Routine Glycerol Mounting Medium - BioReagent,for microscopy,Suitable for Immunofluorescence(IF),for fluorescence analysis

Cat. No.: C1508971
Disponible para pedir
GRADE & PURITY BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. for Fluorescence analysis ? Fluorescence-analysis grade — very low fluorescent impurities for clean spectra. Use in fluorescence assays where background interferes. for Microscopy ? Microscopy grade — reagents/stains suited to sample prep and imaging. Use in microscopy where clarity and low background are needed. Suitable for Immunofluorescence(IF) ? IF grade — validated for immunofluorescence with low background staining. Use to localize targets in cells/tissue by fluorescence microscopy.
Storage
Room temperature
Shipped In
Normal
Application
Cell Staining‌, IF/ICC
 ·  off list, applied to all prices below.
Size
Estado
Price
Qty
50ml
C1508971-50ml
1-2 wks(?)
Item is derived from our semi-finished stock and is processed in 1-2 weeks.
69,90US$
Enter a quantity for the sizes you want to add.
🧪

Why this grade

BioReagent,for microscopy,Suitable for Immunofluorescence(IF),for fluorescence analysis BioReagent,for Fluorescence analysis,for Microscopy,Suitable for Immunofluorescence(IF) for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Room temperature Ships Normal Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

Descripción general

Product Introduction

Routine Glycerol Mounting Medium is a general-purpose mounting agent that can also be used to mitigate fluorescence quenching. It is mainly composed of glycerol. Its performance in reducing fluorescence quenching is inferior to that of Antifade Mounting Medium. Based on the dosage of 50–100 μl per sample, 5 ml of the medium can be used for mounting at least 50 samples. This reagent is intended for research use only and not for clinical diagnosis or other purposes.

Materials to Be Prepared by Users

Glass slides, coverslips, fluorescence microscope

Operating Procedures (For Reference Only)

1. Adherent cell samples

① After staining, aspirate the staining solution.

② Place 1 drop of Routine Glycerol Mounting Medium onto the glass slide, then cover it with the coverslip with adherent cells attached, ensuring the cells come into contact with the mounting medium and minimizing air bubbles as much as possible.

③ Observe under a microscope.

2. Tissue sections

① After staining, aspirate the staining solution.

② Place 1 drop of Routine Glycerol Mounting Medium onto the tissue section, then cover it with a coverslip, ensuring the section is in contact with the mounting medium and avoiding air bubbles as much as possible.

③ Observe the tissue section under a microscope.

3. Other samples

For other samples, follow the procedures for cell samples or tissue sections.

Precautions

1. All fluorescent substances are prone to quenching; stained samples should be stored away from light.

2. Although Routine Glycerol Mounting Medium can reduce quenching, samples mounted with it should still be protected from light as much as possible.

3. For your safety and health, wear a lab coat and disposable gloves during operation.

4. Use the reagent as soon as possible after opening to avoid compromising subsequent experimental results.

Specifications

Especificaciones y pureza
BioReagent, for microscopy, Suitable for Immunofluorescence(IF), for fluorescence analysis
Estabilidad y almacenamiento
Store at room temperature long term (12 months).
Condiciones de almacenamiento de almacenamiento
Room temperature
Enviado en
Normal
Grado
BioReagent, for Fluorescence analysis, for Microscopy, Suitable for Immunofluorescence(IF)

Documentation

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Certificados (CoA, COO, BSE/TSE y tabla de análisis)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

1 results found

Lot NumberCertificate TypeFechaArticulo
ZJ26F0232104Certificate of AnalysisFeb 09, 2026 C1508971
Preguntas frecuentes y artículos
Calculadoras de soluciones
Reseñas

Reseñas de cliente

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.