GRADE & PURITYRecombinant?Recombinant — produced via recombinant expression for defined sequence and consistency. Use for reproducible, animal-free proteins of known origin.Validated?Validated grade — performance confirmed in defined applications before release. Use when you want documented assurance the reagent works as stated.ExactAb™?ExactAb™ — Aladdin's antibody line emphasizing precision and validated quality. Use for reliable, specificity-validated antibody applications.0.5 mg/mL
May act as a physical homophilic interaction molecule between intestinal epithelial cells (IECs) and intraepithelial lymphocytes (IELs) at the mucosal epithelium for providing immunological barrier as a first line of defense against mucosal infection. Pla
Host species
Rat
Specificity
Mouse EpCAM
Immunogen
Glycoconjugates from BALB/c mouse-derived TE-71 medullary thymic epithelial cell line.
Positive Control
Flow Cytometry: 57BL/6 Mouse thymic cells
Conjugation
PE-Cy5
Excitation (nm)
Blue Laser(488nm), Green Laser(532nm), Yellow-Green Laser(561nm)
Emission(nm)
670nm
Ex/Em(nm)
Ex:565nm;Em:670nm
Grade
ExactAb™, Recombinant, Validated
Light Chain Type
kappa
Purification Method
Protein A purified
Concentration
0.5 mg/mL
Storage and Shipping
Storage
Store at 2-8°C,Protected from light,Do not freeze
Shipped In
Wet ice,Do not freeze
Stability And Storage
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Multicolor flow cytometric analysis of EpCAM/CD326 expression on live mouse thymocytes. C57BL/6 mouse thymocytes were stained with CD8 alpha Rat mAb (PE) (Ab181177), Recombinant CD4 Antibody (FITC) (Ab223921) and either Rat IgG (PE-Cy5) (Ab190072; Left panel) or Recombinant EpCAM/CD326 Antibody (PE-Cy5) (Ab223774; Right panel) at 0.3 μg/test. A bivariate pseudocolor density plot showing the correlated expression of CD326 (EpCAM) expression (or Isotype control staining) was derived from CD4- gated events with the forward and side light-scatter characteristics of viable thymocytes.
Application
Application
Dilution info
Flow Cytometry
≤1.0μg/ test
For flow cytometric staining, the suggested use of this reagent is ≤1.0 μg per million cells in 100 µL staining volume.
Documentation
📋 Safety Data Sheet (SDS)
Comprehensive hazard, handling, storage, and regulatory compliance document.
We use cookies to ensure the website functions properly and, where permitted, to improve your experience. You can manage your preferences at any time in Settings. Learn more in our Cookie Policy.
Shall we send you a message when we have discounts available?
Remind me later
Thank you! Please check your email inbox to confirm.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.