GRADE & PURITYValidated?Validated grade — performance confirmed in defined applications before release. Use when you want documented assurance the reagent works as stated.ExactAb™?ExactAb™ — Aladdin's antibody line emphasizing precision and validated quality. Use for reliable, specificity-validated antibody applications.5 μL/test
ICAM proteins are ligands for the leukocyte adhesion protein LFA-1 (integrin alpha-L/beta-2). During leukocyte trans-endothelial migration, ICAM1 engagement promotes the assembly of endothelial apical cups through ARHGEF26/SGEF and RHOG activation. In cas
Host species
Mouse
Specificity
ICAM1/CD54
Immunogen
Human infant thymocytes and Sezary cells
Positive Control
Flow Cytometry: human peripheral blood monocytes
Conjugation
AF594
Excitation (nm)
Yellow-Green Laser(594nm)
Emission(nm)
618nm
Ex/Em(nm)
Ex:590nm;Em:618nm
Grade
ExactAb™, Validated
Concentration
5 μL/test
Storage and Shipping
Storage
Store at 2-8°C,Protected from light,Do not freeze
Shipped In
Wet ice
Stability And Storage
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Images
ICAM1/CD54 Mouse mAb (AF594) (Ab306572) - Flow Cytometry
Flow cytometry analysis of ICAM1/CD54 expression by human peripheral blood cells (right panel) compared to an isotype control (left panel). Cells were preincubated with Human Fc Receptor Blocking Solution (H1374078). The cells were then stained with ICAM1/CD54 Mouse mAb (AF594) (Ab306572) at 5μL/test for 1 hour at 4°C. Left panel - Mouse IgG (AF594) (Ab190247).
ICAM1/CD54 Mouse mAb (AF594) (Ab306572) - Flow Cytometry
Flow cytometry analysis of ICAM1/CD54 expression by human peripheral blood lymphocytes (red) compared to an isotype control (blue). Cells were preincubated with Human Fc Receptor Blocking Solution (H1374078). The cells were then stained with ICAM1/CD54 Mouse mAb (AF594) (Ab306572) at 5μL/test for 1 hour at 4°C. Blue - Mouse IgG (AF594) (Ab190247).
Application
Application
Dilution info
Flow Cytometry
5μl/test
For flow cytometric staining, the suggested use of this reagent is 5 µL per million cells in 100 µL staining volume or 5 µL per 100 µL of whole blood.
Documentation
📋 Safety Data Sheet (SDS)
Comprehensive hazard, handling, storage, and regulatory compliance document.
We use cookies to ensure the website functions properly and, where permitted, to improve your experience. You can manage your preferences at any time in Settings. Learn more in our Cookie Policy.
Shall we send you a message when we have discounts available?
Remind me later
Thank you! Please check your email inbox to confirm.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.