Anticancer agent 119 (compound 15) is an N-acylated ciprofloxacin derivative, which has certain antibacterial activity and induces ROS production to promote cancer cell apoptosis.
Specifications
Storage
Store at -20°C
Shipped In
Ice chest + Ice pads
This product requires cold chain shipping. Ground and other economy services are not available.
Names and Identifiers
Molecular Weight
455.40
Advanced Data
Certificates (CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Solution Calculators
Molarity Calculator
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
Reviews
Customer Reviews
Application Protocols
Item-specific, tested application protocols and recommended dilutions are not provided in the Product Data.
General workflow for deploying small-molecule tool compounds in vitro (not item-specific):
Stock solution: Dissolve in dry DMSO to 10–20 mM. Vortex/sonicate and, if needed, warm gently (≤40°C). Record exact concentration.
Working dilutions: Prepare serial dilutions in assay buffer/media to maintain a constant final DMSO level (commonly 0.1–0.5% for cell assays). Include vehicle controls and known reference inhibitors where applicable.
Exposure: Typical incubation times range from 1–72 h depending on pathway kinetics; conduct time‑course studies to optimize.
Readouts: Combine viability/apoptosis assays with pathway‑specific biomarkers to distinguish cytostasis/cytotoxicity from target‑mediated effects.
Data quality: Use triplicate technical replicates and at least three biological replicates. Monitor precipitation or color/fluorescence interference.
These steps are general best practices and are not validated specifically for this item.
Biological Roles
Item-specific biological information:
Target, pathway, and MoA: Not specified for this item; refer to CoA/technical datasheet.
General considerations for oncology research tool compounds (not item-specific):
Small molecules labeled as “anticancer agents” in research catalogs are typically used to probe cancer‑relevant pathways (e.g., kinase signaling, epigenetic regulation, apoptosis, DNA damage response). Without target disclosure, the compound should be treated as a phenotypic modulator until mechanism is confirmed experimentally.
Recommended practices:
Perform orthogonal readouts (e.g., viability plus pathway‑specific biomarkers) to distinguish on‑target effects from general cytotoxicity.
Establish selectivity by counter‑screening in non‑transformed cells or alternate pathway reporters.
Evaluate time‑dependence (acute vs chronic exposure) and reversibility (washout studies) to infer binding mode or downstream adaptation.
ADME/PK in vitro (general):
Assess stability in assay media and microsomes/hepatocytes if translational studies are planned. Determine permeability (PAMPA/MDCK) and plasma protein binding; measure solubility at relevant pH values.
Off‑target risk management:
Monitor for pan‑assay interference (PAINS) behavior and redox/covalent reactivity using appropriate filters and counterscreens (e.g., ALDH, thiol reactivity, fluorescence interference tests).
No clinical or therapeutic claims are made. This product is supplied strictly for research use only.
Buffer Applications
This product is not a buffering reagent, and no pKa or acid/base functionality is provided in the Product Data. Consequently, there are no item‑specific buffer recipes or recommended buffering ranges.
General guidance (not item-specific):
If dissolution into aqueous buffer is required for biological assays, prepare a concentrated DMSO stock, then dilute into assay buffer (e.g., PBS, HEPES, or cell culture media) maintaining a consistent final vehicle percentage across conditions.
For poorly soluble compounds, consider:
Cosolvent systems (e.g., 0.1–0.5% DMSO, optionally with ≤0.1% Tween‑80 if biologically acceptable).
Cyclodextrin inclusion (e.g., 1–10% w/v HP‑β‑cyclodextrin) to enhance apparent solubility.
pH adjustment only if the compound’s ionizable groups are known; without pKa data, avoid speculative pH manipulation that may cause instability or aggregation.
Refer to your assay’s validated buffer system and verify absence of precipitation by visual inspection or nephelometry after dilution.
Green Alternatives
Item-specific environmental attributes: Not specified for this item; refer to SDS/CoA.
General greener-practice guidance for handling bioactive small molecules (not item-specific):
Solvent choice:
Prefer DMSO or ethanol over DMF/NMP when solubility and biology permit; they offer lower reproductive toxicity profiles and simpler waste handling.
For chromatographic purification or analytics, consider MeOH/H2O or EtOH/H2O systems instead of acetonitrile where feasible.
Process scale: keep quantities at the minimum needed for screening to reduce waste inventory and disposal burden.
Energy and storage:
Consolidate cold‑storage usage by aliquoting into volumes that match experimental cadence, reducing repeated freeze–thaw and waste from degraded material.
Use amber vials to avoid photodegradation, reducing the need for repeated re-synthesis or re‑ordering.
Waste management:
Segregate halogenated from non‑halogenated organic waste streams; avoid unnecessary halogenated solvents unless required by solubility/stability.
Comparative snapshot (general):
DMSO: high solvency, miscible with water; broadly accepted in bioassays; higher boiling point can complicate removal but often not required for in‑well dosing.
Ethanol: renewable sources available; volatile; limited solubility for very lipophilic compounds.
DMF/NMP: strong solvency but higher EHS concern; use as last resort and in small volumes with strict exposure controls.
Note: Because the structure and hazard profile are not provided, tailor green selections to your institutional solvent policies and assay compatibility.
Pharmaceutical Uses
Item-specific pharmaceutical/formulation status:
Pharmacopeial status (USP/EP/JP), excipient grade, and GMP compliance: Not specified for this item; refer to CoA/Spec Sheet.
Positioning (general, not item-specific):
This product is supplied strictly for research use only and is not intended for diagnostic, therapeutic, or clinical use. No medical claims are made.
In drug discovery contexts, compounds of this type may be used as reference or tool molecules in preclinical research to benchmark pathways, validate targets, or construct SAR. Any formulation information would be bespoke to internal R&D and is not implied by this catalog listing.
Formulation considerations for research (general):
For in vitro studies, DMSO stocks diluted into media are standard. For ex vivo or exploratory in vivo work within permitted research settings, vehicle selection (e.g., 10–20% PEG400, 5–10% Solutol HS‑15, or cyclodextrin solutions) should follow institutional IACUC/Ethics guidance, with full characterization of solubility and stability. These examples are not item‑specific and require suitability assessment.
Regulatory note:
Absence of GMP documentation and pharmacopeial monographs indicates the material should not be used in human or veterinary applications. Always consult your QA for intended use classification.
Physical Properties
Item-specific properties (from Product Data):
Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
Melting point, boiling point, density, refractive index, pKa, logP/logD, and solubility: Not specified for this item; refer to CoA/Spec Sheet.
General/literature guidance for small-molecule screening compounds (not item-specific):
Many drug-like research compounds are solids at ambient temperature with moderate lipophilicity (typical logP 1–5, literature) and exhibit highest solubility in polar aprotic solvents (DMSO, DMF) and alcohols (MeOH/EtOH). However, properties vary widely with structure; do not assume without confirmation.
If no solubility data are supplied, a standard screening sequence can be used to establish working concentrations: DMSO → DMF → MeOH/EtOH → aqueous buffers with co-solvent or cyclodextrin. Determine the maximal non-precipitating concentration by visual inspection and nephelometry where available.
Hygroscopicity, polymorphism, and hydrate/solvate formation can affect measured properties and assay outcomes; evaluate by TGA/DSC and PXRD when critical.
Analytical characterization tips (general):
Record a lot-specific UV–Vis spectrum (200–400 nm) for impurity/photostability monitoring; measure water content by Karl Fischer when moisture sensitivity is suspected. For salts, determine counter‑ion content by ion chromatography or titration.
Quality & Grades
Item-specific quality details:
Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.
Stabilizer/Inhibitors: Not specified for this item; refer to CoA/Spec Sheet.
General guidance on grades for screening compounds (not item-specific):
Research grade screening compounds are typically supplied at ≥95% purity by HPLC/UPLC (UV at multiple wavelengths). Some discovery programs require ≥97–98% purity; verify acceptance criteria with your QC.
Identity confirmation is commonly supported by 1H NMR, LC‑MS/HRMS, and, when relevant, 13C NMR and elemental analysis. Enantiopure materials may include chiral HPLC data.
Low-UV-absorbing solvent residuals and counter‑ion composition (for salts) can affect bioassays and analytics; review residual solvent testing and salt speciation.
Stabilizers: If the compound is air-, light-, or moisture‑sensitive, suppliers may include stabilizers or package under inert gas. The presence of stabilizers can influence certain assays (e.g., redox or radical assays); confirm whether any are present in this item’s CoA.
Recommendations for incoming QC (best practice):
Perform lot verification on receipt: appearance, LC/MS purity, and identity.
Archive supplier CoA and, if your workflows are stability-sensitive, run accelerated stability checks (e.g., 40°C/75% RH, light exposure) to qualify plate storage conditions.
If using for SAR, ensure consistent salt form and hydrate state across lots.
Reaction & Applications
Item-specific application notes from manufacturer: Not provided in Product Data.
Context and general use (not item-specific):
“Anticancer agent 119” is presented as a research-use small molecule within a screening/compound library. Such compounds are commonly used as tool molecules for pathway interrogation, target validation, phenotypic screening, and SAR benchmarking in oncology-relevant models.
Practical guidance for research deployment:
Stock preparation: make concentrated DMSO stocks (e.g., 10–20 mM) under dry, low-light conditions. Determine solubility limits empirically and document.
Assay dilution: titrate across a logarithmic range (e.g., 10‑point, 3‑fold serial dilutions) ensuring constant vehicle % across wells. Include vehicle and positive/negative controls.
Plate handling: minimize freeze–thaw cycles by aliquoting; use low‑binding polypropylene when adsorption is suspected. Seal plates with solvent‑resistant films to reduce evaporation and edge effects.
Analytical verification: confirm dosing concentration by LC‑UV or LC‑MS of working solutions, especially for long incubations where adsorption or degradation may occur.
Light/air sensitivity: if unknown, adopt conservative precautions—amber vials, desiccant, inert gas headspace.
Not typically used as a synthetic reagent:
Without structural information, catalysis or transformation roles cannot be recommended. For synthetic chemistry applications, obtain the structure and functional‑group profile before planning reactions.
Reaction Conditions
Item-specific reaction conditions: Not applicable—this product is not presented as a reagent, and no structural or functional-group information is provided in the Product Data.
General guidance for handling in solution (not item-specific):
Prepare concentrated DMSO stocks (e.g., 10–50 mM) under dry conditions; verify complete dissolution by inspection and, if available, nephelometry.
For biological testing, conduct serial dilutions to achieve a relevant concentration range, maintaining constant vehicle percentage across samples.
If stability is unknown, minimize exposure to heat and light; use amber vials and store under inert gas when practical.
Confirm stability over experimental timeframes by LC‑MS or HPLC.
If you intend to use this material in a chemical reaction, first obtain and review its structure and conduct small‑scale compatibility tests; do not extrapolate from unrelated compounds.
Safety & Handling
Item-specific safety information:
GHS Classification, Signal Word, Pictograms, and H‑Statements: Not specified for this item; refer to SDS.
Storage condition: Store at −20°C (Product Data).
General safety guidance (not item-specific; always defer to SDS):
Treat as a research-only small molecule of unknown toxicity. Handle in a certified chemical fume hood. Avoid inhalation of dust/aerosols and contact with skin/eyes.
Personal protective equipment (PPE): lab coat, safety glasses or face shield, and appropriate chemically resistant gloves (e.g., nitrile). Consider double-gloving for prolonged handling or when using strong solvents.
Good hygiene: avoid eating/drinking in lab; wash hands thoroughly after handling. Use dedicated tools to minimize cross-contamination in screening libraries.
Spill response: contain solids with damp, inert absorbent; for solutions, absorb with appropriate materials. Clean area with compatible solvent/detergent; dispose as hazardous organic waste.
Fire safety: if formulated or dissolved in flammable solvents (DMSO, DMF, alcohols), keep away from ignition sources; use CO2, dry chemical, or foam extinguishers as appropriate to the solvent.
Incompatibilities: Without structure, specific incompatibilities cannot be listed. As a precaution, segregate from strong oxidizers and acids/bases until compatibility is known.
First aid (overview): in case of skin/eye contact, rinse with water for ≥15 minutes; if inhaled, move to fresh air; if ingested, seek medical attention. Provide the SDS to responders.
Always consult the product SDS and your institutional EHS procedures for authoritative instructions.
Solvent Selection
Item-specific solvent data: Not specified for this item; refer to CoA/Spec Sheet.
General solvent strategy for small-molecule bioactives (not item-specific):
Primary solvent: DMSO is the standard for preparing high‑concentration stock solutions (10–50 mM) due to broad solubilizing power and assay compatibility at low final %.
Secondary options: DMF (higher solvency but less biocompatible), ethanol or methanol (useful for moderately lipophilic compounds), acetonitrile (miscible, volatile), or PEG400/propylene glycol for difficult cases. For aqueous delivery, consider co-solvent systems (e.g., 2–10% DMSO in PBS) or solubilizers (HP‑β‑cyclodextrin).
Decision tree:
Attempt dissolution in dry DMSO with vortex/sonication.
If insoluble, warm gently (≤40°C) and/or switch to DMF, then back-dilute with DMSO.
For biological assays, dilute DMSO stocks into media ensuring final DMSO ≤0.1–0.5% (cell‑based) or per assay tolerance.
Practical tips:
Verify solubility visually and, if available, by nephelometry; avoid hidden precipitation upon dilution (“crash‑out”).
Filter 0.22 µm if particulate forms and the compound is not adsorptive; otherwise, centrifuge and use supernatant.
Record precise solvent lot and water content, as hygroscopic uptake affects concentration.
Comparison (general):
DMSO (dielectric ~47, miscible with water; widely biocompatible) vs DMF (dielectric ~38, potent solvent but less favored biologically). Choose ethanol when volatility/removal is desired and solubility allows.
Storage & Reconstitution
Item-specific instructions (from Product Data):
Storage Conditions: Store at −20°C.
Shipping: Ice chest + ice pads.
Additional item-specific details (appearance, stabilizers, salt form, concentration): Not specified for this item; refer to CoA/Spec Sheet.
General best practices for small-molecule storage (not item-specific):
On receipt, allow the sealed container to equilibrate to room temperature before opening to prevent condensation. If moisture sensitivity is suspected, handle under dry air or inert gas.
Aliquot immediately into single‑use or short‑term vials to minimize freeze–thaw cycles. Use amber vials if light sensitivity is possible.
For solid material: store desiccated at −20°C. For DMSO solutions: store at −20°C; avoid repeated freeze–thaw; check for crystallization or precipitation upon cooling and redissolve gently at room temperature if needed.
Reconstitution (typical for screening compounds): dissolve in anhydrous DMSO to prepare a 10–50 mM stock. Confirm complete dissolution by inspection; filter only if the compound is not adsorptive.
Stability monitoring: periodically verify by LC‑MS/HPLC for degradation, especially after >6 months frozen storage or if multiple thaw cycles occur.
Always follow your institution’s chemical hygiene plan and consult the lot‑specific CoA/SDS for authoritative guidance.
Structure & Identity
Concise identity overview for Anticancer agent 119 (SKU A1418465).
Item-specific (from Product Data):
SKU: A1418465
Product Name: Anticancer agent 119
CAS: 2928614-16-6
Storage: Store at −20°C
Shipping: Ice chest + ice pads
Research Use: For research use only
Not specified for this item; refer to CoA/Spec Sheet:
Molecular formula
Molecular weight
SMILES
InChIKey
IUPAC/Chemical name
Stereochemistry and structural features
2D structure description:
Not available for this item; no structural identifiers were provided in the Product Data. Without a structure (SMILES/InChI), functional-group analysis and ring-system description cannot be generated. Please consult the CoA/Spec Sheet or request structural information from Aladdin Scientific if your application requires structural verification (e.g., for docking, SAR, or analytical method development).
Identity best practices (general guidance):
Verify lot identity by orthogonal methods when structure is known: HRMS (mass accuracy ≤5 ppm), 1H/13C NMR, and HPLC/UPLC purity profiling with UV and, if needed, ELSD/Charged Aerosol Detector.
For screening compounds, maintain a reference of lot-specific spectra and chromatograms in your ELN to support reproducibility across campaigns.
Synthetic Utility
Item-specific functional groups and reactivity: Not specified for this item; structural information is not provided.
General commentary (not item-specific):
Without a known structure, this material should not be assumed to function as a reagent, building block, or ligand in synthetic chemistry. Many bioactive screening molecules contain multiple functional groups (e.g., heteroaromatics, amides, sulfonamides) that could, in principle, undergo derivatization; however, the feasibility and selectivity depend on the actual scaffold.
Recommendations if synthetic modification is desired:
Obtain full structural disclosure (SMILES/InChI) and confirm identity by NMR/HRMS.
Map functional-group compatibility via small‑scale scouting reactions; assess stability toward acids/bases, oxidants/reductants, and common coupling conditions.
If chiral, determine enantiopurity and absolute configuration; plan for stereospecific transformations or racemate resolution as needed.
Consider late‑stage functionalization strategies (C–H activation, Minisci, photoredox) only after confirming the scaffold’s tolerance and avoiding degradation that could confound biological data.
Until structure is available, treat the compound as a finished tool molecule rather than a synthetic intermediate.
Target Specificity
Item-specific target data (required to report antigen/epitope/clone/isotype for biologics) are not applicable to this small-molecule product. No target, binding partner, or enzyme selectivity data are provided in the Product Data.
General note (not item-specific):
For small molecules labeled as anticancer research agents, target specificity—when known—is typically established via biochemical assays (IC50/Ki), cellular target engagement (e.g., CETSA, NanoBRET), and counterscreens against off‑targets. In absence of such data, treat the compound as having unknown specificity and validate in your system of interest.
Frequently Asked Questions
How should this product be stored?
Store at ?20 °C. Freezer storage is required to maintain the specified shelf life.
How is this product shipped?
This product ships in an insulated container with ice pads. Unpack on arrival and transfer it to the storage condition stated above.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is 2928614-16-6, the molecular formula is C21H21F4N3O4, and the molecular weight is 455.40 g/mol.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.
We use cookies to ensure the website functions properly and, where permitted, to improve your experience. You can manage your preferences at any time in Settings. Learn more in our Cookie Policy.
Shall we send you a message when we have discounts available?
Remind me later
Thank you! Please check your email inbox to confirm.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.