioReagent, Für die Elektrophorese geeignet
Product Line
Biologische Produkte
Erweiterte Daten
Zertifikate (CoA, COO, BSE/TSE und Analyse-Diagramm)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Lösungsrechner
Molarity Calculator
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
Bewertungen
Kundenbewertungen
Application Protocols
The following are general laboratory protocols using a 2% aqueous bromophenol blue stock (literature guidance). Adjust to your system and consult your SOPs.
A. DNA agarose gel loading dye (6×) preparation
Combine: 10 mL 1 M Tris-HCl pH 7.5–8.0, 6 mL 0.5 M EDTA, 30 mL glycerol, 12.5 mL of 2% bromophenol blue stock, bring to 100 mL with water. Mix until homogeneous; sterile-filter if required. Use at 1× by mixing 1 part 6× dye with 5 parts sample.
B. SDS–PAGE sample buffer tracking dye addition
Prepare or obtain 2× Laemmli buffer. Add 1 mL of 2% bromophenol blue per 100 mL buffer to achieve ~0.02%. Mix thoroughly. Add reducing agent as required by your protocol.
C. Electrophoresis run and visualization
Load samples containing dye. Run gels under standard conditions. The dye front will migrate near the ion front; stop the run when the front reaches the desired position (empirically determined for your gel % and buffer).
D. pH indication (qualitative)
Add small drops of diluted dye to acidic samples/buffers. Observe color: yellow (acidic) to blue (less acidic) across pH ~3.0–4.6.
Notes
Prevent cross-contamination; use clean tips to avoid staining.
For fluorescence imaging workflows, ensure the visible dye does not interfere with excitation/emission or quenchers used.
Biological Roles
Scope
Bromophenol blue is a synthetic sulfonephthalein dye with no known endogenous biological role. The aqueous 2% product is intended for laboratory workflows.
Laboratory relevance (literature)
Electrophoresis workflows: Functions as an inert tracking dye, co-migrating near the ion front to provide a visual marker for run progress in DNA/RNA agarose gels and protein PAGE. It does not bind specifically to biomacromolecules under standard running conditions and is typically removed during downstream processing.
pH visualization: Serves as a qualitative reporter of acidic pH shifts in biochemical buffers and column fractions (transition window approx. pH 3.0–4.6). This can be helpful in monitoring buffer exchange, desalting steps, or onset of acidic elution in ion-exchange chromatography.
Spectral/assay considerations
Absorbance in the visible region allows use as a tracer for flow paths and mixing studies in microfluidic or bioprocess lab models without interfering with UV-based nucleic acid quantification (provided measurement wavelengths and blanking are chosen appropriately).
Notes
As with any indicator dye, matrix effects (protein binding, detergents, high salt) can subtly shift apparent color and mobility. Empirical verification in your system is recommended.
No medical or clinical uses are implied; for research use only (per Product Data).
Buffer Applications
Primary uses
Electrophoresis sample loading buffers (DNA/RNA and protein): The 2% aqueous stock is convenient for preparing concentrated loading dyes.
pH indication: Qualitative monitoring of acidic pH (transition ~3.0–4.6, literature) in various aqueous buffers.
Preparing common loading dyes (example recipes; literature guidance)
6× DNA loading dye (typical):
Final composition: 10 mM Tris-HCl (pH 7.5–8.0), 6 mM EDTA, 30% glycerol (or 15% Ficoll), 0.25% bromophenol blue (w/v equivalent), optional 0.25% xylene cyanol.
Using this 2% stock: To reach 0.25% in the final 6× dye, add 12.5 mL of 2% stock per 100 mL final volume (since 2% × 12.5 mL / 100 mL = 0.25%). Adjust volumes proportionally for smaller batches.
Final composition: 125 mM Tris-HCl pH 6.8, 4% SDS, 20% glycerol, 0.02% bromophenol blue; reducing agent as required.
From 2% stock: Add 1 mL per 100 mL of buffer to obtain 0.02%.
Practical tips
Filter sterilize (0.22 µm) if sterility is required; store working dyes in amber vials to limit light exposure.
Match the indicator matrix to the run buffer (e.g., TAE vs. TBE) for consistent migration.
For precise pH visualization, calibrate color at your specific ionic strength and temperature.
Item-specific notes
Concentration basis and any preservatives in this item are Not specified for this item; refer to CoA/Spec Sheet.
Green Alternatives
Context
The product is supplied as an aqueous solution—water is a preferred solvent under green chemistry principles, minimizing flammability and VOC emissions.
Considerations and comparisons (general; literature)
Aqueous indicator vs. organic solvent solutions:
Environmental impact: Water-based formulations reduce solvent waste and worker exposure compared with alcohol- or acetone-based dye stocks.
Performance: For electrophoresis, aqueous stocks are directly compatible with common buffer systems (TAE/TBE, Tris–Glycine), reducing the need for solvent exchange.
Alternative tracking dyes:
Orange G and xylene cyanol offer different migration rates; selection can reduce reruns and energy consumption by better matching the gel percentage and fragment size distribution.
Trade-offs
Bioburden control: Aqueous solutions can be more susceptible to microbial growth over extended storage; if sterility is critical, sterile-filter on receipt and use clean technique.
Stability: Some dyes may slowly photodegrade; store away from strong light to prolong shelf life.
Practical green tips
Use concentrated stocks (e.g., 2%) to minimize packaging and shipping mass; dilute at point of use.
Scale aliquots to minimize waste; avoid repeated freeze–thaw if you choose to refrigerate.
Collect dye-containing waste separately if institutional policies require colorant control in aqueous discharge.
Pharmaceutical Uses
This product is a BioReagent-grade aqueous indicator solution intended for research use only (per Product Data). It is not offered with pharmacopeial compliance and is not intended for use as a drug substance, excipient, or in manufacturing of products for human or veterinary administration.
Context (general)
Bromophenol blue is occasionally referenced in analytical procedures as a visual indicator; however, when pharmaceutical manufacturing or QC is involved, reagents must meet relevant pharmacopeial or GMP specifications. This catalog item does not specify such compliance.
Guidance
For any application intersecting regulated environments, verify suitability and documentation with your QA team and obtain a specification sheet and SDS for the exact lot.
If an indicator is required in validated methods, ensure that grade, impurity profile, and concentration basis are defined and controlled under your quality system.
Summary
No clinical or therapeutic claims are made or implied. For research and laboratory use only, consistent with the Product Data.
Physical Properties
Item-specific data (as supplied)
Form: Aqueous solution
Concentration: 2% (label claim). Exact basis not specified for this item; refer to CoA/Spec Sheet.
Color/appearance, density, refractive index, pH of solution, UV cutoff, impurities, stabilizers: Not specified for this item; refer to CoA/Spec Sheet.
General/literature properties for bromophenol blue (indicator dye; not item specifications)
Acid–base transition range (visual): Approx. pH 3.0–4.6 (literature). Acid form appears yellow; basic/anion form appears blue to purple depending on medium.
pKa (dye acid/base equilibrium): ~4.0–4.2 (literature), medium dependent.
Spectral characteristics (typical, aqueous): λmax(acid) ~420–435 nm; λmax(base) ~585–600 nm (literature). Useful for monitoring fronts in electrophoresis.
Solubility: Readily soluble in water when supplied as solution or sodium salt; limited solubility as free acid (literature). Solubility of this specific item’s solution is intrinsic (already in water).
Practical notes
Working concentrations in gels/buffers typically range from ~0.005–0.25% w/v (literature) depending on application (e.g., 1× loading buffers). The 2% stock facilitates convenient dilution to working strengths.
If precise absorbance or extinction coefficients are required for quantitation, determine empirically under your buffer and pH conditions, or consult literature for the specific dye form.
Quality and Grades
Item-specific facts
Grade/Purity: BioReagent (per Product Data). No additional impurity profile or stabilizer details are provided for this item; refer to CoA/Spec Sheet.
What BioReagent grade implies (general guidance)
Intended for laboratory and life-science workflows such as electrophoresis, sample loading dyes, and visual pH indication. Emphasis is on functional performance (color transition, tracking behavior) rather than pharmaceutical or GMP compliance.
Typical expectations include consistent dye performance across lots, low particulate content, and a well-behaved color transition in aqueous buffers used in proteomics/genomics labs.
Practical quality considerations for this product class
UV–Vis performance: For reproducible tracking, many users verify λmax and absorbance at working dilutions to ensure lot-to-lot consistency (literature practice). If critical, confirm with a quick spectrum in your buffer.
Particulates/clarity: Solutions should appear homogeneous; filter through 0.22–0.45 µm if your downstream application is sensitive to particulates. If sterile applications are required, sterile-filter into clean vials.
Preservatives/salt form: If your protocol is sensitive to antimicrobial agents or specific counterions (e.g., sodium), consult the CoA/SDS to confirm absence/presence.
Documentation
For regulated or highly standardized workflows (e.g., validated QC methods), retain the lot CoA and SDS. Any attributes not listed in the Product Data (e.g., dye assay, exact concentration basis, pH) are Not specified for this item; refer to CoA/Spec Sheet.
Reaction and Applications
This product is primarily a visualization/indicator reagent rather than a synthetic reactant. Key laboratory applications include:
Electrophoresis tracking (literature)
DNA/RNA agarose gels: Added to sample loading buffers to visualize the sample front during electrophoresis. Bromophenol blue typically migrates with DNA fragments of ~300–500 bp in standard 1% agarose in TAE/TBE (migration depends on gel %, buffer, and voltage), providing an approximate position reference.
Protein PAGE (SDS–PAGE/native): Included in Laemmli sample buffers; the dye front indicates run progress and facilitates uniform lane loading.
pH indication and titrations (literature)
Operates in the acidic range (approx. pH 3.0–4.6). Useful for quick checks of buffer acidification, column fractions, or qualitative titrations where a sharp color change is advantageous.
Method development and QA/QC
Tracking solution for membrane transfer (Western blot) to visualize transfer efficiency and lane alignment on membranes.
Column chromatography visual aid: Small additions to aqueous mobile phases provide visual cues for fraction collection start/stop (ensure no analytical interference).
Practical tips
Prepare working solutions fresh at 0.005–0.25% depending on application; the supplied 2% stock supports convenient serial dilutions.
For nucleic acids, ensure the dye does not overlap with detection wavelengths or intercalating dyes used for imaging.
Validate migration under your exact gel/buffer conditions, as ionic strength and gel percentage influence dye mobility.
Reaction Conditions
This product is not typically used to drive or catalyze chemical reactions; it functions as a visual indicator/tracking dye. As such, classical “reaction conditions” (temperature, catalysts, stoichiometry) are not directly applicable.
Practical usage conditions (literature guidance)
Electrophoresis: Incorporated into sample loading buffers and running in standard gel conditions (e.g., 1× TAE/TBE for agarose; Tris–Glycine or MES/MOPS for PAGE) at ambient temperature. Voltage, gel percentage, and buffer define dye migration.
Spectrophotometry: For absorbance checks, measure at the appropriate λmax for the dye’s protonation state; ensure pH control. Room temperature is typical; spectra are modestly temperature dependent.
pH indication: Use within the transition range (~3.0–4.6) for sharp visual endpoints.
Incompatibilities and stability
Strong oxidants may bleach the dye. Very high or very low pH will change color and can eventually degrade the chromophore upon prolonged exposure.
Avoid organic solvent fractions that precipitate or extract the dye away from aqueous phase if consistent tracking is needed.
Summary
Treat as a ready-to-use aqueous visual aid. Where method-critical, confirm performance empirically under your exact buffer, temperature, and ionic strength.
Safety and Handling
Item-specific hazard information
GHS classification, signal word, pictograms, H-statements: Not specified for this item; refer to the SDS for authoritative safety data.
Storage: Room temperature (per Product Data). Protect from contamination; keep container tightly closed.
General safety guidance (good laboratory practice; not a substitute for the SDS)
PPE: Lab coat, safety glasses, and appropriate chemical-resistant gloves. Avoid skin/eye contact; dyes can strongly stain.
Handling: Use in well-ventilated areas. Prevent aerosol formation and avoid ingestion. Clean spills promptly—dyes can permanently stain benches and plastics.
Incompatibilities: Strong oxidizers may degrade organic dyes; strong acids/bases can shift color/ionization and may affect analytical outcomes. Avoid mixing with bleach/chlorinated oxidants to prevent formation of halogenated organics.
First aid (overview):
Skin: Wash with soap and water; remove contaminated clothing.
Eyes: Rinse cautiously with water for several minutes; remove contact lenses if present and easy to do.
Ingestion/Inhalation: Seek medical advice; move to fresh air if inhaled dust/aerosol.
Environmental: Prevent uncontrolled release; dyes can be visually detectable at very low concentrations.
Special notes for aqueous indicator solutions
Avoid freezing/thawing cycles that can cause precipitation or concentration shifts from water loss. If crystals/precipitate form after low-temperature exposure, gently warm and mix to re-dissolve.
Always refer to the lot-specific SDS/CoA for definitive safety classifications and any preservatives present.
Solvent Selection
Applicability to this item
The supplied material is an aqueous solution; no alternative solvent selection is typically required for routine use.
General solvent behavior (literature; for the dye component)
Primary solvent: Water. The dye’s color is pH-dependent in aqueous media; ionic strength and cosolvents can subtly shift spectra.
Miscibility: Fully miscible with common biological buffers (e.g., TAE/TBE, Tris–Glycine, phosphate buffers, MES) and with polyol-containing loading buffers (e.g., glycerol, sucrose). Compatible with low percentages of organic modifiers (methanol, ethanol) commonly used in gel preparation and transfer buffers.
Polarity class: Highly polar aqueous systems; the dye remains in solution as an anion/zwiterion above its pKa.
When to adjust solvent or medium
Electrophoresis tracking: Use in the same buffer system as your gel/run buffer to ensure accurate front migration.
Spectroscopy: For analytical absorbance work, define pH and ionic strength rigorously; record spectra in the exact matrix used for standards and samples.
Protein work: Avoid high concentrations of strong denaturants (e.g., >6 M guanidine) if spectral readout is needed; these may alter baseline and apparent λmax. For simple tracking, compatibility is usually adequate.
Alternatives/adjuncts
Other tracking dyes (literature): Xylene cyanol (slower migration), Orange G (faster front), bromocresol green (different pH range). Choice depends on desired migration speed and contrast.
Storage and Reconstitution
Item-specific storage
Storage conditions: Room temperature (per Product Data). Shipments: Normal conditions.
Reconstitution: Not required; supplied as a ready-to-use aqueous 2% solution. Any further dilution to working concentrations should be performed with clean water or the target buffer.
Handling and aliquoting
Upon receipt, inspect for homogeneity. If any precipitate is observed (e.g., after cold exposure), gently warm to ambient and invert to re-dissolve.
Aliquot into amber or opaque microtubes/bottles to minimize light exposure and contamination. Label with preparation/dilution dates.
Stability considerations
Exact shelf life and preservative content: Not specified for this item; refer to CoA/Spec Sheet.
Avoid microbial contamination: If long-term storage is anticipated or sterility is required, sterile-filter (0.22 µm) into sterile vials and handle aseptically.
Do not freeze unless validated; freeze–thaw can concentrate solutes via ice exclusion and potentially precipitate components.
Working solution preparation (examples)
DNA loading dye: Dilute the 2% stock into your 6× master mix to achieve the desired final percentage (e.g., 0.25% in 6×). Store working solutions at room temperature or 2–8°C protected from light, according to lab practice.
Documentation
For parameters not provided in the Product Data (e.g., pH, exact concentration basis, stabilizers), consult the lot-specific CoA/Spec Sheet and SDS. For research use only (per Product Data).
Structure and Identity
Item-specific facts (from Product Data)
Product: Bromophenol Blue Aqueous Solution (2%)
SKU: B1528879
Grade: BioReagent
Storage: Room temperature; shipped under normal conditions
CAS, InChIKey, SMILES, Molecular Formula, Molecular Weight: Not specified for this item; refer to CoA/Spec Sheet.
General/literature description (for the dye component “bromophenol blue”)
Chemical class: Sulfonephthalein pH indicator dye; a tetrabrominated phenolsulfonephthalein derivative.
Structural features (2D description): A triphenylmethane-like core with a central sp3 carbon linking two phenolic rings and a benzenesulfonate-derived ring (sulfone bridge). Multiple phenolic groups and four bromine substituents confer high color contrast between protonation states. Exists as zwitterionic/anion forms depending on pH.
Indicator behavior (literature): Exhibits a yellow (acid) ⇄ blue (base) transition in the low-acidic pH range; commonly used as a tracking/visual indicator in biochemical electrophoresis and as a pH indicator in the ~3–5 pH window.
Notes
The supplied material is an aqueous solution of the dye at 2% as labeled; exact basis (w/v vs. w/w) and counterion, if any, are not specified for this catalog item and should be confirmed from the CoA/Spec Sheet.
When citing exact identifiers (CAS, formula, MW), use the documentation associated with this lot of the aqueous solution or the SDS.
Synthetic Utility
Not a typical synthetic building block. Bromophenol blue aqueous solution is used as an indicator/tracking aid rather than as a reagent participating in bond-forming reactions.
General considerations (literature)
Acid–base indicator: Can be used to visually monitor the endpoint of acidic titrations within its transition range (~pH 3.0–4.6). This is an observational role, not a stoichiometric transformation.
Tracer in unit operations: In flow experiments or method development (chromatography, microfluidics), the dye can help visualize residence times, dead volumes, or dispersion.
If a colored reagent is needed synthetically
For monitoring pH during workups or extractions (e.g., confirming acidic aqueous washes), small aliquots of indicator solution can provide rapid checks. Be aware that surfactants/solvents may affect color and partitioning.
Notes
Because this is an aqueous 2% solution, introducing it into moisture-sensitive synthetic steps is generally inappropriate. For anhydrous contexts, indicators with compatible solvents or pH meters are preferred.
Any use in synthesis should consider potential contamination of analytical endpoints due to the intense color and potential adsorption on solids.
Target Specificity
Not applicable. This product is a small-molecule indicator dye solution and is not an antibody, probe, or affinity reagent. No antigen/epitope specificity, clone information, species reactivity, or isotype applies.
Häufig gestellte Fragen
How should this product be stored?
Store at room temperature.
Benötigen Sie Hilfe bei der Auswahl der Qualität?
Unser Leitfaden zur Qualitätsauswahl behandelt Reinheit, Stabilisatorstatus und Anwendungseignung für alle Varianten in unserem Katalog.
Wir verwenden Cookies, um die ordnungsgemäße Funktion der Website sicherzustellen und, soweit zulässig, Ihr Nutzererlebnis zu verbessern. Sie können Ihre Einstellungen jederzeit unter „Einstellungen“ verwalten. Weitere Informationen finden Sie in unserer Cookie-Richtlinie.
Dürfen wir Sie über Rabattaktionen informieren?
Später erinnern
Vielen Dank! Bitte überprüfen Sie Ihren E-Mail-Posteingang, um zu bestätigen.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.