Blood Potassium (K⁺) Concentration Assay Kit (NaTPB, Micro Method) - BioReagent, high purity

Cat. No.: G1501769
AVAILABLE TO ORDER
GRADE & PURITY BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility.
 ·  off list, applied to all prices below.
Size
Status
Price
Qty
96T
G1501769-96T
8-12 wks(?) Production requires sourcing of materials. We appreciate your patience and understanding.
$59.90
Enter a quantity for the sizes you want to add.
🧪

Why this grade

BioReagent BioReagent for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Store at 2-8°C,Protected from light Ships Wet ice Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

Overview

Blood potassium plays a crucial role in maintaining normal osmotic pressure, acid-base balance, sugar and protein metabolism, and ensuring normal neuromuscular function. Its concentration is closely related to various important physiological functions. Abnormally high or low levels can disrupt normal physiological activities. Hyperkalemia increases neuromuscular excitability but decreases myocardial excitability, leading to bradycardia. Hypokalemia can cause muscle weakness or even flaccid paralysis, increase myocardial excitability, and result in tachycardia, arrhythmias, or even cardiac arrest during systole.


Detection Principle: Potassium ions (K⁺) in serum react with sodium tetraphenylboron to form water-insoluble potassium tetraphenylboron. The turbidity produced is directly proportional to the potassium ion concentration within a certain range. The serum potassium ion content is determined by measuring this turbidity.


Applicable Sample: Serum


G1501769
Component
96 T
Storage
G1501769A
Extraction Buffer
50 mL
2-8℃
G1501769B
ReagentⅠ
2.4 mL
2-8℃
G1501769C
ReagentⅡ
1EA
2-8℃. Store in the dark.
G1501769D
ReagentⅢ
20 mL
2-8℃
G1501769E
Standard
1 mL
2-8℃

Note: Before formal testing, it is recommended to perform a preliminary test with 2-3 samples expected to have significant differences.


User-Prepared Instruments and Reagents

  • Microplate reader or visible spectrophotometer (capable of measuring absorbance at 520 nm)

  • 96-well plate or micro glass cuvettes, adjustable micropipettes and tips

  • Centrifuge

  • Deionized water, Concentrated Sulfuric Acid


Experimental Procedure

1. Reagent Preparation

Reagent Name
Reagent Preparation
Notes
Extraction Buffer
/Slightly irritating. Use appropriate personal protective equipment during handling.
Working Extraction Buffer
Prepare before use: Mix Extraction Buffer (mL) and Concentrated Sulfuric Acid (μL) in a 5:12 ratio as needed. Prepare freshly for each use.
If precipitate forms, prepare a new batch.
Reagent Ⅱ Working Solution
Prepare before use: Add the entire contents of Reagent Ⅰ into the Reagent Ⅱ vial. Mix well. This is the Reagent Ⅱ Working Solution.
Can be stored at 4°C protected from light for one week.
ReagentⅢ
Preheat in a 25°C water bath for at least 30 minutes before use.
/
Standard
Ready-to-use; Equilibrate to room temperature before use.
Store at 4°C.


2. Sample Preparation

Serum Pretreatment: Take a microcentrifuge tube. Sequentially add 50 μL of serum and 450 μL of Working Extraction Buffer. Mix thoroughly. Centrifuge at 8,000 rpm for 10 minutes at room temperature (approximately 25°C). Collect the supernatant for assay.


3. Assay Steps

3.1 Preheat the microplate reader or visible spectrophotometer for at least 30 minutes. Set the wavelength to 520 nm. For spectrophotometers, zero the instrument with deionized water.

3.2 Assay Procedure (perform in a 96-well plate or micro glass cuvette):

ReagentBlank Well (μL)Standard Well (μL)Test Well (μL)
Deionized Water4000
Standard
0
40
0
Supernatant
0
0
40
Reagent Ⅱ Working Solution
2020
20

Mix well and let stand for 5 minutes.


ReagentⅢ
140140
140

3.3 Mix well after addition. Measure the absorbance at 520 nm. Record the absorbance of the Blank well as A blank , the Standard well as A standard , and the Test well as A test .

Note:

  • The Blank and Standard tubes only need to be set up 1-2 times.

  • It is recommended to perform a preliminary test with 2-3 samples expected to have significant differences before the formal experiment. If A <sub> test </sub> is less than 0.02, consider increasing the sample volume appropriately. If A <sub> test </sub> is greater than 1.1, further dilute the sample with Working Extraction Buffer (multiply the result by the dilution factor) or reduce the sample volume used for extraction.


4. Calculation of Results

Note: We provide both the derived formula and a simplified formula. They are equivalent. It is recommended to use the simplified formula in bold for final calculation.

Blood Potassium Concentration (mmol/L) = [C Standard × (A test - A blank ) ÷ (A standard - A blank )] × n = 5 × (A test - A blank ) ÷ (A standard - A blank )

Parameter Definitions:

  • C Standard : 0.5 mmol/L

  • n: Sample dilution factor (10)

Precautions

1. Before formal testing, it is recommended to perform a preliminary test with 2-3 samples expected to have significant differences.

2. Biochemical reagents are generally irritating and potentially biologically toxic. For your safety and health, please use appropriate biosafety precautions throughout the experiment, including wearing lab coats, masks, gloves, and head covers. Perform experiments in a fume hood or biosafety cabinet.

3. This product is for research use only. Not for use in clinical diagnosis.

Storage and Shipping
Storage
Store at 2-8°C,Protected from light
Shipped In
Wet ice
Stability And Storage
Store at 2-8℃ long term (12 months). Store in the dark.

Documentation

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Certificates(CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Solution Calculators
Reviews

Customer Reviews

Need help choosing the grade?

Our grade selection guide covers purity, stabilizer status, and application suitability for all variants in our catalog.

View BioReagent grade guide →

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.