Bromide Ion Selective Electrode Solutions - Fill Solution

Cat. No.: I123775
AVAILABLE TO ORDER
GRADE & PURITY Fill Solution
Storage
Room temperature
Shipped In
Normal
★
Size
USA
Germany (EU)*
Price
Qty
125ml
I123775-125ml
2 In stock
—

$71.90

$93.90
Save $22.00 (23.43%)
Enter a quantity for the sizes you want to add.
🧪
Why this grade

Fill Solution for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Room temperature Ships Normal Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

Specifications

Specifications & Purity
Fill Solution
Storage
Room temperature
Shipped In
Normal

Documentation

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Certificates(CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

2 results found

Lot NumberCertificate TypeDateItem
F1511021Certificate of AnalysisAug 13, 2026 I123775
K2103047Certificate of AnalysisAug 04, 2026 I123775
Documents & Articles
Solution Calculators
Reviews

Customer Reviews

Application Protocols

General potentiometric protocol for bromide ISE (literature/good practice; not specific to this SKU):

  • Preparation:

    • Allow all solutions (standards and samples) to equilibrate to the same temperature.
    • Rinse the bromide ISE and reference electrode with deionized water; blot gently.
    • If required by your method, add the ionic strength adjuster (ISA) in a consistent volume fraction to all standards and samples.
  • Calibration:

    • Prepare at least 3–5 bromide standards spanning the expected concentration range.
    • Immerse electrodes in each standard with gentle stirring. Wait for a stable potential (drift <0.2 mV/s, typical) and record.
    • Plot E vs log concentration or use the instrument’s calibration routine to obtain slope and intercept. Verify near‑Nernstian slope (~59 mV/decade at 25 °C for Br−).
  • Measurement:

    • Measure unknowns under the same conditions as standards. For complex matrices, use standard additions to account for activity coefficient differences.
    • Rinse and blot electrodes between measurements to prevent carryover.
  • Quality control:

    • Re‑check a mid‑range standard every 10–15 samples; recalibrate if the reading deviates beyond your QA limits.
    • Document lot numbers, preparation dates, and any dilutions made.
  • Maintenance:

    • Store the bromide ISE per manufacturer guidance; avoid prolonged dry storage of hydrated membranes. Refresh reference filling solution as recommended.

For item‑specific concentrations, ISA composition, and shelf life, consult the CoA/Spec Sheet.

Biological Roles

This section provides general biochemical context about bromide; it is not a claim about this product’s composition beyond its intended analytical role.

  • Bromide (Br−) in biology (literature/general):
    • Naturally occurring halide in seawater, extracellular fluids, and some foods. In organisms, bromide behaves similarly to chloride in terms of distribution but is typically present at much lower concentrations.
    • Bromide can participate in peroxidase‑mediated halogenation chemistry in certain organisms and has been implicated as a required cofactor for collagen IV sulfilimine bond formation in some model systems. Specific physiological roles and requirements vary by species.
    • Analytical determination of bromide in biological matrices (serum, urine, tissue digests) is commonly performed by ISE, IC, or ICP techniques, with careful control of interferences.

Lab practice notes (general):

  • For biological samples, matrix effects are significant; use standard additions or matrix‑matched standards to achieve accurate potentiometric measurements.
  • Avoid oxidizing preservatives that could convert bromide to bromine species; store digests/extracts in neutral, oxygen‑limited conditions when feasible.

Reminder: This product is for research use only and not for clinical diagnostic or therapeutic use.

Buffer Applications

These are bromide ISE solutions intended for calibration/measurement rather than buffering. They are not commonly used to set or maintain pH like classical buffers (PBS, Tris, acetate).

Practical note (general):

  • If your bromide method specifies an ionic strength adjuster (ISA) with buffering capacity, follow the electrode manufacturer’s procedure. The exact composition and buffering range for this SKU are not specified; consult the CoA/Spec Sheet if applicable.
Green Alternatives

While aqueous bromide ISE solutions are already water‑based and generally low in hazard, greener analytical choices can be considered depending on your lab’s goals. The exact environmental profile of this SKU is not specified; consult the SDS/CoA.

Options and trade‑offs (literature/general):

  • Aqueous ISE vs. argentometric titration (AgNO3):

    • Greener aspects: ISE avoids silver‑containing waste and indicators such as dichlorofluorescein.
    • Trade‑offs: ISE requires calibration standards and careful control of interferences (Cl−, I−).
  • ISE vs. ion chromatography (IC):

    • Greener aspects: ISE typically consumes less energy and eluent and generates less hazardous waste than IC systems that use carbonate or hydroxide eluents and suppressors.
    • Trade‑offs: IC provides multi‑analyte separation and lower detection limits but requires more infrastructure and generates cartridge/eluent waste.
  • Reuse and waste minimization:

    • Prepare only the volume of standards needed for the day; avoid large‑batch disposal.
    • Use closed containers and clean dispensing to extend shelf life and reduce contamination.
    • Segregate halide‑containing aqueous waste for potential treatment or minimization per local regulations.

Sourcing considerations:

  • Prefer solutions with documented traceability and long stability at room temperature to reduce cold‑chain energy use. Verify that packaging is recyclable where possible.
Pharmaceutical Uses

Not a pharmaceutical excipient product. These solutions are intended for analytical potentiometry (research and quality-control contexts) rather than formulation. No pharmacopeial monograph or excipient grade is specified for this item; refer to CoA/Spec Sheet if regulatory traceability is required for your application.

Physical Properties

Item-specific physical constants are not provided for this product. Do not treat the following as specifications.

  • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
  • Density, pH, conductivity, refractive index: Not specified for this item; refer to CoA/Spec Sheet.
  • Boiling point / melting point: As aqueous solutions, typical behavior follows water with boiling near ~100 °C and freezing near ~0 °C, modulated by dissolved salt content (literature, general behavior). Exact values are formulation‑dependent and not specified.
  • Solubility: Bromide salts such as NaBr and KBr are highly water‑soluble (literature). This product is an aqueous solution, fully miscible with water. Compatibility with organic solvents is use‑case dependent; see Solvent Selection.
  • Vapor pressure: Governed by water activity; increased solute concentration lowers vapor pressure (Raoult’s law; literature). Item‑specific values not specified.
  • Ionic strength / bromide activity: Critical to ISE calibration and measurement but not specified for this item; consult CoA/Spec Sheet for exact standard concentrations if provided.

Practical notes (general):

  • Temperature strongly affects ISE response (Nernstian slope). Use a constant temperature bath or perform automatic temperature compensation when characterizing physical response.
  • Avoid contamination that alters ionic strength or introduces interfering ions (e.g., Cl−), as it can change effective activity coefficients and measured potentials.
Quality & Grades
  • Grade/Purity: Not specified for this item; refer to CoA/Spec Sheet.

Guidance on typical attributes for ISE solutions (literature/good practice; not item‑specific):

  • Calibration standards: Usually prepared from high‑purity bromide salts with gravimetric or volumetric accuracy, and may be traceable to national metrology institutes. Concentrations are commonly expressed in molarity or mg/L Br−. Low levels of interfering ions (Cl−, I−, S2−, CN−) are critical for reliable response.
  • Ionic Strength Adjuster (ISA): When used, the ISA fixes background ionic strength to minimize activity coefficient variations across standards and samples. ISA composition varies by method; exact composition for this SKU is not specified.
  • Filling/reference electrode solutions: Formulated to match reference system requirements (e.g., KNO3, KCl) while minimizing junction potentials in bromide measurements. Not specified for this item.
  • UV transparency/HPLC suitability: Typically irrelevant for potentiometry; no UV cutoff claims should be inferred.

Documentation and release testing (what to look for on CoA):

  • Labeled bromide concentration(s), uncertainty, and preparation date/lot.
  • Conductivity or ionic strength verification.
  • pH range and absence of specified interfering ions.
  • Shelf‑life and storage guidance consistent with stability of halide standards.
Reaction & Applications

This product is for analytical electrochemistry, not for synthetic reactions. The primary application is potentiometric determination of bromide activity using a bromide ion‑selective electrode.

Analytical applications (literature/general):

  • Direct calibration: Construct a calibration curve (E vs log a_Br−) using at least 3–5 standards spanning the sample range. Typical slopes near 59.16 mV/decade at 25 °C indicate Nernstian behavior.
  • Standard addition: Recommended for complex matrices (e.g., seawater, high TDS brines) to compensate for matrix effects on activity coefficients.
  • Ion exchange and process monitoring: Track bromide in halogenation processes, photographic effluents, or hydrometallurgy streams.
  • Titrimetric endpoint detection: Use a bromide ISE to follow argentometric titrations when chloride interference is managed.

Interferences and selectivity (general):

  • Halides: I− typically interferes (more lipophilic), Cl− to a lesser extent; selectivity coefficients depend on the membrane. Avoid significant levels of S2−, CN− which can complex or poison membranes/reference systems.
  • Oxidants: Free chlorine or bromine consume Br−; neutralize before measurement.

Practical tips:

  • Rinse electrode between standards, blot (do not wipe) to avoid static and junction disturbance.
  • Stir gently and allow adequate equilibration time; record stable potentials.
  • Use ISA as recommended by your electrode manufacturer to stabilize ionic strength and pH.
Reaction Conditions

As an analytical product, relevant “conditions” refer to potentiometric measurement parameters rather than chemical reactions. The following are literature‑based general guidelines; they are not specifications for this item.

  • Calibration: Prepare a series of bromide standards bracketing the expected sample concentration (e.g., 1×10−4 to 1×10−1 M). Record potentials after stabilization and plot E vs log a_Br−. Ideal slope at 25 °C is ~59 mV/decade for a monovalent anion.
  • Temperature: Maintain constant temperature (±0.5 °C). If using ATC (automatic temperature compensation), ensure it is activated and calibrated.
  • Ionic strength adjuster (ISA): Use per electrode manufacturer’s guidance to equalize background ionic strength; composition varies by method.
  • pH: Most bromide ISEs operate over a broad pH (approximately 2–12), avoiding extremes that attack the membrane or reference junction (literature, model‑dependent). Oxidizing conditions or strong acids in the presence of oxidants can generate Br2, depleting Br−.
  • Interferences: I− > SCN− > Cl− are common interfering anions; apply selectivity corrections (Nicolsky–Eisenman) or mitigate by masking, sample pretreatment, or standard addition.
  • Equilibration: Allow adequate time (typically seconds to a few minutes) with gentle stirring; avoid air bubbles on the membrane.
  • Reference system: Use a stable double‑junction reference to minimize junction potentials when measuring high halide matrices (general best practice).
Safety & Handling
  • GHS/CLP status: Not specified for this item; refer to the SDS for authoritative hazard classification, signal word, pictograms, and H‑statements.
  • Storage conditions (from Product Data): Store at room temperature. Ship under normal conditions. Protect from contamination and evaporation. Keep containers tightly closed when not in use.
  • General hazards (literature/guidance): Aqueous bromide salt solutions are typically of low flammability and low volatility. However, hazard profiles can vary with concentration and additives (e.g., preservatives, ISA components). Always consult the SDS supplied with the lot.
  • Incompatibilities (general):
    • Strong oxidizers can convert bromide to bromine or bromine-containing oxidized species.
    • Silver salts precipitate AgBr; avoid contact if preserving bromide content is necessary.
    • Strong acids in the presence of oxidants may liberate bromine vapors.
  • Personal protective equipment (good laboratory practice): Safety glasses with side shields, lab coat, and appropriate chemical‑resistant gloves. Use in a well‑ventilated area; avoid ingestion and contact with eyes/skin.
  • First‑aid (general):
    • Eye/skin contact: Rinse with water for several minutes; remove contaminated clothing. Seek medical attention if irritation persists.
    • Ingestion/inhalation: Rinse mouth, move to fresh air. Obtain medical advice based on SDS guidance.
  • Waste handling (general): Collect aqueous halide wastes separately if your facility requires. Do not discharge to drain unless permitted by local regulations. Neutral, non‑hazardous classification is not assumed—confirm by SDS.
Solvent Selection

These are aqueous solutions intended for potentiometric measurements; solvent selection in the chromatographic sense is generally not applicable.

Practical considerations for matrix compatibility (general guidance):

  • Polarity and medium: Water is the medium for bromide ISE measurements. Non‑aqueous or mixed solvents can alter membrane response and activity coefficients; use only if your method is validated for such matrices.
  • Sample types: Environmental waters, process waters, and extracts can be measured directly or after dilution into an aqueous matrix. Use an appropriate ionic strength adjuster (ISA) when required by the method to standardize ionic strength across standards and samples.
  • Temperature: Maintain constant temperature between standards and samples for consistent Nernstian slope.
  • Alternative media: For high‑ionic strength or viscous samples (e.g., brines), consider standard additions rather than external calibration to mitigate matrix effects (literature practice).

Comparison (general):

  • Aqueous standards vs. mixed‑solvent standards: Aqueous standards provide predictable activity and are compatible with most bromide ISE membranes; mixed‑solvent systems can lead to membrane swelling or altered selectivity and are generally avoided unless specified by the electrode manufacturer.
Storage & Reconstitution
  • Storage conditions (from Product Data): Store at room temperature. Shipment under normal conditions.
  • Stability/shelf life: Not specified for this item; refer to CoA/Spec Sheet.
  • Reconstitution: Not applicable if supplied ready‑to‑use. If supplied as a concentrate or solid, follow the CoA/Spec Sheet for dilution and solvent requirements (not specified for this item).
  • Handling to maintain integrity (general):
    • Keep containers tightly closed to prevent evaporation and concentration drift.
    • Avoid cross‑contamination: dispense with clean, dedicated pipettes; never return used aliquots to the stock bottle.
    • Minimize headspace exposure if long‑term storage is expected; consider aliquoting.
    • Protect from strong light and oxidants that could alter bromide content.
  • Freeze–thaw: Typically unnecessary and not recommended for aqueous standards; store at room temperature as specified.
  • Labeling and traceability: Record opening date and lot number. For regulated environments, maintain calibration logs and verification against an independent standard if required.
Structure & Identity

This product comprises aqueous solutions formulated for use with bromide ion-selective electrodes (ISEs). As a mixture designed for analytical calibration/measurement, it does not have a single molecular structure.

  • Item-specific identifiers:
    • CAS: Not specified for this item; refer to CoA/Spec Sheet.
    • InChIKey / SMILES: Not applicable to mixtures; not specified for this item.
    • Molecular formula: Not applicable to mixtures; not specified for this item.
    • Molecular weight: Not applicable to mixtures; not specified for this item.
  • Structural features (general/literature context):
    • Bromide ion is the monovalent anion Br−, typically present in aqueous solution counterbalanced by alkali cations (e.g., Na+, K+) or as part of complex matrices; exact counter‑ions in this product are not specified.
    • For ISE applications, solution types commonly include calibration standards at defined bromide activities, ionic strength adjusters (ISA), and/or reference/filling solutions (literature, general practice). The exact solution types and concentrations for this SKU are not specified; consult the CoA/Spec Sheet.
  • 2D description (general):
    • The bromide ion is a spherical anion with full octet; in water it is strongly solvated by a hydrogen‑bond network. Any accompanying cations (if present) are likewise hydrated. No stereochemistry applies.

Notes:

  • This product is intended for analytical electrochemistry; identity is defined by function (bromide activity control) rather than discrete molecular structure.
Synthetic Utility

This product is not intended as a synthetic reagent. It is designed for ion‑selective electrode calibration/measurement. For synthetic chemistry requiring bromide sources (e.g., NaBr, KBr, TBABr), select the appropriate solid or concentrated reagent grade and consult the corresponding product documentation.

Analytical cross‑over (general):

  • When monitoring bromination reactions or halide exchange processes, ISE solutions and electrodes can provide rapid, in‑process measurement of bromide concentration in aqueous phases, aiding reaction control without the need for full chromatographic workups.
Target Specificity

Not applicable. This product is not an antibody or affinity reagent. No antigen/epitope specificity, clone, isotype, or species reactivity applies.

Frequently Asked Questions

How should this product be stored?
Store at room temperature.
How is this product shipped?
This product ships under standard ambient conditions. No temperature-controlled packaging is required.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.