FastSYBR Mixture - 5 ml

Cat. No.: F665884
AVAILABLE TO ORDER
GRADE & PURITY 5 ml
Storage
Store at -20°C
Shipped In
Ice chest + Ice pads
 ·  off list, applied to all prices below.
Size
Status
Price
Qty
5ml
F665884-5ml
1-2 wks(?)
Item is derived from our semi-finished stock and is processed in 1-2 weeks.
$97.90
Enter a quantity for the sizes you want to add.
🧪

Why this grade

5 ml for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Store at -20°C Ships Ice chest + Ice pads Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

Overview

FastSYBR Mixture is a premixed system specifically designed for real-time fluorescence quantitative PCR using the dye method (SYBR Green I), with a concentration of 2 x, containing Fast Taq DNA Polymerase, PCR Buffer, dNTPs, SYBR Green I fluorescent dye, and Mg2+. The operation is simple and convenient. Mainly used for detecting genomic DNA target sequences and cDNA target sequences after RNA reverse transcription. The fluorescent dye SYBR Green I contained in this product can bind to all double stranded DNA, making it suitable for detecting different target sequences without the need for synthesizing specific labeled probes. The Fast Taq DNA Polymerase contained in this product can effectively reduce non-specific amplification caused by non-specific binding of primers and templates or primer dimers at room temperature. Enzyme activation only requires incubation at 95 ℃ for 20 seconds. The entire PCR reaction process can save about 40 minutes compared to ordinary reactions, greatly reducing the reaction time of PCR. The unique combination of PCR buffer system and hot start enzyme effectively inhibits the production of non-specific products and significantly improves the amplification efficiency of PCR. This product has a wide range of applications and is suitable for both regular and rapid quantitative PCR programs. ROX dye is used to correct the fluorescence signal error between wells in quantitative PCR instruments, and is generally used in Real Time PCR amplification instruments from companies such as ABI and Stratagene. The excitation optical systems of different instruments vary, so the concentration of ROX dye must be matched with the corresponding fluorescence quantitative PCR instrument.
Instruments that do not require ROX calibration: Roche LightCycle 480, Roche LightCylinder 96, Bio rad iCylinder iQ, iQ5, CFX96, etc.
Instruments that require Low ROX calibration: ABI Prism7500/7500 Fast, QuantStudio ® 3 System, QuantStudio ® 5 System, QuantStudio ® 6 Flex System, QuantStudio ® 7 Flex System, ViiA 7 System, Stratagene Mx3000/Mx3005P, Corbett Rotor Gene 3000, etc.
Instruments that require High ROX calibration include ABI Prism7000/7300/7700/7900, Eppendorf, ABI Step One/Step One Plus, etc.

Component F665884 5 ml
2×FastSYBR Mixture 5×1 ml
50×Low ROX /
50×High ROX /
ddH2O 5×1 ml

Matters needing attention
1. Before use, please gently mix upside down to avoid foaming, and use after briefly centrifugation.
2. This product contains the fluorescent dye SYBR Green I. When storing this product or preparing PCR reaction solution, strong light exposure should be avoided.
3. Avoid repeated freezing and thawing of this product, as repeated freezing and thawing may cause a decrease in product performance. This product can be stored for a long time at -20 ℃, away from light. If frequent use is required in the short term, it can be stored at 2-8 ℃.
4. This product cannot be used for probe based fluorescence quantitative PCR.
Usage
The following are examples of conventional PCR reaction systems and reaction conditions. In practical operation, corresponding improvements and optimizations should be made based on different templates, primer structures, and target fragment sizes.
1. PCR reaction system

Reagent 50 μL Reaction system Final concentration
2×FastSYBR Mixture 25 μL 1 ×
Forward Primer,10 µM 1 μL 0.2 μM ¹⁾
Reverse Primer,10 µM 1 μL 0.2 μM ¹⁾
Template DNA 2 μl ²⁾ /
50×Low ROX or High ROX
(optional)³⁾
1 μL 1 ×
ddH2O up to 50 μl /

Attention:
1) Typically, the primer concentration is 0.2 μ M can achieve good results, ranging from 0.1 to 1.0 μ M serves as a reference for setting the range. In the case of low amplification efficiency, the concentration of primers can be increased; When non-specific reactions occur, the primer concentration can be reduced to optimize the reaction system.
2) The amount of DNA template is usually based on 10-100 ng genomic DNA or 1-10 ng cDNA as a reference. Due to the different copy numbers of target genes contained in templates of different species, gradient dilution can be applied to the template to determine the optimal template usage.
3) The excitation optical systems of different instruments vary, and 50 x Low ROX or 50 x High ROX can be added according to the instrument used for fluorescence quantification
2. PCR reaction conditions

Step Temperature Time /
Pre denaturation 95℃ 20 s ¹⁾ /
Denaturation 95℃ 3 s 35-40 cycles
Annealing/Extension ² ⁾ 60℃ 30 s 35-40 cycles
Analysis of Fusion Curve ³ ⁾ / / /
/ 95℃ 15 s /
/ 60℃ 1 min /
/ 95℃ 15 s /
/ 60℃ 15 s /

Attention:
1) The enzyme used in this product must be activated under pre denaturation conditions of 95 ℃ and 20 seconds. Under these conditions, most templates can perform well in de chaining. For templates with high GC content and complex secondary structures, the pre denaturation time can be extended to 1 minute to fully unwind the starting template. If the high-temperature treatment time is too long, it will affect the enzyme activity. The optimal pre denaturation time can be determined based on the template situation.
2) It is recommended to use a two-step PCR reaction program, and the annealing temperature should be set at 60-64 ℃ as a reference range. When non-specific reactions occur, the annealing temperature can be increased. If good experimental results cannot be obtained due to the use of primers with lower Tm values, a three-step PCR amplification method can be attempted. The annealing temperature should be set within the range of 56 ℃ -64 ℃ as a reference.
3) Please set the fusion curve analysis according to the recommended program of the fluorescence quantitative PCR instrument used. This program is based on the ABI 7500 fluorescence quantitative PCR instrument as a reference setting.

Specifications

Specifications & Purity
5 ml
Storage
Store at -20°C
Shipped In
Ice chest + Ice pads
This product requires cold chain shipping. Ground and other economy services are not available.

Documentation

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Certificates(CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Documents & Articles
Solution Calculators
Reviews

Customer Reviews

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.