Peptide Desalting Columns (No Reagents Included) - BioReagent, sterile, Proteomics grade

Cat. No.: P1492384
AVAILABLE TO ORDER
GRADE & PURITY BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. Proteomics grade ? Proteomics grade — ultra-clean, low-contaminant reagents for proteomic MS workflows. Use in sample prep for protein identification and quantitation. Sterile ? Sterile grade — processed and verified free of viable microorganisms. Use directly in aseptic procedures and cell culture without further sterilization.
Synonyms
Desalting Column
Storage
Room temperature
Shipped In
Normal
Application
Peptide Desalting, Protein Mass Spectrometry, Proteomic Sample Preparation
 ·  off list, applied to all prices below.
Size
Status
Price
Qty
96T
P1492384-96T
1-2 wks(?)
Item is derived from our semi-finished stock and is processed in 1-2 weeks.
$279.90
Enter a quantity for the sizes you want to add.
🧪

Why this grade

BioReagent, sterile, Proteomics grade BioReagent,Proteomics grade,Sterile for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Room temperature Ships Normal Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

Overview

Working principle of the desalting column: It distinguishes different substances according to their molecular sizes. Due to the obvious difference in size between salt molecules and the target molecules in the sample (such as proteins), the separation of target molecules from salt molecules can be achieved.


Schematic diagram of the operation process


Product Components and Storage Conditions:

Item Number
Component
96T
Storage
P1456352A
Peptide Desalting Columns
96T
RT
P1456352B
Collection Tube
30个RT

Supplementary Reagents* (If desalting reagents are not available, please contact our company to purchase. Catalog No.: H1456342)


Operating Procedure:

① Add 320μL of Wash buffer 1 to the sample after enzymatic hydrolysis, shake vigorously for 3 minutes, centrifuge at 15000rpm for 3 minutes, and remove the upper liquid.
② Transfer the lower layer sample into the Tip column, centrifuge at 2500rpm for 3-5 minutes until all the liquid is centrifuged down. If the liquid flow rate is slow, the rotation speed can be increased.
③ Add 200μL of Wash buffer 2 (shake for 10-20 seconds before use) to the desalting column, centrifuge at 2500rpm for 3-5 minutes until all the liquid is centrifuged down.
④ Add 200μL of Wash buffer 3 to the desalting column, centrifuge at 2500rpm for 3-5 minutes until all the liquid is centrifuged down.
⑤ Put the desalting column into a new EP tube, add 200μL of Elution buffer to the desalting column, centrifuge at 2000rpm for 3-5 minutes until all the liquid is centrifuged down.
⑥ Repeat step ⑤, collect the eluates from both times, and freeze-dry them.
⑦ Add 10μL of Loading buffer, vortex vigorously for 3 minutes, centrifuge at 20000g for 10 minutes, take an appropriate amount of sample for mass spectrometry detection. Taking the HF-X instrument as an example, 0.5-1μg of sample is sufficient for loading.


Precautions and Disclaimer:

1.During the sample loading process, the packing in the desalting column must be kept moist.
2.If the sample contains a high concentration of salt (such as 2M urea or >100nM sodium bicarbonate), repeat the rinsing step 1-2 times.
3.This product is for one-time use only; multiple uses are not recommended.
4.This product is limited to scientific research use by professional personnel, and must not be used for clinical diagnosis or treatment, nor for food or drugs.



Specifications

Synonyms
Desalting Column
Specifications & Purity
BioReagent, sterile, Proteomics grade
Stability And Storage
Store at room temperature long term (12 months).
Storage
Room temperature
Shipped In
Normal
Grade
BioReagent, Proteomics grade, Sterile

Documentation

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Certificates(CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Chemical and Physical Properties
SensitivityLight-sensitive
Documents & Articles
Solution Calculators
Reviews

Customer Reviews

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.