Genetic reporters are used commonly in cell biology to study gene expression and other cellular events coupled to gene expression, such as receptor activity, intracellular signal transduction, mRNA processing, protein folding and protein:protein interactions. Firefly luciferase is one of the most commonly used reporter genes in gene expression. It is an extremely sensitive, fast-responding and easy-to-use reporter gene. The chemiluminescence reaction it catalyzes is one of the most sensitive analytical tools for measuring gene expression.
Firefly luciferase is a protein with a molecular weight of approximately 61 kDa. In the presence of ATP, magnesium ions and oxygen, it can catalyze the oxidation of luciferin into oxyluciferin. During the oxidation process of luciferin, bioluminescence with a wavelength of approximately 560 nm is emitted, and this fluorescence can be measured by a chemiluminescence analyzer.
Bio-UltraBio™ One-step Firefly Luciferase Reporter Gene Assay Kit (Lyophilized) is a one-step assay kit for directly measuring the intracellular firefly luciferase activity through chemiluminescence without the need for cell washing or collection. It features high sensitivity and high signal stability. This kit is a different packaging version of [O1375169] Bio-UltraBio™ One-step Firefly Luciferase Reporter Gene Assay Kit (Ready-to-use), and the detection signal intensities of the two are comparable. The signal half-life is approximately 2 hour. The detection reagent in the [O1375169] Bio-UltraBio™ One-step Firefly Luciferase Reporter Gene Assay Kit (Ready-to-use) is supplied as a ready-to-use liquid, offering the advantage of direct use without reconstitution. However, it requires storage at -80°C, and prolonged storage at -20°C may gradually reduce its detection performance.In contrast, this lyophilized powder product remains highly stable when stored at -20°C. For initial use, the firefly luciferase substrate must be reconstituted with the provided firefly luciferase detection buffer.
Precautions
1. For initial use, the firefly luciferase substrate must be reconstituted with the provided Firefly Luciferase Assay Buffer.
2. Repeated freeze-thaw cycles of the reconstituted Firefly Luciferase Substrate Detection Reagent should be minimized. It is recommended to aliquot the solution upon initial reconstitution and store it protected from light at -20°C or -80°C.
3. Avoid prolonged exposure of the reconstituted Firefly Luciferase Substrate Detection Reagent to room temperature.
4. The enzymatic reaction is temperature-sensitive. Both the cell culture plate and the detection reagent must be equilibrated to room temperature prior to assay initiation.
5. Detector Selection: Any instrument capable of measuring chemiluminescence is suitable for use with this kit. However, for identical samples, the background signal and measured values may vary between different detectors. Furthermore, readings obtained from different instruments for the same sample are not directly comparable.
6. To prevent well-to-well crosstalk, the use of opaque white or black cell culture plates is recommended.
Instruction for use
1. Reagent preparation
Completely pour the Firefly Luciferase Detection Buffer into the vial containing the Firefly Luciferase Substrate. Invert the vial several times to fully dissolve the substrate.
Note: If the reconstituted Firefly Luciferase Detection Reagent is not fully used in a single experiment, it is recommended to aliquot it on ice immediately after reconstitution. The remaining aliquots should be stored at -20°C or -80°C.
2. Cell lysis
1) Adherent cells: Do not aspirate the cell culture medium; directly add the detection reagent of the same volume as the medium.
Suspended cells: The same as adherent cells.
2) Recommended usage volume:
Culture Vessel | 96-well plate | 48-well plate | 24-well plate | 12-well plate | 6-well plate |
Culture Medium Volume (μl/well) | 100 | 150 | 200 | 300 | 500 |
Detection Reagent Volume (μl/well) | 100 | 150 | 200 | 300 | 500 |
3) Lyse the cells for 5 minutes at room temperature, either on a microplate shaker or by standing.
3. Sample Addition
Samples in 96-well plates may proceed directly to the subsequent assay. For other sample types, pipette 200 μl of the mixed solution (culture medium + detection reagent) per well into the assay plate.
4.Detection
Initiate the chemiluminescence detector or a multifunctional microplate reader equipped with chemiluminescence functionality. Set parameters according to the instrument manual and experimental requirements, then proceed to measure the signal values.
B1511294 | Components | 100T | 10 × 100T | Storage | Quantity Per Test |
B1511294A | Firefly luciferase detection buffer | 10 mL | 10×10ml | -20℃ | 100μL |
B1511294B | Firefly luciferase substrate | 1 vial | 10 vials | -20℃, Store in the dark. | 100μL (After reconstitution ) |
Comprehensive hazard, handling, storage, and regulatory compliance document.
Download SDS →Lot-specific quality data. Enter your lot number to retrieve the exact COA.
Look up COA →Full quality attributes and acceptance criteria for this grade.
View spec sheet →Find and download the COA for your product by matching the lot number on the packaging.
| Lot Number | Certificate Type | Date | Item |
|---|---|---|---|
| Certificate of Analysis | Apr 17, 2026 | B1511294 |
Our grade selection guide covers purity, stabilizer status, and application suitability for all variants in our catalog.
View BioReagent grade guide → View for Chemiluminescence grade guide →