YUKA1 is a potent and cell permeable Lysine demethylase 5A ( KDM5A ) inhibitor, with an IC 50 of 2.66 μM, less active on KDM5C (IC 50 , 7.12 μM), and is inactive on KDM5B, KDM6A or KDM6B. YUKA1 increases H3K4me3 levels in human cells with anti-cancer activity
Form:Solid
IC50& Target:KDM5
Specifiche
Sinonimi
4-{[(3-methoxy-2-prop-2-enyloxyphenyl)methyl]amino}-1,2,4-triazole-3-thiol | YUKA1 | 4-[(3-methoxy-2-prop-2-enoxyphenyl)methylamino]-1H-1,2,4-triazole-5-thione | 4-({[3-methoxy-2-(prop-2-en-1-yloxy)phenyl]methyl}amino)-4,5-dihydro-1H-1,2,4-triazole-5-thione | 4-{[3-methoxy-2-(prop-2-en-1-yloxy)benzyl]amino}-4H-1,2,4-triazole-3-thiol | 4-( Mostra altro
Specifiche e purezza
≥99%
Meccanismi biochimici e fisiologici
YUKA1 is a potent and cell permeable Lysine demethylase 5A ( KDM5A ) inhibitor, with an IC 50 of 2.66 μM, less active on KDM5C (IC 50 , 7.12 μM), and is inactive on KDM5B, KDM6A or KDM6B. YUKA1 increases H3K4me3 levels in human cells with anti-cancer acti
Condizioni di conservazione di stoccaggio
Store at 2-8°C,Protected from light,Desiccated
Spedito in
Wet ice
Questo prodotto richiede spedizione a catena fredda. I servizi di terra e altri servizi economici non sono disponibili.
This compound belongs to the class of organic compounds known as anisoles. These are organic compounds containing a methoxybenzene or a derivative thereof.
External Descriptors
Not available
1. Djoumbou Feunang Y, Eisner R, Knox C, Chepelev L, Hastings J, Owen G, Fahy E, Steinbeck C, Subramanian S, Bolton E, Greiner R, and Wishart DS. ClassyFire: Automated Chemical Classification With A Comprehensive, Computable Taxonomy. Journal of Cheminformatics, 2016, 8:61.
Certificati (CoA, COO, BSE/TSE e tabella di analisi)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Proprietà chimiche e fisiche
Solubilità
DMSO : 100 mg/mL (342.04 mM; Need ultrasonic)
Peso molecolare
292.36
XLogP3
1.800
Hydrogen Bond Donor Count
2
Hydrogen Bond Acceptor Count
5
Rotatable Bond Count
7
Exact Mass
292.099 Da
Monoisotopic Mass
292.099 Da
Topological Polar Surface Area
90.200 Ų
Heavy Atom Count
20
Formal Charge
0
Complexity
377.000
Isotope Atom Count
0
Defined Atom Stereocenter Count
0
Undefined Atom Stereocenter Count
0
Defined Bond Stereocenter Count
0
Undefined Bond Stereocenter Count
0
The total count of all stereochemical bonds
0
Covalently-Bonded Unit Count
1
Calcolatori di soluzioni
Molarity Calculator
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
Recensioni
Recensioni dei clienti
Application Protocols
No tested application protocols are provided in the product data for YUKA1. The following is general guidance for small-molecule handling in screening contexts (not item-specific; verify experimentally):
Stock preparation:
Dissolve compound in dry DMSO to prepare a 10–50 mM master stock, adjusting as dictated by solubility. Vortex and sonicate gently if needed. Use amber vials to limit light exposure.
Pass solutions through a 0.22 µm PTFE filter if particulate is observed and if the compound is stable to brief filtration.
Working solutions:
Dilute DMSO stocks into assay buffer or media to the desired final concentration. Keep final DMSO ≤0.5–1% v/v unless your assay tolerates more.
Prepare serial dilutions (e.g., half-log) for concentration–response curves, using low-binding tips/plates to minimize adsorption.
Controls and QA:
Include vehicle controls and, if available, appropriate positive/negative control compounds.
Assess stability over the assay timeframe (t0 vs tend by LC–MS/LC–UV) and check for precipitation after dilution.
Data integrity:
Record lot number, stock concentration, solvent composition, and storage history. For repeated use, dispense single-use aliquots to avoid freeze–thaw and evaporation-driven concentration drift.
Biological Roles
Item-specific target, mechanism, or pathway associations are not provided in the product data for YUKA1 (SKU Y651248). Accordingly, no target- or pathway-specific roles can be asserted for this item.
General context for small-molecule research tools (not item-specific):
Small molecules are used to modulate protein function or perturb pathways transiently, enabling time-resolved studies in cells or lysates.
They can assist in phenotypic screening, where measurable cellular outputs (viability, signaling markers, transcriptional readouts) are assessed across concentration ranges.
When a target is known, orthogonal assays (biochemical binding/enzymatic activity, CETSA/DSF, target engagement) help confirm on-target activity versus off-target effects.
Good practice:
Establish compound integrity (purity, identity) before biological testing.
Quantify solubility limits and stability in the chosen assay matrix to avoid artifactual readouts (e.g., precipitation, adsorption, or photodegradation). The product data note to protect from light suggests prudence against potential photosensitivity.
Include vehicle controls and, when applicable, orthogonal probe compounds to benchmark selectivity.
Research-use-only notice:
This product is designated For research use only. No claims are made regarding therapeutic use, diagnostic use, or clinical performance.
Buffer Applications
This product is a small-molecule library member and is not a buffering reagent. Classical buffer system design (pKa matching, ionic strength, capacity) is therefore not typically applicable.
Practical handling in buffered systems (general guidance, not item-specific):
Prepare concentrated stocks in an appropriate organic solvent (commonly DMSO), then dilute into the target buffer (e.g., PBS, HEPES, assay-specific buffer), keeping final organic content ≤0.5–1% where assay-compatible.
Verify that no precipitation occurs upon dilution into buffer. If cloudiness appears, reduce concentration, increase temperature slightly, or add a small proportion of a miscible co-solvent.
Use amberware or reduced light conditions as the item specifies protection from light.
Filter-sterilize working solutions (0.22 µm) if sterility is required for cell-based assays and if the compound is stable to brief filtration.
If buffer compatibility is critical (e.g., for binding assays):
Screen a small matrix of buffers (pH and salt) to identify conditions that maintain compound solubility and assay performance.
Document the exact buffer composition, pH, and final co-solvent percentage for reproducibility.
Green Alternatives
Green chemistry considerations for handling small-molecule library compounds (general guidance; not item-specific):
Solvent choices:
Prefer ethanol or isopropanol over acetonitrile or DMF where compatible with solubility and assay biology.
Use water-based buffers with minimal co-solvent content for working solutions. Keep DMSO at the lowest feasible %.
Operational practices:
Right-sizing aliquots reduces freeze–thaw cycles and waste. Dispense single-use volumes for screening campaigns.
Employ microplate-based formats to minimize solvent volume and energy required for evaporation.
Utilize amber, reusable glassware to reduce plastic waste, especially since the product specifies protection from light.
If synthesis or re-synthesis is planned (general, not specific to this item’s route):
Consider greener solvents such as 2-methyltetrahydrofuran (2-MeTHF) or cyclopentyl methyl ether (CPME) in place of chlorinated solvents, balancing with reaction requirements.
Select catalytic processes over stoichiometric reagents where possible, and design telescoped steps to minimize workups.
Trade-offs:
DMSO remains common for stock solutions due to solubilizing power, but its environmental footprint and persistence warrant careful waste management. Ethanol is greener but may not dissolve hydrophobic chemotypes at required concentrations.
Pharmaceutical Uses
Item-specific pharmaceutical or excipient roles are not provided for YUKA1. This product is supplied for research use only and is not intended for human or veterinary use.
General context (not item-specific):
Small molecules in discovery settings are used as reference standards, tool compounds, or screening hits/leads to inform medicinal chemistry optimization.
Preformulation studies may examine solubility, stability (thermal, oxidative, photolytic), and solid form (polymorph/salt) to guide future development decisions.
Analytical development may include LC–MS quantification, stability-indicating methods, and impurity profiling.
Operational guidance:
If formulation-like vehicles are explored for in vivo research, ensure they are appropriate for the model system and within institutionally approved protocols. No such uses are implied by this listing.
Keep complete records of lot numbers, preparation methods, and storage conditions for any GLP-adjacent work.
Regulatory note:
No pharmacopeial monograph or cGMP manufacture is indicated in the product data. For regulated applications, obtain comprehensive documentation and consider requalification per your QA requirements.
Physical Properties
Item-specific properties (from Product Data):
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
Molecular Weight: Not specified for this item; refer to CoA/Spec Sheet.
Molecular Formula: Not specified for this item; refer to CoA/Spec Sheet.
Melting/Boiling Point, Density, Refractive Index, pKa, logP, UV cutoff: Not specified for this item; refer to CoA/Spec Sheet.
Solubility: Not specified for this item; refer to CoA/Spec Sheet.
General/literature guidance for small-molecule library members (not item-specific):
Many screening compounds are supplied as solids or films and are often soluble in DMSO at 10–50 mM for screening stocks. A small percentage of compounds may require heating or sonication to dissolve.
For aqueous assays, co-solvent systems such as DMSO/water or ethanol/water are commonly used; maintain final DMSO ≤0.5–1% v/v to minimize assay interference.
If UV-Vis or LC–UV detection is planned, determine absorption empirically; library compounds vary widely in chromophores.
Practical recommendations:
Perform a small-scale solubility test (serial addition of solvent with vortex/sonication) and document the maximum practical concentration for your application.
If logP/pKa are required for method development (e.g., LC method or permeability studies), obtain literature/computed values from curated databases for CID 2215170 and confirm against experimental measurements as needed.
For thermolabile or photosensitive compounds, use amber vials and minimize heat/light exposure (see Storage & Reconstitution).
Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.
Stabilizers/Inhibitors: Not specified for this item; refer to CoA/Spec Sheet.
How to interpret grade/purity (general guidance):
For small-molecule screening compounds, suppliers typically report HPLC purity (%), and may include LC–MS identity confirmation and, when relevant, NMR data. In absence of a stated grade (e.g., ≥95% HPLC), confirm via the CoA.
If a stabilizer is present (e.g., acid salt form, antioxidant), it will be disclosed on the CoA/SDS; absence of such a note here means it is not specified for this item.
Best practices for quality control in screening campaigns:
Verify identity and purity on receipt for critical studies (e.g., LC–MS check, quick 1H NMR, or orthogonal methods as your QA requires).
If potency data will be reported, consider reformatting into single-use aliquots to avoid freeze–thaw and concentration drift from evaporation.
Record lot number and maintain chain-of-custody. If UV background or fluorescence interference matters, evaluate blank solvent controls containing the same % of DMSO.
Documentation to consult:
CoA/Spec Sheet for SKU Y651248 (purity, analytical method, residual solvents, water content if available).
Reaction and Applications
Context for this catalog entry:
YUKA1 (SKU Y651248) is categorized under small-molecule/compound libraries. No specific synthetic or mechanistic application is disclosed in the product data.
Research applications (general, not item-specific):
Chemical biology screening: Employed as a test article in biochemical or cell-based assays to probe pathway responses, generate preliminary SAR hypotheses, or benchmark assay performance.
Reference material: Can serve as a control in method development (e.g., LC–MS quantitation, stability studies) once identity/purity are verified.
Phenotypic assays: Used to observe morphological or transcriptional changes at varying concentrations, with appropriate DMSO-matched controls.
Practical tips:
Prepare fresh working dilutions immediately prior to assays to minimize degradation and adsorption losses.
Use low-bind plasticware or glass vials when handling micromolar solutions to reduce nonspecific adsorption.
Given the item note to protect from light, conduct critical steps under reduced light or with amberware.
Include a vehicle control and, if applicable, a positive control compound to contextualize assay responses.
Assay design considerations:
Establish a concentration–response curve (e.g., 8–12 points, half-log dilutions) and define acceptable solvent ceiling (often ≤0.5–1% DMSO).
Confirm compound stability in assay buffer over the assay window (e.g., via LC–MS at t0/tend).
Reaction Conditions
No reaction conditions are specified for YUKA1 in the product data, and the compound is not presented as a reagent for named reactions.
General guidance (not item-specific) if chemical modification is contemplated after structure confirmation:
Choose solvents based on solubility and stability (DMSO, DMF, MeCN, alcohols, or greener ethers such as 2-MeTHF), and match to the intended transformation (e.g., coupling, hydrogenation, oxidation).
Control temperature carefully and monitor by LC–MS or TLC; screening compounds may contain sensitive motifs that degrade with heat, light, or strong acids/bases.
If photolysis is a concern (the item indicates protection from light during storage), conduct reactions under reduced light or use amber glassware.
Because item-specific functional groups, catalysts, and yields are unknown, consult the primary literature associated with the confirmed structure (e.g., via PubChem CID 2215170) and validate on small scale before committing resources.
Safety and Handling
Item-specific hazard information (from Product Data):
GHS Classification: Not specified for this item; refer to SDS.
Signal Word / H-Statements / Pictograms: Not specified for this item; refer to SDS.
General laboratory precautions for small organic molecules (not item-specific; follow your institutional EHS policies):
PPE: Lab coat, safety glasses or goggles, and suitable chemical-resistant gloves (e.g., nitrile). Use in a chemical fume hood to avoid inhalation of dust or vapors.
Avoid exposure: Prevent skin/eye contact and inhalation of dust or aerosols. Handle powders gently to limit airborne particulates. Protect from light as specified.
First aid (general): In case of skin or eye contact, rinse with water for ≥15 minutes. If inhaled, move to fresh air. If ingested, rinse mouth and seek medical attention. Always consult the SDS for the authoritative first-aid guidance.
Incompatibilities: Unknown for this specific item. As a general rule for organic compounds, avoid strong oxidizers, strong acids/bases, and reactive reducing agents unless compatibility is known.
Spill management: For small spills, absorb with inert material and dispose according to local regulations. Prevent release to drains.
Waste: Collect as organic chemical waste. Follow your facility’s hazardous waste procedures.
Documentation:
Obtain and review the SDS for SKU Y651248 before first use. If specific GHS data are required for risk assessment, request the latest SDS/CoA from Aladdin Scientific.
Solvent Selection
Item-specific solubility is not provided in the product data. The following guidance reflects common practice for small-molecule screening compounds (general, not item-specific):
Primary solvent systems:
DMSO (anhydrous): First-line stock solvent for diverse chemotypes; typical stock 10–50 mM. Pros: broad solubility, assay compatibility at ≤0.5–1% v/v. Cons: hygroscopic; can affect biological assays at higher %.
Ethanol or Methanol: Alternative for some assays or analytical sample prep; watch for volatility and assay compatibility.
Acetonitrile: Useful for LC method development and sample dissolution; typically diluted into aqueous mobile phases.
Aqueous compatibility:
For biological assays, prepare final working solutions by diluting DMSO stocks into buffered aqueous media (e.g., PBS, assay buffer). Keep final organic content minimal to avoid perturbing targets/cells.
Selection tips:
Start with dry DMSO for stock preparation. If insoluble, try co-solvents (DMSO:MeOH 1:1) or gentle warming/sonication.
For LC–MS, match the dissolution solvent to starting mobile phase to minimize peak distortion.
If the compound is light-sensitive (product data specifies protection from light), use amber vials and limit light exposure during handling.
Comparison (general):
DMSO vs EtOH: DMSO offers broader solubility; EtOH is greener and more volatile—better for rapid evaporation steps.
MeCN vs MeOH: MeCN provides lower viscosity and stronger elution in RP-HPLC; MeOH is less toxic and more sustainable.
Storage and Reconstitution
Item-specific storage and shipping (from Product Data):
Storage Conditions: Store at 2–8°C, protected from light, desiccated.
Shipped In:Wet ice.
Reconstitution and handling (general guidance, not item-specific):
Allow vials to equilibrate to room temperature in a desiccator before opening to prevent moisture condensation on cold material.
Prepare concentrated stocks in anhydrous DMSO under low light. Typical screening stocks are 10–50 mM; determine the maximum soluble concentration empirically.
Split into single-use aliquots in amber vials/tubes to minimize freeze–thaw and light exposure. Backfill headspace with dry inert gas (N2/Ar) if prolonged storage is anticipated.
Store DMSO stocks at −20°C or −80°C in tightly sealed, moisture-protected containers. Avoid repeated freeze–thaw; discard aliquots showing precipitation or discoloration.
Stability notes:
Specific shelf-life and solution stability are not specified for this item; consult the CoA and monitor by analytical methods (e.g., LC–MS, HPLC) at defined intervals.
Because protection from light is specified, handle and store in amber containers and limit exposure during weighing and transfers.
Labeling:
Clearly mark aliquots with compound name/SKU, lot, concentration, solvent, preparation date, and storage conditions to ensure traceability.
Structure and Identity
Brief description: YUKA1 is listed as a small-molecule library member. Item-specific structural descriptors are not provided in the product data.
Item-specific identifiers (from Product Data):
SKU: Y651248
Product Name: YUKA1
CAS: 708991-09-7
PubChem CID: 2215170
InChIKey: 238569 (as provided; note this is not in typical 27-character format)
SMILES: Not specified for this item; refer to CoA/Spec Sheet.
Molecular Formula: Not specified for this item; refer to CoA/Spec Sheet.
Molecular Weight: Not specified for this item; refer to CoA/Spec Sheet.
Structural features (general note):
Specific functional groups, ring systems, and stereochemistry are not provided in the item record. No 2D/3D structural depiction can be confirmed from the supplied data.
The listed PubChem CID (2215170) may contain a literature structure and computed identifiers; these are not verified for this exact lot/item. Always reconcile with the Aladdin CoA/SDS for this catalog number before use.
Implications for use:
Without an item-verified structure, plan handling and assay design using general small-molecule practices (see Application Protocols and Storage tabs) and confirm structure/identity via the provided CoA or by independent analytical methods (e.g., NMR, LC–MS) if required by your quality system.
Synthetic Utility
Based on the catalog categorization, YUKA1 is offered as a small-molecule library member rather than as a synthetic reagent or building block. The product data do not include functional-group information, leaving its synthetic reactivity indeterminate.
Implications:
It is not typically used as a reagent or intermediate in routine synthesis workflows without confirmed structure and reactivity data.
If you intend to derivatize or use it as a scaffold for SAR expansion, first obtain or confirm the structure (via CoA/SDS or independent characterization) and assess chemical stability under the planned transformation conditions.
General strategies (not item-specific):
For analog generation, common tactics include bioisosteric replacements, heteroatom variation, or substituent scanning on known pharmacophores—contingent on a verified structure.
Analytical support (LC–MS, 1H/13C NMR, HRMS) is recommended for each modified analog to maintain traceable identity.
Conclusion:
Without item-verified structural details, treat YUKA1 primarily as a test article for assays rather than a synthetic handle.
Target Specificity
Target specificity is not provided in the product data for YUKA1 (SKU Y651248).
Per the catalog rules, this section only reports item-specific data. No target, pathway, or selectivity profile is available here. If target information is required for your work, please consult the CoA/Spec Sheet for this item or review validated primary literature corresponding to the confirmed structure. Any biological activity claims should be verified experimentally under your assay conditions.
Domande frequenti
What is the purity of this product?
This product is supplied at ≥99% purity (chemical assay). Lot-specific values are stated on the Certificate of Analysis.
How should this product be stored?
Store at 2–8 °C, protected from light, desiccated. Keep the container tightly closed with desiccant — the material is moisture-sensitive.
How is this product shipped?
This product ships chilled on wet ice. Unpack on arrival and transfer it to the storage condition stated above.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is 708991-09-7, the molecular formula is C13H16N4O2S, and the molecular weight is 292.36 g/mol. InChIKey NHJCZZWENDYDEP-UHFFFAOYSA-N.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.
Utilizziamo i cookie per garantire il corretto funzionamento del sito web e, ove consentito, per migliorare la tua esperienza. Puoi gestire le tue preferenze in qualsiasi momento nelle Impostazioni. Per saperne di più, consulta la nostra Cookie Policy.
Desidera che le inviamo un messaggio quando avremo sconti disponibili?
Ricordamelo più tardi
Grazie! Controlli la sua casella di posta per confermare.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.