Determine the necessary mass, volume, or concentration for preparing a solution.
para flujos de trabajo cromatográficos y analíticos sensibles que requieren una interferencia mínima de la línea base.
Protected from light,Store at -20°C Envío Ice chest + Ice pads. Consulte el COA específico del lote para conocer las especificaciones exactas.
SDS, COA, ficha técnica y hoja de especificaciones disponibles para descargar. COA específico del lote accesible mediante búsqueda por número de lote.
Citado en 0 publicaciones revisadas por pares sobre cromatografía, síntesis orgánica y reacciones de acoplamiento cruzado.
This product should be aliquoted properly to avoid repeated freeze-thaws.For trace amounts of liquid, centrifuge briefly before each use to collect the liquid at the bottom of the tube.Fluorescence intensity decays. Avoid light to minimize the quenching of fluorescence.Coverslips and slides are required but not supplied. They can be ordered from .Phalloidin is toxic (LD50: 2mg/kg body weight). Less than 0.2mg of phalloidin is contained in 1ml of Actin-Tracker Red. Please take effective protections when using it.This product is for R&D only. Not for drug, household, or other uses.For your safety and health, please wear a lab coat and disposable gloves during the operation.
Instructions for Use:
1.Fluorescent staining of fixed cells or tissue sectionsa.Wash the cells or tissue sections twice with PBS.b.Fix the cells or tissue sections at room temperature for about 10 minutes with 's Immunol Staining Fix Solution or 3.7% formaldehyde solution prepared with PBS. Note: Fix solutions containing methanol should not be used, because methanol can destroy actin proteins. c.Wash samples 2-4 times with 's Immunol Staining Wash Buffer or PBS containing 0.1% Triton X-100 for about 5 minutes each time.d.Dilute the Actin-Tracker Red-555 1:40-1:200 with 's Immunol Fluorescence Staining Secondary Antibody Dilution Buffer or PBS containing 1-5% BSA and 0.1% Triton X-100 (e.g., dilute 5μl or 25μl of Actin-Tracker Red-555 in 1ml of dilution buffer), to obtain the Actin-Tracker Red-555 working solution. Note: The dilution ratio can be adjusted based on the staining result.e.Add 200μl of Actin-Tracker Red-555 working solution to each slide and incubate at room temperature for 20-60 minutes in the dark. To prevent evaporation, it is better to place the slide in a Staining Box for Microscope Slides (, FSR958).f.Wash the slides 2-4 times with 's Immunol Staining Wash Buffer or PBS containing 0.1% Triton X-100 for about 5 minutes each time.g.Examine the stained samples directly by fluorescence microscopy. For long-term storage, the slide can be mounted after air-dry and stored at 4℃ in the dark for up to 6 months.2.Fluorescent staining of live cells:Phalloidin is usually not cell-permeable and is therefore rarely used for live cell staining. However, it has been reported that live cells can be labeled by phalloidin which possibly enters live cells by phagocytosis. In general, a larger amount of fluorescence-conjugated phalloidin is needed for staining live cells.
Documento completo sobre peligros, manipulación, almacenamiento y cumplimiento normativo.
<<<<<<< HEAD Descargar SDS → ======= Descargar SDS → >>>>>>> release248-p3Datos de calidad específicos del lote. Introduzca su número de lote para obtener el COA exacto.
Buscar COA →Resumen de referencia rápida de las especificaciones y aplicaciones del producto.
Ver ficha técnica →Atributos de calidad completos y criterios de aceptación para esta calidad.
Ver hoja de especificaciones →