Methylene Blue Staining Solution (0.2%) - BioReagent

CAS: 7220-79-3 Cat. No.: M1528787 Formula: C₁₆H₂₄ClN₃O₃S Molecular Weight: 373.9 Beilstein Registry Number: 3599847 EC Number: 615-731-6
AVAILABLE TO ORDER
GRADE & PURITY BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. Biological Stain ? Biological stain grade — dyes characterized for staining cells and tissues. Use in histology and microscopy where staining consistency matters. 0.2% in water
Storage
Protected from light,Room temperature
Shipped In
Normal
★
Size
USA
Germany (EU)*
Price
Qty
100ml
M1528787-100ml
Made to order · 8–12 wks
$16.90
500ml
M1528787-500ml
Made to order · 8–12 wks
$59.90
Enter a quantity for the sizes you want to add.

Overview

Methylene blue, also known as methylthioninium chloride, basic blue 9, etc., has the molecular formula C₁₆H₂₄ClN₃O₃S (hydrated form), a molecular weight of 373.9, and a CAS number of 7220-79-3.

Methylene blue staining solution is commonly used for staining silk, paper, bacteria, cells, etc. Because it is easily oxidized, staining results are not suitable for long-term storage.

Procedure (for reference only):

1. Sample Processing

① Paraffin sections

Deparaffinize in xylene for 5–10 min.

Replace with fresh xylene and deparaffinize again for 5–10 min.

Immerse in anhydrous ethanol for 5 min.

Rinse in distilled water for 2 min.

② Frozen sections

Rinse in distilled water for 2 min.

③ Cultured cells

Fix with 4% paraformaldehyde for at least 10 min.

Wash with distilled water for 2 min.

Replace with fresh distilled water and wash again for 2 min.

2. Methylene Blue Staining

Stain with Methylene Blue Staining Solution (0.2%) for 3–10 min (the time can be adjusted according to the staining results and requirements).

Wash thoroughly with distilled water or tap water, then observe and photograph.

Staining Results:

Tissues or cells: blue

Precautions:

1.When using this reagent for the first time, it is recommended to perform a preliminary experiment with 1–2 samples.

2.For your safety and health, please wear a lab coat and disposable gloves during operation.

3.This product is for research use only and must not be used for any other purposes.

Specifications

Specifications & Purity
BioReagent, Biological Stain, 0.2% in water
Stability And Storage
Store at RT long term (12 months). Store in the dark.
Storage
Protected from light,Room temperature
Shipped In
Normal
Grade
Biological Stain, BioReagent
Product Line
M1528787-100ml
Names and Identifiers
Isomeric SMILES
CN(C)C1=CC2=C(C=C1)N=C3C=CC(=[N+](C)C)C=C3S2.O.O.O.[Cl-]
WGK Germany
2
Molecular Weight
373.9
Beilstein
3599847
Reaxys
16692608
Reaxys-RN_link_address
https://www.reaxys.com/reaxys/secured/hopinto.do?context=S&query=IDE.XRN=16692608&ln=

Advanced Data

Certificates (CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Chemical and Physical Properties
SensitivityLight-sensitive
Melt Point235°C
Safety and Hazards(GHS)
Pictogram(s)
GHS08,   GHS07
Signal
Warning
Hazard Statements

H315:Causes skin irritation

H319:Causes serious eye irritation

H335:May cause respiratory irritation

H373:May causes damage to organs through prolonged or repeated exposure

H302:Harmful if swallowed

Precautionary Statements

P261:Avoid breathing dust/fume/gas/mist/vapors/spray.

P305+P351+P338:IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do - continue rinsing.

P280:Wear protective gloves/protective clothing/eye protection/face protection.

P302+P352:IF ON SKIN: wash with plenty of water.

P321:Specific treatment (see ... on this label).

P405:Store locked up.

P501:Dispose of contents/container to an approved waste disposal plant.

P264:Wash hands [and …] thoroughly after handling.

P260:Do not breathe dust/fume/gas/mist/vapors/spray.

P271:Use only outdoors or in a well-ventilated area.

P270:Do not eat, drink or smoke when using this product.

P304+P340:IF INHALED: Remove person to fresh air and keep comfortable for breathing.

P403+P233:Store in a well-ventilated place. Keep container tightly closed.

P362+P364:Take off contaminated clothing and wash it before reuse.

P330:Rinse mouth.

P264+P265:Wash hands [and …] thoroughly after handling. Do not touch eyes.

P301+P317:IF SWALLOWED: Get medical help.

P337+P317:If eye irritation persists: Get medical help.

P332+P317:If skin irritation occurs: Get medical help.

P319:Get medical help if you feel unwell.

WGK Germany
2
Reaxys
16692608
Reaxys-RN_link_address
https://www.reaxys.com/reaxys/secured/hopinto.do?context=S&query=IDE.XRN=16692608&ln=
Solution Calculators
Reviews

Customer Reviews

Application Protocols

The following are general, literature-based protocols for common uses of a 0.2% methylene blue solution. Optimize for your specimens and instrumentation.

  • Simple cell stain (wet mount):

    1. Place a drop of sample on a clean slide. 2) Add 1–2 drops of 0.2% solution; incubate 1–3 min. 3) Gently rinse with water or blot edge with tissue to reduce excess. 4) Apply coverslip and examine by brightfield. Adjust time to modulate contrast/background.
  • Bacterial simple stain (smear):

    1. Prepare thin smear, air-dry, and heat-fix briefly. 2) Flood with 0.2% solution for 1–2 min. 3) Rinse with water and blot dry. 4) Observe under oil immersion as needed. Overstaining increases background; extend rinsing accordingly.
  • Plant epidermis (onion skin) stain:

    1. Mount epidermal peel in water. 2) Add a drop of 0.2% stain at coverslip edge; allow capillary action to draw dye across. 3) After 2–5 min, wick away excess with tissue and replace with water for better contrast.
  • Agarose gel post-stain for DNA (visible light):

    1. Dilute the 0.2% solution to 0.02% in water or 1× buffer (10 mL of 0.2% + 90 mL diluent). 2) Submerge gel and gently agitate 30–60 min. 3) Destain in water/buffer with changes until bands are visible (1–4 h). Sensitivity is lower than fluorescent dyes; thicker gels require longer times.

General tips:

  • Protect from intense light during long incubations to minimize photobleaching or photo-oxidation.
  • Use clean glassware to reduce nonspecific adsorption/background.
  • Document optimal times for your sample type to ensure reproducibility.
Biological Roles

This section discusses general, literature-based properties of methylene blue relevant to lab staining; it does not describe therapeutic or clinical uses.

  • Binding/interactions (general):

    • Cationic phenothiazinium dye that associates with negatively charged biomolecules (nucleic acids, acidic polysaccharides) via electrostatic interactions and, to a lesser extent, intercalation with nucleic acids.
    • Stains nuclei and RNA-rich regions, enhancing contrast in brightfield microscopy.
  • Redox/photosensitization:

    • Under illumination, acts as a photosensitizer generating reactive oxygen species; can photobleach or damage sensitive biomolecules with prolonged exposure.
    • Reversible reduction to leucomethylene blue provides a colorimetric redox indicator behavior in microbiological and biochemical assays.
  • Cell permeability:

    • Permeability varies by organism and fixation state. In live-cell wet mounts, brief exposure enhances contrast without extensive uptake; in fixed/permeabilized samples, uptake is stronger, requiring careful destaining to control background.

These roles underpin its utility in teaching labs and routine microscopy, where quick, visible staining is needed without fluorescence instrumentation.

Buffer Applications

This product is not a buffering reagent. However, it is commonly used in conjunction with standard biological buffers.

  • Compatible buffers (general practice):

    • Phosphate-buffered saline (PBS), Tris-buffered saline (TBS), or deionized water are suitable for dilution, rinsing, and destaining steps in staining workflows.
    • High concentrations of certain salts or polyvalent anions may influence dye-background adsorption; optimize rinses accordingly.
  • pH considerations:

    • Methylene blue remains cationic and strongly colored across neutral pH; extreme pH can affect binding and background. If sensitivity to pH is expected in your assay, conduct a small-scale test.

Item-specific buffer composition or recommended pH ranges are Not specified for this item; refer to CoA/Spec Sheet.

Green Alternatives

Methylene blue staining solution is water-based and can be a safer, non-UV alternative for certain visualization tasks.

  • Environmental/health profile (general):

    • Aqueous vehicle avoids volatile organic solvents.
    • Non-fluorescent visualization under white light can reduce UV exposure compared to ethidium bromide methods.
  • Alternatives and trade-offs (general comparison):

| Application | Greener or alternative option | Pros | Cons | |---|---|---|---| | DNA gel staining | Methylene blue (this product) | No UV needed; aqueous; readily disposable per local rules | Lower sensitivity; longer staining/destaining | | DNA gel staining | SYBR Safe, GelRed (fluorescent) | Higher sensitivity; visible-blue transilluminators | Cost; still specialized disposal needed | | General cell staining | Toluidine blue, Azure B | Similar handling; aqueous | Different color tone; metachromasia may complicate interpretation | | Gram staining counterstain | Safranin (aqueous/alcoholic) | Standardized protocols | Requires multiple reagents, sometimes alcohol handling |

Note: Waste disposal requirements vary. Always follow institutional and local regulations.

Pharmaceutical Uses

This product is supplied for research use only and is not intended for clinical or therapeutic applications.

  • Formulation/excipient context (general, non-clinical):

    • In manufacturing and quality control environments, methylene blue solutions are sometimes used as tracer dyes for leak testing and equipment validation because of their strong visible color. Such uses are process tools rather than excipients.
  • Pharmacopeial status and specification limits for this specific SKU: Not specified for this item; refer to CoA/Spec Sheet.

Users in regulated environments should qualify the reagent under their internal procedures and consult applicable standards before use in GMP settings.

Physical Properties
  • Item-specific properties (0.2% staining solution):

    • Concentration: 0.2% (label claim)
    • Appearance: Not specified for this item; refer to CoA/Spec Sheet.
    • Density, pH, refractive index, conductivity: Not specified for this item; refer to CoA/Spec Sheet.
    • Solubility/miscibility: Aqueous solution; fully miscible with water (general for such formulations). Item-specific miscibility limits not specified.
  • Methylene blue dye (literature/general values for reference):

    • Solubility: highly soluble in water; soluble in ethanol (polar protic); limited solubility in nonpolar solvents.
    • Visible absorption (H2O): strong band λmax ~ 660–668 nm (often ~664–665 nm) with high molar absorptivity (ε on the order of 7×10^4 M−1·cm−1) (literature).
    • Redox behavior: reversible redox couple between the blue oxidized form and the colorless leuco form; reduction favored in the presence of reducing agents and low O2 (literature).
  • Boiling point, melting point, logP, pKa for this formulated solution: Not specified for this item; refer to CoA/Spec Sheet.

Practical note: The apparent color intensity of the 0.2% solution depends on path length and container geometry; strong absorbance may saturate spectrophotometers at standard 1 cm paths without dilution.

Quality & Grades
  • Item grade: BioReagent (per Product Data).

    • Meaning (general): BioReagent-grade materials are suitable for common biological and biochemical laboratory applications, emphasizing consistency, low bioburden, and performance in staining/assay workflows. They are not certified for clinical/diagnostic use.
  • What BioReagent means for this product:

    • Ready-to-use aqueous solution formulated for reproducible staining performance in teaching and research labs.
    • Low particulate content and consistent color strength are typically expected for uniform staining. Item-specific limits are Not specified for this item; refer to CoA/Spec Sheet.
  • Stabilizers/preservatives:

    • Not specified for this item; refer to CoA/Spec Sheet. If present, stabilizers can influence compatibility with downstream enzymatic assays—perform a small-scale test when assay sensitivity is critical.
  • UV/visible absorbance background:

    • Not specified for this item; refer to CoA/Spec Sheet. As a strong chromophore, the solution will show intense absorbance near ~664 nm (literature for methylene blue).
  • Suitability: For research use only (per Product Data). Not for drug, diagnostic, or household use.

Reaction & Applications

This product is primarily used for biological staining, not for synthetic reactions. Key laboratory applications (general/literature-based):

  • Simple biological stains:

    • Wet-mount staining of eukaryotic cells (e.g., onion epidermis, cheek cells, yeast) to enhance contrast of nuclei and cytoplasmic features.
    • Bacterial simple staining to visualize cell morphology. Rinsing with water reduces background.
  • Counterstaining:

    • As a blue counterstain in multi-stain protocols where a non-fluorescent, visible dye is preferred.
  • Nucleic acid visualization (visible light):

    • Post-stain agarose gels after electrophoresis. Typical working solutions are 0.005–0.02% with extended staining and destaining in water or buffer (literature). The 0.2% stock can be diluted accordingly.
  • Redox indicator/photosensitizer (chemistry labs, general):

    • Methylene blue participates in redox indicator assays (e.g., dye resazuration tests) and can act as a photosensitizer; however, this formulated solution is optimized for staining, not calibrated photoredox experiments.

Practical tips:

  • Avoid strong reducing agents during use; they may decolorize the dye (leuco form) and impair staining.
  • Staining intensity depends on time, temperature, and ionic strength; optimize empirically for your specimen.
  • For gels, gentle agitation improves uniformity; excessive time increases background and destaining requirements.
Reaction Conditions

Not typically applicable to this staining solution. For completeness, general literature notes on the dye’s behavior are provided for researchers considering non-standard uses:

  • Photoredox catalysis (literature/general):

    • Methylene blue has been used as an organic photocatalyst under blue light, often in polar solvents (water, MeOH, MeCN). Catalyst loadings range from 0.1–5 mol% (as dye), with irradiation times from minutes to hours depending on substrate and light intensity. Oxygen can participate (aerobic oxidations), but conditions vary widely. These are general literature ranges and not specifications for this product.
  • Redox indicator (literature/general):

    • The dye interconverts between blue (oxidized) and colorless (leuco) forms in the presence of reductants/oxidants. Practical conditions depend on system composition and are not standardized here.

For staining workflows, see Application Protocols for practical, relevant conditions.

Safety & Handling
  • GHS classification, signal word, hazard statements, and pictograms for this specific item: Not specified for this item; refer to the product SDS for authoritative information.

  • General laboratory precautions (good practice):

    • Wear appropriate PPE: lab coat, safety glasses, and suitable chemical-resistant gloves.
    • Avoid contact with skin and eyes; methylene blue can cause persistent staining of skin, fabrics, and benchtops.
    • Prevent aerosol/atomization; handle to minimize spills and splashes.
    • Work with care around optical equipment and light-sensitive assays; methylene blue is a photosensitizer and can generate reactive oxygen species under bright light.
  • Incompatibilities/considerations (general):

    • Reducing agents (e.g., ascorbate, dithionite, sodium borohydride) can decolorize the dye by forming leucomethylene blue.
    • Strong oxidizers may degrade the dye or alter staining performance.
    • Avoid contamination with biological samples or buffer salts that could precipitate at high ionic strength (rare at 0.2%, but possible in unusual formulations).
  • First-aid overview (general):

    • Skin: Wash with soap and water; mechanical removal aided by detergent. Staining may persist temporarily.
    • Eyes: Rinse cautiously with water for several minutes; remove contact lenses if present and easy to do; seek medical advice per SDS guidance.
    • Ingestion/inhalation: Seek medical advice if symptoms occur; provide SDS to responders.

Always consult the SDS for this specific SKU for complete hazard, exposure limits, and emergency procedures.

Solvent Selection

This product is an aqueous 0.2% staining solution and is typically used as supplied.

  • Polarity/miscibility:

    • Water-based, fully miscible with water and common biological buffers (PBS, TBS) at typical working dilutions.
    • Miscibility with organic solvents is not generally required for staining workflows; if blending with alcohol (e.g., for rapid fixation/staining), verify compatibility on a small scale.
  • When to use as-is vs alternatives:

    • Use as-is for light microscopy simple stains of cells/tissues, and as a counterstain in wet mounts.
    • For nucleic acid gel staining, many labs dilute methylene blue to ~0.02% or less; the 0.2% solution can be diluted 1:10–1:50 with buffer/water depending on the application (general guidance).
  • Comparison (general):

    • Versus crystal violet or safranin: MB provides a blue contrast, good for general morphology; less hazardous than some triphenylmethane dyes.
    • Versus ethidium bromide (nucleic acids): MB is non-fluorescent but visible in ambient light; lower sensitivity but avoids UV illumination.

Note: Item-specific solvent compatibility claims and pH tolerance are Not specified for this item; refer to CoA/Spec Sheet.

Storage & Reconstitution
  • Item-specific storage: Store at room temperature (per Product Data). Shipped at ambient temperature (Normal).

  • Light sensitivity (general): Protect from prolonged exposure to strong light. Store in a tightly closed, light-protective container to maintain color strength.

  • Stability/shelf life: Not specified for this item; refer to CoA/Spec Sheet.

  • Reconstitution: Not applicable. This is a ready-to-use 0.2% solution. If concentration adjustments are needed, dilute with deionized water or appropriate buffer (e.g., PBS) using clean, dye-free containers.

  • Handling notes:

    • If any precipitate forms (rare), warm gently to room temperature and mix to redissolve; verify performance on a small sample.
    • Avoid microbial contamination; dispense with clean pipettes and consider aliquoting for frequent use.

Always refer to the product label and CoA/SDS for item-specific guidance.

Structure & Identity

This product is a ready-to-use aqueous dye formulation: Methylene Blue Staining Solution (0.2%). It is intended for laboratory staining and visualization of biological specimens.

  • Item-specific identifiers (this catalog lot):

    • CAS: Not specified for this item; refer to CoA/Spec Sheet.
    • Molecular formula: Not specified for this item; refer to CoA/Spec Sheet.
    • Molecular weight: Not specified for this item; refer to CoA/Spec Sheet.
    • SMILES / InChIKey: Not specified for this item; refer to CoA/Spec Sheet.
  • About the active dye (methylene blue, literature/general):

    • Common form: methylene blue chloride (basic blue 9)
    • Typical molecular formula (dye base, chloride salt): C16H18ClN3S (literature)
    • Typical molecular weight: ~319.85 g/mol (literature)
    • InChIKey (methylene blue chloride, literature): WATHJZPJSRABOQ-UHFFFAOYSA-M
    • Structural features (2D description, literature): a phenothiazin-5-ium core (tricyclic ring system with a central thiazine ring containing S and N), N,N-dimethylamino substituents para to the heteroatoms, and a cationic quaternized nitrogen; typically paired with chloride as counter-anion. The chromophore is delocalized across the phenothiazinium system, conferring a deep blue color.

Notes: The above structural details describe the active dye component in general; exact identity/hydration state and concentration of excipients in this 0.2% solution should be confirmed from the item’s CoA/Spec Sheet.

Synthetic Utility

This product is a prepared biological staining solution and is not typically employed as a synthetic building block.

  • Chemistry context (literature/general):
    • Methylene blue can serve as a photoredox catalyst or redox mediator in organic transformations under visible light. However, this 0.2% aqueous solution is optimized for staining and contains water and possibly salts/preservatives that may not be compatible with anhydrous or oxygen-sensitive chemistry.

For synthetic applications, source neat dye of defined grade and prepare solutions under conditions tailored to the intended reaction.

Target Specificity

Not an antibody or targeted affinity reagent. Methylene blue is a general cationic dye that non-specifically associates with negatively charged cellular components (general/literature). No clone, isotype, antigen specificity, or species reactivity applies to this product.

Frequently Asked Questions

How should this product be stored?
Store at room temperature.

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.