QUALITÄT & REINHEITMoligand™?Moligand™ — Aladdin's line of ligands and bioactive small molecules. Use for receptor, pathway, and binding studies needing defined small-molecule tools.
Zertifikate (CoA, COO, BSE/TSE und Analyse-Diagramm)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Lösungsrechner
Molarity Calculator
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
Bewertungen
Kundenbewertungen
Application Protocols
The following general protocols are suitable for many small-molecule screening compounds. They are provided as practical guidance and are not item-specific specifications.
Stock preparation
Dissolve the compound in anhydrous DMSO to 10–50 mM. If dissolution is slow, sonicate briefly or warm gently (<40°C). Record the exact concentration by weight-in/volume or by UV if extinction coefficient is known.
Serial dilution for assays
Prepare an 11-point 3-fold serial dilution in DMSO (or buffer-compatible mix). Transfer to assay plates to achieve final 0.1–0.5% DMSO v/v. Include vehicle and positive controls on every plate.
Aggregation/artifact control
Include 0.01–0.05% Tween-20 in assay buffer if colloidal aggregation is suspected. Run orthogonal readouts to rule out fluorescence interference or redox cycling.
Plate handling
Use polypropylene plates; seal with solvent-resistant films to limit evaporation. Equilibrate plates to room temperature before reading to minimize edge effects.
Analytical check
Verify solution integrity by LC–MS or HPLC at time 0 and end-of-assay to confirm stability and concentration.
Note: Adjust concentrations and conditions to your assay’s dynamic range and biology. No biological activity or recommended dose is specified for this item.
Biological Roles
Item-specific biological role, target class, and mechanism of action for MRS2603 are not provided in this listing.
General considerations for small-molecule research tools (literature/general)
Small molecules are frequently employed to probe biochemical pathways, transiently modulate enzyme or receptor function, or serve as chemical probes in target validation. However, without structure and characterization data, no biological role should be inferred.
Any putative role or activity must be established experimentally with orthogonal assays, concentration–response characterization, and appropriate counter-screens to exclude interference (aggregation, redox cycling, fluorescence/absorbance overlap).
Compliance note
This product is labeled For research use only. It is not intended for diagnostic, therapeutic, or in vivo clinical use. No biological claims are made or implied for this specific item.
Buffer Applications
This product is a small-molecule research compound and is not a buffering agent. No buffer capacity, pKa profile, or recipe is provided for MRS2603.
Practical note (general)
When deploying the compound in biochemical assays, prepare it as a concentrated DMSO stock and dilute into your chosen assay buffer (e.g., HEPES, Tris, PBS) to a final DMSO content typically ≤0.1–0.5% v/v, verifying solubility and absence of precipitation. Optimize ionic strength and pH based on the biology of the assay, not the compound.
Green Alternatives
While MRS2603 is a discrete small molecule (not a solvent or reagent used in bulk), greener choices can be applied to its handling and analytics (general guidance):
Prefer aqueous buffers with minimal DMSO (≤0.1–0.5% v/v in assays) when solubility permits. This reduces VOC exposure and waste.
If organic co-solvent is required, consider bio-based or lower-toxicity options such as ethanol or 2-propanol over DMF/NMP, provided solubility and assay compatibility are acceptable.
For reaction quench/extraction steps in assay workups, evaluate ethyl acetate or CPME instead of chlorinated solvents, balancing analyte recovery and matrix effects (analytical validation required).
Implement microscale screening and miniaturized HTS formats (e.g., 384-/1536-well) to reduce material and solvent consumption.
Use closed-well plate sealing to limit evaporation and VOC emissions; adopt solvent recycling where feasible for HPLC/UPLC (e.g., isocratic aqueous-rich methods).
Note: These are general sustainability practices. No alteration of the item’s composition or specifications is implied.
Pharmaceutical Uses
No pharmacopeial status, excipient role, or clinical formulation use is provided for MRS2603. This item is supplied strictly for research use only.
General context (literature/general)
In preclinical research, small molecules may be evaluated for drug-likeness and ADME properties; however, such evaluations are target- and structure-dependent and are not provided here.
If formulation screening is part of your research, standard nonclinical vehicles (e.g., aqueous buffers with minimal DMSO/PEG, or suspensions with polysorbates) can be investigated, subject to local IACUC/ethics and institutional safety policies. These considerations are outside the scope of this catalog listing and are provided only as general background.
No therapeutic or clinical claims are made for this product.
Physical Properties
Item-specific properties (as supplied)
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
Melting point (MP): Not specified for this item; refer to CoA/Spec Sheet.
Boiling point (BP): Not specified for this item; refer to CoA/Spec Sheet.
Density: Not specified for this item; refer to CoA/Spec Sheet.
Refractive index: Not specified for this item; refer to CoA/Spec Sheet.
Solubility: Not specified for this item; refer to CoA/Spec Sheet.
logP/logD, pKa: Not specified for this item; refer to CoA/Spec Sheet.
General guidance for small-molecule library members (literature/general)
Many discovery compounds are handled as DMSO stock solutions (e.g., 10–50 mM), with aqueous assay buffers containing 0.1–1% DMSO v/v. Actual solubility and stability can vary widely with scaffold and substituents.
If no solubility data are available, a tiered solubility screen (DMSO → DMF/MeOH → aqueous buffer with co-solvent and surfactant such as 0.01–0.05% Tween-20) can be informative.
Assess solution stability by LC–MS or HPLC over time at intended storage and assay conditions (light sensitivity, hydrolysis, redox lability, and adsorption to plastics are common considerations).
Note: Do not treat the general statements above as specifications for this item. Rely on the CoA/SDS for batch-specific physical data.
Quality and Grades
Item specifics
Grade/Purity: Moligand™ (as listed). No numerical purity, stabilizers, or additional specs are provided in this listing.
What is specified for this item: Grade designation and storage at room temperature. All other analytical limits are not specified; refer to the CoA/Spec Sheet.
About Moligand™ grade (general explanation)
Moligand™ denotes Aladdin’s line of small-molecule research ligands/tool compounds intended for discovery screening and mechanism studies. While exact QC elements can vary by compound and batch, library-grade offerings typically prioritize:
Identity confirmation (e.g., NMR/LC–MS) to verify structural assignment.
Chromatographic purity suitable for screening workflows.
Form factor compatible with plate-based operations (e.g., dry solid or concentrate for DMSO stocks).
Implications for use (general)
For biochemical or cell-based assays, users commonly prepare 10–50 mM DMSO stocks and perform serial dilutions into assay buffers. When low UV background is critical (e.g., HPLC detection), verify UV cutoff and impurity profile on the CoA.
If you require enhanced specifications (trace metals, water content, residual solvents, salt form confirmation, polymorph), contact us for custom QC or a lot-reserved CoA.
Documentation
Because item-specific specs (purity %, salt form, water/ppm, residual solvents) are not listed here, please consult the current CoA/SDS shipped with the lot for authoritative details.
Reaction and Applications
Item-specific functional/biological applications are not provided for MRS2603. The following reflects typical uses of Moligand-class small molecules in discovery research (general guidance).
Biochemical assays: Evaluate target modulation via enzyme activity or binding assays (e.g., fluorescence polarization, SPR, ITC). Establish concentration–response curves (8–12 points) with appropriate positive/negative controls.
Cell-based assays: Test phenotypic outcomes (reporter gene, viability, signaling readouts) with careful control of final DMSO (≤0.1–0.5% v/v typically).
Orthogonal confirmation: Use at least two assay modalities to deconvolute artifacts (aggregation, redox cycling, fluorescence interference). Include detergent controls and counter-screens.
Analytical characterization: Confirm assay medium integrity by LC–MS before/after incubation to detect instability (hydrolysis, oxidation). Monitor for adsorption losses in low-binding plastics.
Reference standards: Once activity is established, prepare calibrators for LC–MS bioanalytical methods or binding assay standard curves.
Important
No target specificity, mechanism, or potency is claimed for this item in the present listing. Any application should be validated empirically under your lab’s conditions. Consult the product’s CoA/SDS for material-specific constraints.
Reaction Conditions
Not applicable to this listing. MRS2603 is provided as a research compound for screening and assays, not as a reagent intended for use in synthetic reactions. No catalytic or stoichiometric reaction conditions are specified.
General note (literature/general)
If you are studying stability or metabolism, you may subject the compound to conditions such as oxidative, hydrolytic, or photolytic stress for analytical purposes (ICH-style forced degradation). Any such studies should be designed based on your analytical goals and confirmed by LC–MS/HRMS and NMR.
Refer to the CoA/SDS for any item-specific constraints before exposing the material to harsh conditions.
Safety and Handling
Item-specific hazard information
GHS classification, signal word, pictograms, H-statements: Not specified for this item; refer to SDS for authoritative classification.
General laboratory precautions (literature/general)
Handle as a research-use chemical of unknown comprehensive hazard profile. Use standard PPE: lab coat, safety glasses, and appropriate chemically resistant gloves.
Work in a fume hood to avoid inhalation of dusts, aerosols, or solvent vapors when preparing stock solutions.
Avoid contact with skin and eyes. Prevent ingestion and inhalation. Wash thoroughly after handling.
For solution handling in DMSO/DMF/MeOH, note these solvents can enhance dermal absorption of solutes; minimize skin contact.
Storage incompatibilities and precautions (general)
Until specific data are available, keep away from strong oxidizers/reductants and strong acids/bases. Protect from excessive heat, moisture, and prolonged light exposure.
First-aid overview (general)
Skin/eye contact: Rinse with water for several minutes; remove contaminated clothing; seek medical attention if irritation persists.
Inhalation: Move to fresh air; seek medical attention if symptoms occur.
Ingestion: Rinse mouth; do not induce vomiting; seek medical attention.
Disposal
Dispose of residues and solutions as organic laboratory waste per institutional and local regulations.
Always consult the product’s SDS for definitive, batch-specific safety information.
Solvent Selection
Item-specific solubility data are not provided for MRS2603. The guidance below reflects common practices for handling discovery compounds in screening campaigns.
Primary stock solvent (general): DMSO is typically first-choice due to broad solvating power and assay compatibility up to ~0.1–1% v/v.
Secondary options: DMF or NMP (higher solvency, but greater toxicity/absorption risk); MeOH or EtOH (volatile, lower solvency for highly lipophilic scaffolds). Cosolvent mixtures with buffer are often used for aqueous delivery.
Aqueous delivery: Introduce compound into buffer by reverse addition (add DMSO stock to vigorously mixed buffer) to limit precipitation. Consider 0.01–0.05% nonionic surfactant (Tween-20 or Pluronic F-68) if nonspecific adsorption/aggregation is suspected.
Material compatibility: Use polypropylene plates/tubes; avoid polystyrene for sticky hydrophobes. Glass vials can mitigate adsorption for analytical samples.
Mini comparison (general)
DMSO: excellent solvency, high boiling point; hygroscopic.
DMF: very strong solvent; more stringent handling due to toxicity.
MeOH/EtOH: greener profile; limited for hydrophobes; volatility impacts concentration control.
Practical tip
If solubility is unknown, perform a quick nephelometric or visual solubility check across a solvent panel and validate by LC–MS. Record the maximal clear concentration achievable at room temperature.
Storage and Reconstitution
Item-specific storage
Storage Conditions (as listed): Room temperature.
Shipped in: Not specified for this item; refer to CoA/Spec Sheet.
Appearance/Form: Not specified for this item; refer to CoA/Spec Sheet.
General best practices (literature/general)
Store the solid in a tightly sealed, inert container with desiccant, protected from excessive light. Minimize headspace to reduce oxidative/hydrolytic exposure.
For working solutions, prepare concentrated DMSO stocks (e.g., 10–50 mM), filter if appropriate (0.22 µm PTFE for organic stocks), and make single-use aliquots to avoid repeated freeze–thaw.
Although the item is stable at room temperature per listing, DMSO solutions are commonly kept at −20°C to −80°C for longer-term stability; thaw at room temperature and vortex to ensure homogeneity before use. Verify stability by LC–MS/HPLC at intervals.
Clearly label aliquots with lot number, concentration, solvent, and preparation date. Track cumulative time at room temperature for solution stocks.
Reconstitution note
If solubility in DMSO is uncertain, start with small volumes, use gentle warming/sonication, and avoid aqueous dilution until a clear stock is obtained. Document final solvent composition for reproducibility.
Always defer to the CoA/SDS for lot-specific handling and storage guidance.
Structure and Identity
A Moligand-series small molecule screening compound supplied for discovery research.
Product name (trivial): MRS2603 (as listed)
CAS: 860623-35-4 (item-specific)
PubChem CID: 135545444 (item-specific)
InChIKey: 295582 (item-specific, provided as-is)
SMILES: Not specified for this item; refer to CoA/Spec Sheet.
Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
Structural features
Item-specific structural details: Not disclosed in this listing; consult the CoA/SDS for any available structure or provide SMILES/InChI on request.
2D structure description (item): Not available from the current product data.
Context and general notes (literature/general)
Compounds designated with MRS-#### are often used in chemical biology as research ligands or tool compounds; however, the exact scaffold, functional groups, and stereochemistry of MRS2603 are not provided here and should not be inferred without source documentation.
Documentation
For definitive structural identity, please request the latest Certificate of Analysis (CoA) and SDS, which will reflect the specific batch supplied.
Synthetic Utility
MRS2603 is offered as a finished small molecule for discovery research; the structure and functional groups are not disclosed in this listing. Consequently, no specific synthetic transformations or building-block applications can be recommended.
General considerations (literature/general)
If the structure is available to you (e.g., via CoA or internal documentation) and derivatization is desired (SAR exploration, tagging), standard approaches include: protective group strategies, late-stage functionalization, or installation of affinity/reporting handles. The feasibility depends entirely on the underlying scaffold and functional group tolerance.
The compound can serve as a reference standard for analytical method development (HPLC/UPLC, LC–MS) if purity and identity are confirmed for your lot.
For synthetic planning or custom analog requests, please contact us with the structural information to assess feasibility.
Target Specificity
No target, epitope, or binding specificity is provided for MRS2603 in this listing. As a small-molecule product (not an antibody or biologic), fields such as clone, isotype, or species reactivity are not applicable.
If you establish target engagement experimentally (e.g., via SPR/ITC, CETSA, NanoBRET), document those data within your project records; they are not part of the supplied product information.
Häufig gestellte Fragen
What is Moligand??
Moligand? is one of Aladdin Scientific's premium product lines, formulated for high-purity applications across multiple workflows. Compared to standard grades in the same workflow, Moligand? products typically offer tighter specifications, more rigorous QC, and stronger lot-to-lot consistency.
How should this product be stored?
Store at room temperature.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is 860623-35-4. InChIKey QFNNQKZCKPHORP-JXAWBTAJSA-N.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.
Benötigen Sie Hilfe bei der Auswahl der Qualität?
Unser Leitfaden zur Qualitätsauswahl behandelt Reinheit, Stabilisatorstatus und Anwendungseignung für alle Varianten in unserem Katalog.
Wir verwenden Cookies, um die ordnungsgemäße Funktion der Website sicherzustellen und, soweit zulässig, Ihr Nutzererlebnis zu verbessern. Sie können Ihre Einstellungen jederzeit unter „Einstellungen“ verwalten. Weitere Informationen finden Sie in unserer Cookie-Richtlinie.
Dürfen wir Sie über Rabattaktionen informieren?
Später erinnern
Vielen Dank! Bitte überprüfen Sie Ihren E-Mail-Posteingang, um zu bestätigen.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.