GRADE & PURITYValidated?Validated grade — performance confirmed in defined applications before release. Use when you want documented assurance the reagent works as stated.ExactAb™?ExactAb™ — Aladdin's antibody line emphasizing precision and validated quality. Use for reliable, specificity-validated antibody applications.See COA
Guanine nucleotide exchange factor (GEF), which can activate some, but not all, G-alpha proteins. Able to activate GNAI1, GNAO1 and GNAQ, but not GNAS by exchanging bound GDP for free GTP. Involved in regulation of microtubule pulling forces during mitoti
Wirtsspezies
Maus
Spezifität
RIC8A
Immunogen
Recombinant full length protein of human RIC8A.
Positive Kontrolle
WB: A431, HeLa, K562, U-2 OS, NIH/3T3 and C6 cell lysates. IHC: Human kidney tissue. IF/ICC: COS7 transiently transfected with pCMV6-ENTRY RIC8A, Hep G2 cells.
Konjugation
Unconjugated
Note
ExactAb™, Validated
SDS-PAGE
150 kDa
Verfahren zur Reinigung
Protein G purified
Konzentration
See COA
Lagerung und Versand
Form
Liquid
Storage
Store at -20°C,Avoid repeated freezing and thawing
Verschickt in
Ice chest + Ice pads
Stabilität und Lagerung
Store at 4℃ short term (1-2 weeks). Store at -20℃ long term (12 months). Upon receipt, it is recommended to aliquot. Avoid freeze/thaw cycle.
Bilder
RIC8A Mouse mAb (Ab125338) - Western Blot All lanes: RIC8A Mouse mAb (Ab125338) at 1/1000 dilution Samples: Lysates at 20 µg per lane Secondary: Goat Anti-Mouse IgG H&L (HRP) (Ab179001) at 1/20000 dilution
Predicted band size: 60 kDa Observed band size: 60 kDa Exposure time: 65.9 s
RIC8A Mouse mAb (Ab125338) - IHC Immunohistochemical staining of paraffin-embedded Kidney tissue within the normal limits using RIC8A Mouse mAb (Ab125338) (Heat-induced epitope retrieval by 10 mM citric buffer, pH 6.0, 100°C for 10 min, Ab125338, Dilution 1/50)
RIC8A Mouse mAb (Ab125338) - IF/ICC RIC8A Mouse mAb (Ab125338) immunofluorescent staining of COS7 cells transiently transfected by pCMV6-ENTRY RIC8A.
RIC8A Mouse mAb (Ab125338) - IF/ICC Immunofluorescent staining of Hep G2 cells using RIC8A Mouse mAb (Ab125338).
Anwendung
Anwendung
Dilution info
WB
1/1000
IF/ICC
1/100
IHC
1/50
Documentation
📋 Safety Data Sheet (SDS)
Comprehensive hazard, handling, storage, and regulatory compliance document.
Wir verwenden Cookies, um die ordnungsgemäße Funktion der Website sicherzustellen und, soweit zulässig, Ihr Nutzererlebnis zu verbessern. Sie können Ihre Einstellungen jederzeit unter „Einstellungen“ verwalten. Weitere Informationen finden Sie in unserer Cookie-Richtlinie.
Shall we send you a message when we have discounts available?
Remind me later
Thank you! Please check your email inbox to confirm.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.