GRADE & PURITYMoligand™?Moligand™ — Aladdin's line of ligands and bioactive small molecules. Use for receptor, pathway, and binding studies needing defined small-molecule tools.≥99%
iCRT-5 is a β-catenin-regulated transcription (CRT) inhibitor. iCRT-5 can block Wnt/β-catenin reporter activity and down regulate β-catenin expression
Specifications
Specifications & Purity
Moligand™, ≥99%
Biochemical and Physiological Mechanisms
iCRT-5 is a β-catenin-regulated transcription (CRT) inhibitor. iCRT-5 can block Wnt/β-catenin reporter activity and down regulate β-catenin expression. iCRT-5 can be used for the research of multiple myeloma.
Storage
Store at -20°C
Shipped In
Ice chest + Ice pads
This product requires cold chain shipping. Ground and other economy services are not available.
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
Reviews
Customer Reviews
Application Protocols
Item-specific facts (from Product Data)
Tested applications, assay formats, or recommended dilutions: Not specified for this item; refer to CoA/Spec Sheet.
General protocol guidance for small-molecule probes (non-item-specific)
Stock solution: Dissolve in anhydrous DMSO to 10–50 mM. Vortex and, if needed, sonicate gently. Filter through 0.22 µm PTFE for sterile applications.
Working solutions: Prepare fresh daily. Add stock to prewarmed media/buffer with vigorous mixing to achieve target concentration while keeping DMSO ≤0.1–0.5% v/v.
Concentration–response: Use serial 1:3 or 1:2 dilutions over a range spanning anticipated potency (e.g., 0.01–30 µM). Include vehicle control and, where possible, a positive control compound.
Incubation: 1–24 h for acute responses; longer exposures may require media changes and redosing to maintain concentration.
Data quality: Monitor precipitation/turbidity. Where fluorescence/absorbance readouts are used, check for intrinsic compound interference and correct using matched blanks.
Storage of solutions: Aliquot DMSO stocks to avoid freeze–thaw; store at −20 °C in amber vials. Discard if discoloration/precipitation persists after warming or if LC–MS indicates degradation.
Note
Optimize protocol parameters empirically for your cell line/assay. In absence of item-specific recommendations, small-scale pilot experiments are strongly advised.
Biological Roles
Item-specific facts (from Product Data)
Specific biological target(s), pathway, or MoA: Not specified for this item; refer to CoA/Spec Sheet and primary literature.
Research use note: For research use only.
General context for small-molecule research probes (non-item-specific)
Role in research: Small molecules like iCRT-5 are commonly used to perturb cellular pathways to study signaling, transcriptional regulation, or protein–protein interactions. They function as chemical tools to generate testable hypotheses about pathway dependencies.
Use in assay types: Applied in cell-based phenotypic assays, reporter gene assays, biochemical binding or activity measurements, and target deconvolution workflows.
Off-target considerations: Many discovery-stage probes can engage secondary targets at higher concentrations. Employ orthogonal assays and inactive analogs where available, and confirm results with genetic controls.
Concentration ranges: Exploratory studies often evaluate 0.01–30 µM concentration windows, adjusting for solubility and cytotoxicity of vehicle. Actual potency values for this item are not provided here.
Kinetic and stability factors: Time-dependent effects may reflect slow binding or intracellular accumulation; verify exposure times and intracellular free concentration using appropriate controls.
Documentation and reproducibility
Record lot numbers, stock concentration, vehicle percentage, exposure time, and cell passage. Validate activity with fresh stocks and replicate across days to confirm robustness.
Buffer Applications
Not typically applicable
iCRT-5 is a small-molecule probe rather than a buffering agent. It does not define a pH range or buffering capacity for laboratory preparations.
Practical notes for use in buffered systems (general)
Vehicle dilution: Prepare a DMSO (or other suitable solvent) stock and dilute into the desired assay buffer (e.g., PBS, HBSS, culture media) to a low final vehicle percentage (commonly ≤0.1–0.5% v/v) to avoid perturbing osmolarity and pH.
Precipitation control: Add the stock to buffer slowly with mixing. If precipitation occurs, consider adding a small amount of co-solvent, adjusting temperature, or using solubilizers (e.g., cyclodextrins), ensuring compatibility with your assay.
Adsorption and loss: For very hydrophobic compounds, adsorption to glass or plastics can reduce free concentration; use low-bind plastics or silanized glassware and verify free drug via analytical sampling if critical.
Green Alternatives
Context
Because iCRT-5 is a defined research probe rather than a process solvent or commodity reagent, the concept of “green alternatives” focuses on how you handle and deliver the compound (solvents, waste minimization) rather than substituting the active itself.
Greener handling strategies (general)
Solvent minimization: Use the highest feasible stock concentration to reduce DMSO volume in assays, provided solubility and stability allow.
Alternative vehicles: Where compatible, consider more benign co-solvents (e.g., aqueous buffers with cyclodextrins) to decrease DMSO/DMF reliance; validate assay performance and compound recovery.
Microscales: Employ miniaturized assay formats (96/384/1536-well) to reduce chemical use and waste.
Closed handling: Use sealed, amber microvials to limit volatilization and light exposure, reducing the need for repeat preparations.
Comparison (general; not item-specific)
Vehicle options vs impacts:
DMSO: excellent solvency; moderate toxicity; miscible with water; widely accepted for bioassays.
Ethanol: lower toxicity; may affect membrane properties/enzymes; volatility can change dosing over time.
Aqueous + solubilizers (e.g., HP-β-CD): greener profile; can alter apparent potency via binding; requires calibration.
Waste and EHS
Segregate halogenated vs non-halogenated organic waste where applicable. Use compatible sorbents and secondary containment to prevent spills.
Note
There is no established “green substitute” for the probe itself without changing experimental outcomes; optimize formulation and assay design instead.
Pharmaceutical Uses
Scope and limitations
This product is supplied strictly for research use only. No pharmacopeial status, GMP qualification, or clinical/formulation claims are provided for this item.
General information (non-item-specific)
Small molecules used as pathway probes in discovery research are occasionally explored in pre-formulation studies to assess solubility, stability, and delivery feasibility. Such work is distinct from any approved pharmaceutical use and requires extensive additional characterization (purity, polymorph, stability, impurity profile) under regulated standards.
Excipients/vehicles: For in vitro or exploratory in vivo research (non-clinical), common vehicles include DMSO, PEG-400, aqueous buffers with surfactants, or cyclodextrin complexes. Selection is driven by compound solubility and stability and must be validated case-by-case.
Compliance note
This material is not intended for human or veterinary use. It is not manufactured under GMP, and there are no stated pharmacopeial monographs or compendial tests associated with this SKU.
If you require a grade suitable for regulated development activities, contact us to discuss custom manufacturing, additional QC (e.g., residual solvent limits, elemental impurities), and documentation support.
Physical Properties
Item-specific facts (from Product Data)
Physical appearance: Not specified for this item; refer to CoA/Spec Sheet.
Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
Not specified for this item; refer to CoA/Spec Sheet (do not treat as specifications)
Melting point (MP)
Boiling point (BP)
Density
Refractive index
LogP/logD
pKa
Aqueous solubility
UV/Vis absorption or cutoff
Literature/general guidance for small-molecule screening compounds (non-specific)
Solubility: Many pathway-probe small molecules are sparingly water-soluble and are routinely prepared as concentrated DMSO stock solutions (e.g., 10–50 mM), then diluted into assay buffers to ≤0.1–0.5% v/v DMSO final to limit vehicle effects. Actual solubility must be confirmed experimentally for this item.
Solid-state form: Compounds may be provided as free base/neutral form or as a salt/hydrate; this strongly affects MP, hygroscopicity, and dissolution. Confirm on the CoA.
Spectral characterization: Routine identity confirmation in research settings uses LC–MS (single- or high-resolution), 1H/13C NMR, and HPLC purity profiles. Where UV characterization is required (e.g., for HPLC diode array), determine λmax empirically.
Stability factors to consider: sensitivity to light, air (oxidation), moisture (hydrolysis), and temperature. Conduct small-scale stability checks under intended assay conditions.
Note: In absence of item-specific metrics, do not assume typical values from literature; verify lot-specific data on the CoA.
Quality & Grades
Item-specific facts (from Product Data)
Grade/Purity designation: Moligand™.
What Moligand™ indicates (general description)
Moligand™ is used by Aladdin Scientific to denote small-molecule ligands/probes curated for research and discovery applications. While exact purity thresholds, residual solvent limits, and identity criteria are batch-specific, Moligand™-grade items are intended for biological screening, target-validation studies, and chemical-biology workflows.
Practical implications
Documentation: For each lot, consult the CoA for purity method (e.g., HPLC/UPLC area%), assay value, and identity confirmation (LC–MS, NMR). Where stabilizers or salt forms are used, these will be explicitly listed on the CoA/SDS.
UV suitability: If using in optical assays (fluorescence/absorbance), request or determine UV/Vis profiles to avoid interference.
Inorganic/metal content: Not specified for this item; refer to CoA/Spec Sheet. If using in metal-sensitive assays, consider additional purification or ICP screening.
Water content: Not specified for this item; refer to CoA/Spec Sheet. For hygroscopic materials, Karl Fischer data may be provided lot-wise.
Recommendations
For screening libraries or SAR campaigns, standardize purity criteria across lots and document analytical methods. If you require additional quality controls (e.g., enantiomeric excess, residual solvent limits), contact us prior to ordering to arrange custom QC.
Reaction & Applications
Applicability to this compound type
This product is supplied as a small-molecule research probe (Moligand™). It is not primarily positioned as a synthetic reagent or catalyst.
Not typical applications (and why)
Named reactions, stoichiometric reagents, or catalysts: Not typically applicable without a defined functional group profile. This item is intended for biological screening and chemical-biology studies rather than for effecting chemical transformations.
Research applications (general, non-item-specific)
Target/pathway interrogation in cell or biochemical assays, high-content screening, and mechanistic studies where small molecules modulate protein–protein interactions or signaling nodes. Exact target specificity for this SKU is not provided here; consult related literature by compound name and confirm with CoA to avoid misassignment.
SAR and profiling: Researchers may compare iCRT-5 with analogs to evaluate structure–activity trends. Ensure identical vehicle and exposure conditions across assays to enable fair comparisons.
Practical tips
Prepare fresh working solutions immediately before use to reduce degradation risk.
Validate concentration–response with at least 8–12 points and duplicates; record vehicle-only controls to quantify DMSO effects.
For biochemical assays, verify compound integrity post-incubation by LC–MS to rule out rapid hydrolysis/oxidation as a confounder.
Reaction Conditions
Not applicable for this product’s intended use
iCRT-5 is a research probe, not a reagent for promoting chemical reactions. Therefore, standard entries for catalysts, equivalents, temperatures, or solvent systems in synthetic reactions do not apply.
Practical handling conditions (general)
Solution preparation: Prepare concentrated stock solutions (commonly 10–50 mM) in DMSO under ambient conditions, protecting from light if indicated by the CoA/SDS.
Assay conditions: Typical incubation temperatures are 20–37 °C depending on the biological assay. Keep final vehicle concentration low and constant across controls and treatments.
Stability checks: Where activity loss is suspected, confirm compound integrity after incubation via LC–MS. Avoid extended exposure to elevated temperatures unless stability has been established.
Note
Do not extrapolate chemical reaction “conditions” to biological assays. Follow protocol-specific conditions validated for your assay platform.
Safety & Handling
Item-specific facts (from Product Data)
GHS classification, signal word, pictograms, and H-statements: Not specified for this item; refer to SDS.
Storage condition: Store at −20 °C.
Shipped in: Ice chest + ice pads (protects from heat during transit).
Research use note: For research use only.
General laboratory safety guidance (not item-specific; defer to SDS)
Personal protective equipment: lab coat, safety glasses, and appropriate chemical-resistant gloves (e.g., nitrile). Avoid inhalation of dust or vapors and contact with skin/eyes.
Engineering controls: handle powders/solutions in a fume hood; use local exhaust when weighing or dissolving.
Incompatibilities to consider: strong oxidizers, strong acids/bases, and reactive reducing agents; actual incompatibilities depend on the compound’s functional groups—consult SDS once structural details are confirmed.
Hygiene: wash thoroughly after handling; avoid ingestion and aerosol generation. Keep containers tightly closed to prevent moisture uptake and contamination.
First aid overview: in case of eye/skin contact, rinse with water for 15 minutes and remove contaminated clothing; if inhaled, move to fresh air; if ingested, rinse mouth and seek medical attention. Always follow the SDS for authoritative instructions.
Waste disposal: collect in an appropriate organic waste stream compatible with the solvent matrix (e.g., DMSO/organic). Dispose according to institutional and local regulations.
Special risks
Some discovery compounds may be light- and/or air-sensitive. Minimize exposure, use amber vials, and purge headspace with inert gas if recommended by the CoA/SDS.
Solvent Selection
Item-specific facts (from Product Data)
Solubility and solvent preferences: Not specified for this item; refer to CoA/Spec Sheet.
General guidance for small-molecule probes (non-item-specific)
Stock preparation: DMSO is the default solvent for many hydrophobic discovery compounds. Start by testing dissolution at 10 mM, warming gently (≤37 °C) and vortexing/sonication. If insoluble at 10 mM, step down concentration or consider co-solvents.
Co-solvent systems: When aqueous delivery is required, dissolve in DMSO first, then dilute into buffer while vortexing to a final DMSO content typically ≤0.1–0.5% v/v to minimize vehicle effects. Add nonionic surfactants (e.g., 0.01–0.05% Tween-20 or Pluronic F-68) if precipitation occurs—verify assay compatibility.
Alternative solvents: DMF or ethanol can help where DMSO is inadequate, but assess cytotoxicity/assay interference. For chemical experiments, dry acetonitrile or ethyl acetate may be options depending on functional groups (unknown here—confirm compatibility once structure is available).
pH effects: If the compound contains ionizable groups (unknown here), controlled pH can dramatically alter solubility; prepare buffered systems near the compound’s pKa. In absence of pKa data, empirically screen pH 6–8 for bioassays.
Practical tips
Filter sterilization: If needed for cell-based work, pre-dissolve in solvent, then sterile-filter (0.22 µm PTFE) to avoid adsorption losses on hydrophilic membranes.
Adsorption: Highly lipophilic molecules can adsorb to plastic; use low-bind PP tubes or glass vials.
Storage & Reconstitution
Item-specific facts (from Product Data)
Storage conditions: Store at −20 °C.
Shipping: Ice chest + ice pads.
Appearance: Not specified for this item; refer to CoA/Spec Sheet.
General storage guidance (non-item-specific)
Container: Keep in tightly closed, chemically compatible, amber vials to protect from light. Purge with inert gas if the compound is air/moisture sensitive (check CoA/SDS).
Avoid freeze–thaw: Sub-aliquot solid (if feasible) or prepare multiple small-volume DMSO stock aliquots to prevent repeated thaw cycles.
Stability: Many small molecules are stable for 12–24 months at −20 °C when protected from light and moisture, but actual shelf life is lot-specific; consult the CoA for expiry/retest date.
Reconstitution (general)
Solvent: DMSO is commonly suitable for initial dissolution. If DMSO is unsuitable, evaluate DMF or ethanol; confirm compatibility with downstream assays.
Procedure: Allow vial to equilibrate to room temperature in a desiccated environment before opening to minimize moisture condensation. Weigh quickly, cap promptly, and dissolve with gentle warming/sonication if required.
Working solution handling: After diluting into aqueous buffers/media, use promptly. Some compounds may precipitate upon cooling or prolonged standing; prepare fresh as needed.
Documentation
Record lot number, preparation date, stock concentration, solvent, and storage conditions. Refer to the CoA/SDS for any item-specific cautions (light sensitivity, hygroscopicity, or recommended maximum concentration).
Structure & Identity
Item-specific facts (from Product Data)
Product name: iCRT-5 (SKU: I647133)
CAS: 18623-44-4
Grade/Purity: Moligand™
Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
SMILES: Not specified for this item; refer to CoA/Spec Sheet.
InChIKey: Not specified for this item; refer to CoA/Spec Sheet.
Literature/general notes
iCRT-5 is commonly referenced in the literature as a small-molecule research tool used in pathway interrogation studies. However, exact structural identifiers vary by supplier reports. To avoid ambiguity, please consult the product CoA/SDS for definitive identifiers for this catalog item.
Structural discussion (general)
Without a provided structure, detailed functional-group, ring-system, or stereochemical analysis cannot be confirmed for this specific item. If a structure is provided on the CoA/Spec Sheet, typical points to examine include: presence/absence of heteroatoms (N, O, S), aromatic substituents, potential salt forms, and chiral centers. These features influence solubility (e.g., H-bond donors/acceptors), stability (e.g., hydrolysis/oxidation), and assay compatibility.
Documentation guidance
For exact identity confirmation in regulated or data-critical studies, request and retain: CoA (lot-specific), SDS, and, when available, NMR/LC-MS traces or HRMS data. Where ambiguity exists in public literature, supplier-issued identifiers (SMILES/InChIKey) should be treated as authoritative for this SKU.
Synthetic Utility
Not typically applicable
iCRT-5 (Moligand™) is a designated small-molecule research probe and is not offered as a synthetic reagent, building block, or catalyst. Without item-specific structural data, it is inappropriate to infer functional-group reactivity or named-reaction roles.
General considerations (if structure becomes available)
If your workflow involves derivatization (e.g., biotinylation, photoaffinity tagging), consult the structure to identify modifiable positions that preserve activity. Evaluate SAR to ensure the tag or linker does not abolish binding.
For immobilization or pull-down experiments, introduce linkers via positions known to tolerate substitution and confirm target engagement versus the parent compound.
Documentation
When modifying the scaffold, retain full analytical characterization (LC–MS, HRMS, NMR, HPLC purity) and, where relevant, measure stereochemical integrity (chiral HPLC), as activity can be enantioselective for many ligands.
Target Specificity
Item-specific facts (from Product Data)
Specific target(s), binding site, or selectivity profile: Not specified for this item; refer to CoA/Spec Sheet and primary literature.
General guidance
When using small-molecule probes, confirm target engagement using orthogonal methods (e.g., reporter assays plus biochemical binding, or CETSA/DSF). Include negative controls and, if available, structurally related inactive analogs.
Determine on-target versus off-target effects by varying exposure time and concentration and by employing genetic perturbations (knockdown/knockout/overexpression) as complementary evidence.
Documentation
Cite exact lot numbers and provide full handling details in publications to ensure reproducibility. Where available, include binding constants or IC50/EC50 values derived under your conditions rather than relying solely on literature.
Need help choosing the grade?
Our grade selection guide covers purity, stabilizer status, and application suitability for all variants in our catalog.
We use cookies to ensure the website functions properly and, where permitted, to improve your experience. You can manage your preferences at any time in Settings. Learn more in our Cookie Policy.
Shall we send you a message when we have discounts available?
Remind me later
Thank you! Please check your email inbox to confirm.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.