Imatinib-d4 - ≥99% , CAS No.1134803-16-9

CAS: 1134803-16-9 Cat. No.: I649056 Formula: C29H27D4N7O Molecular Weight: 497.63
AVAILABLE TO ORDER
GRADE & PURITY ≥99%
Storage
Store at -20°C
Shipped In
Ice chest + Ice pads
★
Size
USA
Germany (EU)*
Price
Qty
1mg
I649056-1mg
Made to order · 8–12 wks
$500.90
5mg
I649056-5mg
Made to order · 8–12 wks
$1,100.90
Enter a quantity for the sizes you want to add.

Overview

Imatinib-d 4 is a deuterium labeled Imatinib (STI571). Imatinib is an orally bioavailable tyrosine kinases inhibitor that selectively inhibits BCR/ABL, v-Abl, PDGFR and c-kit kinase activity.

Form:Solid

Specifications

Specifications & Purity
≥99%
Biochemical and Physiological Mechanisms
Imatinib-d 4 is a deuterium labeled Imatinib (STI571). Imatinib is an orally bioavailable tyrosine kinases inhibitor that selectively inhibits BCR/ABL, v-Abl, PDGFR and c-kit kinase activity.
Storage
Store at -20°C
Shipped In
Ice chest + Ice pads
This product requires cold chain shipping. Ground and other economy services are not available.
Action Type
INHIBITOR
Purity
≥99%
Names and Identifiers
Molecular Weight
497.63

Advanced Data

Certificates (CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Solution Calculators
Reviews

Customer Reviews

Application Protocols

Below are generalized protocols for using Imatinib‑d4 as an internal standard in LC–MS/MS. Adjust to your matrix, instrumentation, and regulatory context. These are literature-style guidelines; no item-specific performance claims are made.

  • Stock preparation

    • Weigh an accurate amount using an analytical balance. Use the item-specific MW from the CoA to prepare a 1–10 mg/mL stock in DMSO, MeOH, or MeCN. Store aliquots at −20°C.
  • Working solution

    • Prepare an intermediate solution (e.g., 100–1000 ng/mL in MeCN:water 50:50 with 0.1% formic acid). Keep on ice or in an autosampler at 4–10°C during use.
  • Sample spiking (example workflow)

    • Add internal standard to blank matrix to achieve a fixed concentration across all calibrators, QCs, and unknowns (e.g., 50 ng/mL). Vortex to mix.
    • Precipitate proteins with 3–4 volumes of cold MeCN or MeOH, vortex, centrifuge, and transfer supernatant to LC–MS vials. Alternatively, use mixed-mode cation-exchange SPE for cleaner extracts.
  • LC–MS/MS acquisition

    • Use ESI+; set MRM for imatinib (d0) and imatinib‑d4 (d4) transitions with distinct product ions. Optimize collision energy and declustering potentials.
  • Data analysis

    • Calculate analyte/internal standard peak area ratios. Fit calibration with appropriate weighting (e.g., 1/x or 1/x²). Evaluate accuracy, precision, and matrix effects per validation guidelines.

Ensure all preparations align with the CoA/Spec Sheet and institutional SOPs. Research use only.

Biological Roles

No biological roles are assigned to this product as sold; it is a research-use, isotopically labeled small molecule.

  • General (literature context)

    • Imatinib is a well-known small molecule that engages specific protein kinases in biochemical systems; however, Imatinib‑d4 is used as an analytical surrogate and does not confer biological function in typical workflows.
    • Deuteration does not materially alter binding properties in most cases, but this product is not intended for biological modulation; it serves as a mass-differentiated tracer for quantitation.
  • Research utility

    • Facilitates accurate determination of imatinib concentrations in complex biological matrices during method development, PK-like research studies in preclinical systems, or stability testing of formulations, without implying any therapeutic or clinical application.

Note: No clinical/medical claims are made. For all bioanalytical applications, this product is for research use only (per Product Data).

Buffer Applications

This compound is not a buffering agent and is not typically used to prepare biological or analytical buffers.

  • Practical note
    • When formulating mobile phases for LC–MS assays employing Imatinib‑d4 as an internal standard, common buffers are volatile systems such as water with 0.1% formic acid, or ammonium formate/acetate (1–20 mM) in water–acetonitrile or water–methanol. Selection depends on the chromatographic method and detector requirements.

For pH control or buffering capacity, use appropriate buffer systems (e.g., ammonium acetate/formate). Imatinib‑d4 itself does not provide a defined buffering range.

Green Alternatives

For Imatinib‑d4 itself, “green alternatives” concern the choice of solvents and workflows in analytical use rather than replacing the compound.

  • Solvent considerations (comparative, general)

| Aspect | MeCN | MeOH | EtOH | 2‑PrOH | |---|---|---|---|---| | Greenness | Petro-based; moderate toxicity | Renewable routes; toxicologically manageable | Widely accepted; lower toxicity | Higher VOC load | | LC–MS performance | Excellent volatility, peak shape | Good; can broaden peaks | Acceptable; higher viscosity | Acceptable; higher viscosity | | Typical use | Mobile phase/working soln | Working soln/precipitation | Precipitation/extractions | Protein precipitation |

  • Recommendations
    • Prefer MeOH or ethanol where chromatographic performance permits; retain MeCN when necessary for resolution/robustness.
    • Use volatile, low-toxicity acid modifiers (formic or acetic acid) rather than nonvolatile acids.
    • Minimize solvent volumes via microsampling and high-sensitivity MS methods; adopt 96‑well formats to reduce waste.
    • Implement solvent recycling where feasible for large-volume mobile phases.

Trade-offs: While greener alcohols reduce hazard, they may compromise peak shape or ionization for basic heteroaromatics; method optimization is required to avoid loss of sensitivity.

Pharmaceutical Uses

Imatinib‑d4 is not used as a therapeutic agent or excipient. In pharmaceutical research and quality environments, its role is analytical.

  • Typical roles in pharma R&D and QC (research context only)

    • Internal standard for LC–MS/MS quantitation of imatinib in preclinical matrices, in-process samples, or stability studies of development formulations.
    • Reference material for method transfer, instrument qualification checks, and calibration verification where an isotopically labeled analog of the analyte is required.
  • Standards and compliance considerations

    • When used in GMP-adjacent contexts, ensure traceability to a CoA with defined purity, isotopic enrichment, and uncertainty. Establish suitability through method validation parameters (selectivity, accuracy, precision, robustness) per ICH/USP analytical guidelines.
  • Formulation notes

    • Not an excipient; does not serve functional roles such as preservative, stabilizer, or solubilizer in drug products.

All uses are for laboratory research and analytical development only. No clinical or therapeutic claims are made.

Physical Properties

Item-specific values are not provided in the Product Data. The following guidance distinguishes between unspecified item data and general literature information on imatinib analogs.

  • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
  • Melting point, boiling point, density, refractive index: Not specified for this item; refer to CoA/Spec Sheet.
  • Solubility (general, literature for imatinib analogs)
    • Good solubility in polar aprotic organic solvents such as DMSO and DMF (typical for tertiary amine–containing, heteroaromatic drug-like molecules).
    • Limited aqueous solubility at neutral pH; solubility increases in acidic aqueous media due to protonation of the tertiary amine(s) (literature behavior for imatinib free base).
  • pKa/logP (general, literature)
    • Imatinib possesses basic piperazine nitrogens with pKa values in the basic range; protonation drives water solubility in acidic media (literature). Reported logP for the free base is in the moderate lipophilicity range; deuteration (d4) does not materially change partitioning within experimental error.
  • Hygroscopicity/peroxide formation: Not typically peroxide-forming; moderate hygroscopicity is possible for tertiary amine salts/solids; confirm with CoA.

Critical note: For quantitative analytical work (e.g., internal standards), rely on the item-specific CoA for exact MW (reflecting d4 labeling), water content, and purity. Where present, those supersede any literature approximations.

Quality & Grades
  • Item-specific grade/purity: Not specified for this item; refer to CoA/Spec Sheet.

  • Interpreting quality for isotopically labeled small molecules (general guidance)

    • Chemical purity (HPLC/UPLC area%): Determines background interferences. For LC–MS internal standards, >95% is commonly selected, but rely on item CoA.
    • Isotopic enrichment and pattern: Critical for quantitative MS. The CoA should state average deuterium incorporation (e.g., % d4) and distributions (d0–d4). Higher enrichment reduces isotopic overlap with the analyte.
    • Residual solvents, water content, counterion identity (if salt form): Affect stability and solution preparation; verify on CoA.
    • Low-level impurities: Deuterium–hydrogen exchangeable sites can lead to back-exchange; labeling at non-exchangeable positions is preferred for robust quantitation. Confirm with supplier documentation.
  • Analytical suitability

    • If described as “LC–MS grade” or “quantitation standard” (not specified here), this implies stringent control of inorganic/organic impurities and well-characterized isotopomer distribution.
  • What is specific to this item

    • Storage at −20°C and cold shipment are provided in Product Data, supporting integrity during transit and storage.
    • In absence of a stated grade, users should consult the CoA for purity, isotopic enrichment, and recommended analytical calibrations.
Reaction & Applications

As a stable-isotope–labeled analog, Imatinib‑d4 is primarily used as an internal standard rather than as a synthetic reagent. Key applications focus on quantitative mass spectrometry.

  • LC–MS/MS internal standard (bioanalytical method development)

    • Spike into samples (e.g., plasma, serum, cell lysate extracts, or formulation matrices) at a fixed concentration to correct for matrix effects, extraction recovery, and ionization variability.
    • Supports calibration curve construction, accuracy/precision assessment, and incurred sample reanalysis.
  • Metabolism and stability studies (research use)

    • Track parent analyte versus d4 standard to evaluate metabolic turnover, extractive losses, or adsorption to plastics.
  • Method validation parameters (typical, literature-driven)

    • Evaluate selectivity for MRM transitions that separate analyte (d0) from d4 internal standard by +4 Da; confirm absence of cross-talk at expected retention time.
    • Assess linearity, LLOQ, carryover, recovery, matrix factor, and stability (freeze–thaw, bench-top, autosampler) with the internal standard in place.
  • Practical tips

    • Prepare a single concentrated stock (e.g., in DMSO or MeOH) and generate fresh working solutions on the day of analysis to minimize adsorption and back-exchange.
    • Use low-bind polypropylene vials; glass may adsorb basic, heteroaromatic compounds in low-ionic-strength solutions.

Note: No manufacturer application notes are provided; the above expands on standard practices for labeled internal standards. All uses are for research only.

Reaction Conditions

This product is not mainly used as a reagent; therefore, classical “reaction conditions” are not typically applicable.

  • Analytical method conditions (general, literature-driven for LC–MS)

    • Chromatography: Reversed-phase C18; mobile phase A: water + 0.1% formic acid (or 5–20 mM ammonium formate/acetate); mobile phase B: acetonitrile or methanol. Gradient elution commonly employed.
    • Detection: ESI positive mode; monitor MRM transitions offset by +4 Da relative to imatinib (optimize collision energies empirically).
    • Sample prep: Protein precipitation with MeCN or MeOH; or SPE on mixed-mode cation exchange cartridges to enrich basic analytes. Evaluate matrix effects and ion suppression.
  • Stability considerations

    • Working solutions are commonly stable for hours to days at 4–10°C in autosampler vials; confirm empirically and per CoA. Protect from light and minimize adsorption by using low-bind plastics.

Note: The above are general guidelines for quantitative LC–MS assays of basic heteroaromatic small molecules and should be optimized for the specific instrument and matrix. No item-specific reaction conditions are claimed.

Safety & Handling
  • GHS/CLP information (item-specific)

    • Signal Word: Not specified for this item; refer to SDS.
    • Hazard Statements (H-codes): Not specified for this item; refer to SDS.
    • Pictograms and Classification: Not specified for this item; refer to SDS.
  • General hazards and precautions (good laboratory practice; defer to SDS)

    • Avoid inhalation of dust and contact with skin/eyes. Use in a chemical fume hood.
    • Wear appropriate PPE: lab coat, nitrile gloves, safety glasses; upgrade to splash goggles and double gloves for weighing and solution prep.
    • Prevent environmental release; collect waste in compliance with institutional and local regulations.
  • First-aid overview (general)

    • Skin/eye contact: Rinse with water for at least 15 minutes; remove contaminated clothing; seek medical attention as needed.
    • Inhalation: Move to fresh air; monitor for respiratory irritation; seek medical attention if symptoms persist.
    • Ingestion: Rinse mouth; do not induce vomiting; seek medical attention.
  • Handling notes for isotopically labeled standards

    • Minimize cross-contamination between labeled and unlabeled analytes to preserve quantitation fidelity.
    • Prepare stock solutions with calibrated balances and Class A glassware; document exact concentration using item-specific MW from the CoA.
  • Storage incompatibilities and stability

    • Store at −20°C (per Product Data). Protect from light and moisture. Avoid strong oxidizers and strong acids/bases during storage.

Always consult the product SDS for authoritative safety, toxicological, and regulatory information.

Solvent Selection

Imatinib‑d4 behaves similarly to the unlabeled parent with respect to solvent compatibility. Selection should balance solubility, stability, and MS cleanliness.

  • Primary solvents (analytical practice, literature)

    • DMSO: Excellent solubility for stock solutions (1–10 mg/mL typical); dilute into aqueous buffers immediately before use to minimize precipitation.
    • Methanol or acetonitrile (MeCN): Suitable for LC–MS mobile phases and working solutions; MeCN often preferred for sharper peaks and lower viscosity.
    • Water with acid modifier (0.1% formic acid): Enhances ionization and solubility of protonated species for ESI‑MS.
  • Miscibility profile (general)

    • DMSO, MeOH, and MeCN are fully miscible with water, enabling straightforward serial dilutions for calibration curves.
  • When to choose each

    • DMSO stocks: Highest stability/solubility; minimize final %DMSO (<1–2%) in bioanalytical assays to avoid matrix effects.
    • MeOH/MeCN working solutions: Cleaner backgrounds for LC–MS; facilitate rapid evaporation if needed for dry-down and reconstitution.
  • Comparison (practical)

    • MeOH gives stronger elution on reversed-phase at equal organic %, potentially broadening peaks; MeCN generally affords better peak shape for basic analytes with volatile acid modifiers.

Note: Confirm solvent and concentration limits with the item’s CoA/Spec Sheet, particularly if the product is supplied as a specific salt or with stabilizers (not specified here).

Storage & Reconstitution
  • Storage conditions (item-specific)

    • Store at −20°C (per Product Data).
    • Shipped in ice chest with ice pads to maintain cold chain during transit.
  • Handling and stability (general best practices)

    • Protect from light and moisture. Allow container to equilibrate to room temperature in a desiccator before opening to avoid condensation.
    • After first use, re-cap promptly and purge headspace with inert gas if possible to limit oxidation/hydrolysis.
  • Reconstitution guidance (general)

    • Prepare concentrated stock solutions in high-purity DMSO, methanol, or acetonitrile using the item-specific molecular weight from the CoA to calculate exact concentrations.
    • Filter (0.22 µm PTFE) if particulate is observed. Avoid aqueous reconstitution at neutral pH due to potential limited solubility of the free base; acidified aqueous media can improve solubility.
    • Aliquot stocks to single-use vials to minimize freeze–thaw; store aliquots at −20°C. Record preparation date and solvent.
  • Freeze–thaw guidance

    • Limit freeze–thaw cycles. If repeated access is needed, maintain a refrigerated (4–10°C) working solution for the analytical run and return long-term stocks to −20°C immediately afterward.

For definitive stability, solubility limits, and concentration verification, consult the product’s CoA/Spec Sheet. Research use only.

Structure & Identity

Imatinib‑d4 is the stable‑isotope–labeled analog of imatinib, with four deuterium atoms incorporated to provide a defined mass shift for MS-based analyses.

  • Item-specific identifiers (from Product Data)

    • SKU: I649056
    • CAS: 1134803-16-9
    • InChIKey: Not specified for this item; refer to CoA/Spec Sheet.
    • SMILES: Not specified for this item; refer to CoA/Spec Sheet.
    • Molecular Formula: Not specified for this item; refer to CoA/Spec Sheet.
    • Molecular Weight: Not specified for this item; refer to CoA/Spec Sheet.
  • Structural features (general, literature description of imatinib core)

    • Consists of a substituted benzamide linked to a diaminopyrimidine/aminopyridyl pharmacophore and a N-methylpiperazinylmethyl moiety.
    • Functional groups: secondary amide, anilide, tertiary amine (piperazine), heteroaromatic nitrogen donors (pyridine/pyrimidine), and multiple diarylamine linkages.
    • Imatinib‑d4 retains the parent scaffold; four hydrogen atoms are replaced with deuterium at defined positions (supplier-specific; consult CoA for exact labeling pattern).
  • 2D structure (verbal depiction, literature)

    • A central benzamide ring para‑substituted with a chlorophenyl/heteroaryl-bridged anilide (in the imatinib family) and bearing a benzylic linker to a N‑methylpiperazine ring; the heteroaromatic system includes a pyridyl–pyrimidyl segment engaged via an anilide nitrogen.

Notes: Exact isotopic labeling positions and stereochemical annotations (if any) are product-specific. Refer to the CoA/Spec Sheet for definitive structure and identifiers.

Synthetic Utility

Imatinib‑d4 is generally not a building block for synthesis; rather, it is a labeled analog of a finished small molecule. Nonetheless, it can support chemical and biochemical investigations.

  • Utility in synthesis/chemistry laboratories (research context)

    • Reaction monitoring: As an isotopically distinguishable standard, d4 material can aid in quantifying imatinib during synthetic route scouting, crystallization optimization, or salt-screen studies by LC–MS.
    • Isotope effects: While deuterium kinetic isotope effects are typically small for non-exchangeable positions, comparative studies of degradation or photostability can be conducted using d0 vs d4 materials to probe mechanisms (literature practice).
  • Not typically applicable

    • It is not a reagent for functional group interconversion, coupling, or protection strategies.
  • Retrosynthetic value

    • None; this compound represents an end-state scaffold rather than an intermediate.

For preparative or discovery chemistry, focus on parent building blocks; deploy Imatinib‑d4 for quantitative analytics and stability profiling.

Target Specificity

Not applicable. This product is a small-molecule isotope-labeled standard, not an antibody, protein, or affinity reagent. There are no clone IDs, epitopes, or species reactivity parameters associated with this item.

Frequently Asked Questions

What is the purity of this product?
This product is supplied at ≥99% purity (chemical assay). Lot-specific values are stated on the Certificate of Analysis.
How should this product be stored?
Store at ?20 °C. Freezer storage is required to maintain the specified shelf life.
How is this product shipped?
This product ships in an insulated container with ice pads. Unpack on arrival and transfer it to the storage condition stated above.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is 1134803-16-9, the molecular formula is C29H27D4N7O, and the molecular weight is 497.63 g/mol.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.