Determine the necessary mass, volume, or concentration for preparing a solution.
BioReagent,for chemiluminescence BioReagent,for Chemiluminescence for sensitive chromatographic and analytical workflows requiring minimal baseline interference.
Protected from light,Store at -80°C Ships Dry ice packs + Cold packs Check lot-specific COA for exact specifications.
SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.
Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.
Introduction
Genetic reporters are used commonly in cell biology to study gene expression and other cellular events coupled to gene expression, such as receptor activity, intracellular signal transduction, mRNA processing, protein folding and protein:protein interactions. Firefly luciferase is one of the most commonly used reporter genes in gene expression. It is an extremely sensitive, fast-responding and easy-to-use reporter gene. The chemiluminescence reaction it catalyzes is one of the most sensitive analytical tools for measuring gene expression.
Firefly luciferase is a protein with a molecular weight of approximately 61 kDa. In the presence of ATP, magnesium ions and oxygen, it can catalyze the oxidation of luciferin into oxyluciferin. During the oxidation process of luciferin, bioluminescence with a wavelength of approximately 560 nm is emitted, and this fluorescence can be measured by a chemiluminescence analyzer.
Bio-UltraBio™ One-step Firefly Luciferase Reporter Gene Assay Kit (Ready-to-use) is a one-step assay kit for directly measuring the intracellular firefly luciferase activity through chemiluminescence without the need for cell washing or collection. It features high sensitivity and high signal stability. The kit provides ready-to-use firefly luciferase assay reagents. Just add them to the cell culture plate in an equal volume to the culture medium and react for 5 minutes, then chemiluminescence detection can be carried out. This kit is flexible and convenient to use, with high detection sensitivity and relatively stable luminescence signals. The signal half-life is approximately 2 hour.
Precautions
1. The luciferase detection reagent for fireflies should be avoided from repeated freezing and thawing as much as possible. It is recommended to appropriately aliquot the reagent for the first use and then store it in a dark place at -80°C.
2. The enzymatic reaction is temperature-sensitive. Both the cell culture plate and the detection reagent must be equilibrated to room temperature prior to assay initiation.
3. Detector Selection: Any instrument capable of measuring chemiluminescence is suitable for use with this kit. However, for identical samples, the background signal and measured values may vary between different detectors. Furthermore, readings obtained from different instruments for the same sample are not directly comparable.
4. To prevent well-to-well crosstalk, the use of opaque white or black cell culture plates is recommended.
Instruction for use
1. Cell lysis
1) Adherent cells: Do not aspirate the cell culture medium; directly add the detection reagent of the same volume as the medium.
Suspended cells: The same as adherent cells.
2) Recommended usage volume:
Culture Vessel | 96-well plate | 48-well plate | 24-well plate | 12-well plate | 6-well plate |
Culture Medium Volume (μl/well) | 100 | 150 | 200 | 300 | 500 |
Detection Reagent Volume (μl/well) | 100 | 150 | 200 | 300 | 500 |
3) Lyse the cells for 5 minutes at room temperature, either on a microplate shaker or by standing.
2. Sample Addition
Samples in 96-well plates may proceed directly to the subsequent assay. For other sample types, pipette 200 μl of the mixed solution (culture medium + detection reagent) per well into the assay plate.
3. Detection
Initiate the chemiluminescence detector or a multifunctional microplate reader equipped with chemiluminescence functionality. Set parameters according to the instrument manual and experimental requirements, then proceed to measure the signal values.
Comprehensive hazard, handling, storage, and regulatory compliance document.
Download SDS →Lot-specific quality data. Enter your lot number to retrieve the exact COA.
Look up COA →Full quality attributes and acceptance criteria for this grade.
View spec sheet →Find and download the COA for your product by matching the lot number on the packaging.
| Lot Number | Certificate Type | Date | Item |
|---|---|---|---|
| Certificate of Analysis | May 14, 2026 | O1375169 |
Our grade selection guide covers purity, stabilizer status, and application suitability for all variants in our catalog.