Lactose Assay ELISA Kit - sufficient for 100colorimetricorfluorometrictests, high purity

Cat. No.: L486307
AVAILABLE TO ORDER
GRADE & PURITY 96T
 ·  off list, applied to all prices below.
Size
Status
Price
Qty
1kit
L486307-1kit
8-12 wks(?) Production requires sourcing of materials. We appreciate your patience and understanding.
$855.90
Enter a quantity for the sizes you want to add.
🧪

Why this grade

96T for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Store at 2-8°C Ships Wet ice Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

Overview

This reagent kit is for research purposes only. Purpose of use: This reagent kit is used to determine the content of lactose in serum, plasma, and related liquid samples.
Experimental principle:
This kit applies enzyme-linked immunosorbent assay to determine the level of lactose in the sample. Purified lactose antibodies were coated on a microplate to produce solid-phase antibodies. Lactose was added to the microplate of the coated monoclonal antibody, along with HRP labeled lactose antigens, to compete for binding. After thorough washing, the substrate TMB was added for colorimetry. The depth of sample color is negatively correlated with the content of lactose in the sample. Measure the absorbance (OD value) at a wavelength of 450nm using an enzyme-linked immunosorbent assay (ELISA) reader, and calculate the content of lactose in the sample through a standard curve.
Kit composition:

130times concentrated washing solution20ml×1 bottle8.1Standard S1(80μg/L)0.5ml×1bottle
2Enzyme-linked immunosorbent assay6ml×1 bottle8.2Standard S2(40μg/L)0.5ml×1bottle
3Enzyme labeling coated plate96 holes x 1 pieces8.3Standard S3(20μg/L)0.5ml×1bottle
4Color reagent A solution6ml×1 bottle8.4Standard S4(10μg/L)0.5ml×1bottle
5Color developer B solution6ml×1 bottle8.5Standard S5(5μg/L)0.5ml×1bottle
6Stop solution6ml×1 bottle9Instructions1 copy
7Sample Diluent6ml×1 bottle10Microplate Sealers2 sheets

Specimen requirements:
1. Specimen processing:
(1) After collecting the water sample, it is repeatedly freeze-thawed three times at -20 ℃, and then filtered through glass fiber for future reference
(2) The tissue samples should be extracted using butanol: methanol: water (5:25:70 V: V: V), or extracted according to relevant literature. The experiment should be conducted as soon as possible after extraction. If the experiment cannot be conducted immediately, the specimen can be stored at -20 ℃ for future reference
2. Samples containing NaN3 cannot be detected as NaN3 inhibits the activity of horseradish peroxidase (HRP).
Operation steps:
1. Sample addition: Set up standard wells, blank wells (blank control wells do not include samples and enzyme-linked immunosorbent assay reagents, the other steps are the same), and sample wells to be tested. Add 50 microliters to the standard well on the enzyme-linked immunosorbent assay (ELISA) plate, and first add 40 diluents to the sample well to be tested μ l. Then add 10 more samples to be tested μ L (The final dilution of the sample is 5 times). Add the sample to the bottom of the enzyme-linked immunosorbent assay (ELISA) plate well, avoiding touching the well wall as much as possible. Gently shake and mix well.
2. Enzyme addition: Add 50 enzyme labeled reagents to each well μ l. Excluding blank holes.
3. Warm incubation: Seal the plate with a sealing film and incubate at 37 ℃ for 60 minutes.
4. Solution preparation: Dilute 30 times the concentrated washing solution with distilled water and set aside for later use
5. Washing: Carefully remove the sealing film, discard the liquid, shake dry, fill each well with washing solution, let it stand for 30 seconds, then discard. Repeat this process 5 times and pat dry.
6. Color development: Add color development agent A50 to each well first μ l. Add color developer B50 again μ l. Gently shake and mix well, and develop color at 37 ℃ in the dark for 15 minutes
7. Termination: Add 50% termination fluid to each hole μ l. Terminate the reaction (at this point, the blue color immediately turns yellow).
8. Measurement: Zero the blank hole and sequentially measure the absorbance (OD value) of each hole at a wavelength of 450nm. The measurement should be conducted within 15 minutes after adding the termination solution.

Calculation:
Draw a standard curve on a coordinate paper with the concentration of the standard substance as the x-axis and the OD value as the y-axis. Based on the OD value of the sample, determine the corresponding concentration from the standard curve; Multiply it by the dilution factor; Alternatively, a linear regression equation can be used to calculate the standard curve using the concentration and OD value of the standard substance. The OD value of the sample can be substituted into the equation to calculate the sample concentration, which is then multiplied by the dilution factor to obtain the actual concentration of the sample.
Notes:
1. The kit should be balanced at room temperature for 15-30 minutes before use when taken out from the cold storage environment. If the enzyme coated plate is not used up after opening, the Flat noodles should be stored in a sealed bag.
2. Concentrated detergent may precipitate crystals. When diluted, it can be heated in a water bath to aid in dissolution. Washing does not affect the results.
3. A sampler should be used for each step of sample addition, and its accuracy should be regularly calibrated to avoid experimental errors. It is best to control the sample addition time within 5 minutes. If there are a large number of specimens, it is recommended to use a firing gun for sample addition.
4. Please make a standard curve at the same time as each measurement, preferably with a re hole. If the content of the substance to be tested in the sample is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please dilute the sample diluent by a certain multiple (n times) before measurement. When calculating, please multiply the total dilution multiple (x n x 5).
5. The sealing film is only for one-time use to avoid cross contamination.
6. Please store the substrate in dark.
7. Strictly follow the instructions and determine the test results based on the reading of the enzyme-linked immunosorbent assay (ELISA) reader
8. All samples, washing liquids, and various waste should be treated as infectious substances.
9. The components of this reagent with different batch numbers shall not be mixed.
Detection range:
two μ G/L-90 μ G/L

Storage and Shipping
Storage
Store at 2-8°C
Shipped In
Wet ice

Documentation

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Certificates(CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

1 results found

Lot NumberCertificate TypeDateItem
H2427520Certificate of AnalysisJun 11, 2026 L486307
Solution Calculators
Reviews

Customer Reviews

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.