Determine the necessary mass, volume, or concentration for preparing a solution.
The purification kit is a highly efficient and flexible tool specifically designed for high-purity antibody purification from a variety of sample sources (such as serum, ascites, cell culture supernatant, or hybridoma supernatant). Unlike traditional pre-packed column kits, this kit does not include pre-packed columns or chromatography media. Instead, you can select and pack suitable media into empty columns of any scale according to your experimental needs, making it perfectly adaptable for both manual operation and automated purification systems. This product provides a high-concentration Protein A/G purification buffer, offering researchers maximum experimental flexibility to accommodate various empty chromatography columns, gravity-flow columns, or batch purification processes.
| P1456508 | Components | 10T | 50T | Storage | Quantity Per Test |
| P1456508A | Binding buffer(10×) | 50 mL | 250mL | 2-8℃ | 5 mL |
| P1456508B | Elution buffer(5×) | 10 mL | 50 mL | 2-8℃ | 1 mL |
| P1456508C | Neutralizer Buffer | 10 mL | 50 mL | 2-8℃ | 1 mL |
| P1456508D | Coomassie Brilliant Blue Staining Solution | 10 mL | 50 mL | 2-8℃ | 1 mL |
| P1455932E | Regeneration Buffer | 10 mL | 50 mL | 2-8℃ | 10mL (Optional) |
Note: The recommended amount of Purification resin for each test is 2 mL.
Instructions for Use
Prior to use, dilute all component buffers to 1× concentration with deionized water. Specific operations can be adjusted according to the requirements of different purification tools.
I. Sample Preparation
Before purification, clarify hybridoma supernatants, serum, or ascites samples by centrifugation or filtration through a 0.45 μm filter to avoid clogging the purification column and reducing its lifespan.
II. Sample Purification
1. Equilibration
Fill the purification column with 1× Binding Buffer (approximately 15 column volumes) to equilibrate the column, allowing the liquid to drain naturally.
2. Sample Loading
Remove the top cap of the purification column and add the clarified sample to the Protein A purification column, allowing the liquid to drain naturally.
Note: If the antibody concentration in the sample is low or the sample volume is large, increase the number of loading cycles or extend the loading time to improve the binding efficiency between the antibody and the resin.
3. Washing
Fill the purification column with 1× Binding Buffer (approximately 15 column volumes) to wash away unbound impurities, allowing the liquid to drain naturally.
4. Elution
4.1 Prepare several 1.5 mL centrifuge tubes and pre-add 10 μL of Neutralizer Buffer to each tube.
4.2 Add 3 mL of 1× Elution Buffer (approximately 3 column volumes) to each purification column and collect the eluate by gravity. Collect 8 drops (approximately 0.5 mL) per tube and repeat until elution is complete.
5. Dialysis
5.1 Take 2.5 μL of eluate from each tube, mix with 10 μL of Coomassie Brilliant Blue Staining Solution, and observe the gradient change of antibody elution.
5.2 Collect the eluate tubes with high antibody concentration and dialyze against an appropriate buffer to obtain highly purified IgG.
III. Storage of Purification Column
1. After antibody elution, add an additional 2 mL of 1× Elution Buffer to the column to wash away any residual antibody.
2. Fill the purification column with 1× Binding Buffer (approximately 15 column volumes) to equilibrate the column, allowing the liquid to drain naturally.
3. Fill the purification column with 20% ethanol (approximately 15 column volumes) for preservation, allowing the liquid to drain naturally.
4. Add 5 mL of 20% ethanol to the column, cap the top, and seal the bottom cap. Store at 2-8℃ for direct use in subsequent purifications.
IV. Column Regeneration (Optional)
Perform regeneration when a measurable decrease in column performance is observed, following these steps:
1. Add 10 mL of Regeneration Buffer to the column for washing.
2. Add 30 mL of double-distilled water (ddH₂O) to rinse the column thoroughly and remove residual Regeneration Buffer.
3. Add 20 mL of 1× Binding Buffer to wash and equilibrate the resin.
4. Add 15 mL of 20% ethanol for washing, then add 5 mL of 20% ethanol to the column. Cap the top and seal the bottom cap, and store at 2-8℃
| P1456508 | Components | 10T | 50T | Storage | Quantity Per Test |
| P1456508A | Binding buffer (10×) | 50 mL | 250 mL | 2-8℃ | 5 mL |
| P1456508B | Elution buffer (5×) | 10 mL | 50 mL | 2-8℃ | 1 mL |
| P1456508C | Neutralizer Buffer | 10 mL | 50 mL | 2-8℃ | 1 mL |
| P1456508D | Coomassie Brilliant Blue Staining Solution | 10 mL | 50 mL | 2-8℃ | 1 mL |
| P1455932E | Regeneration Buffer | 10 mL | 50 mL | 2-8℃ | 10mL (Optional) |
Note: The recommended amount of Purification resin for each test is 2 mL.
Comprehensive hazard, handling, storage, and regulatory compliance document.
Download SDS →Lot-specific quality data. Enter your lot number to retrieve the exact COA.
Look up COA →Full quality attributes and acceptance criteria for this grade.
View spec sheet →Find and download the COA for your product by matching the lot number on the packaging.
| Lot Number | Certificate Type | Date | Item |
|---|---|---|---|
| Certificate of Analysis | May 29, 2026 | P1456508 |