Determine the necessary mass, volume, or concentration for preparing a solution.
BioReagent, for western blot, for protein analysis BioReagent,for Protein analysis,for Western blot for sensitive chromatographic and analytical workflows requiring minimal baseline interference.
Store at 2-8°C,Room temperature,Store at -20°C Ships Ice chest + Ice pads Check lot-specific COA for exact specifications.
SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.
Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.
This kit innovatively adopts a column-based purification method to rapidly, gently, and efficiently lyse animal tissues or cells for total protein extraction. It provides both denaturing and native lysis buffers, allowing users to select the appropriate option based on downstream application requirements. The entire extraction process takes only 1–8 minutes. Thanks to the column purification technology, it can process sample-lysis buffer mixtures as small as 20 μL and up to 500 μL, yielding protein solutions with concentrations of 2–8 mg/mL while effectively preventing protein loss. The extracted proteins can be quantified using the BCA method (Cat. No.: R1491648/B665595).
|
Key Features
1.Simple and rapid operation: Denatured total proteins can be obtained in as little as 1 minute.
2.No protein loss: Efficiently extracts DNA-binding proteins by disrupting DNA duplexes.
3.Small sample volume, high yield: Processes mixtures as small as 20 μL, yielding protein concentrations of 2–8 mg/mL.
4.Versatile applications: Includes two lysis buffers for extracting both denatured and native proteins.
Protocol
1、Extraction of Denatured Total Protein
1.Pre-chill the purification column and collection tube on ice.
2.Sample processing: Add protease inhibitor cocktail to the denaturing lysis buffer at a 1:100 ratio shortly before use.
2.1 Adherent cells:
Wash cells with pre-chilled 1× PBS and aspirate the supernatant.
Add the volume of denaturing lysis buffer specified in the appendix table to cover the culture surface, and pipette to mix.
2.2 Suspension cells:
Collect cells by low-speed centrifugation.
Wash with pre-chilled 1× PBS, vortex, and centrifuge at 3,000 rpm for 2–3 minutes.
Resuspend the cell pellet in PBS equal to the pellet volume.
Add the specified volume of denaturing lysis buffer and vortex to lyse.
Note: Partial incomplete lysis does not affect protein extraction. If the lysate is too viscous, directly transfer it to the purification column.
2.3 Tissue samples:
Place 15–20 mg of tissue on the purification column.
Grind 50–60 times with a plastic pestle.
Add 200 μL denaturing lysis buffer and grind another 30–60 times.
Adjust lysis buffer volume proportionally for larger or smaller samples.
Note: Reusable plastic pestles should be thoroughly rinsed with distilled water and dried.
3.Centrifugation:
3.1 Adherent or suspension cells: Transfer the lysate to the pre-chilled purification column and centrifuge at 14,000–16,000 rpm for 30 seconds.
3.2 Tissue samples: Incubate the column at room temperature for 1–2 minutes, then centrifuge at 14,000–16,000 rpm for 1–2 minutes.
4.Immediately place the collection tube on ice and discard the purification column. Denatured total protein extraction is complete.
2、Extraction of Native Total Protein
1.Pre-chill the native lysis buffer, purification column, and collection tube on ice.
2.Sample processing: Add protease inhibitor cocktail to the native lysis buffer at a 1:100 ratio shortly before use.
2.1 Adherent cells:
Wash cells with pre-chilled 1× PBS and aspirate the supernatant.
Add the specified volume of native lysis buffer and incubate on ice for 3–5 minutes. Pipette to mix.
2.2 Suspension cells:
Collect, wash, and resuspend cells as described in section I.
Add native lysis buffer, vortex for 15 seconds, incubate on ice for 3–5 minutes, and vortex again for 10 seconds.
2.3 Tissue samples:
Grind tissue as described in section I, using native lysis buffer.
3.Centrifugation:
3.1 Adherent or suspension cells: Centrifuge at 14,000–16,000 rpm for 30 seconds.
3.2 Tissue samples: Incubate on ice for 5 minutes (open lid), then close the lid and centrifuge at 4°C and 14,000–16,000 rpm for 1–2 minutes.
4.Immediately place the collection tube on ice and discard the purification column. Native total protein extraction is complete.
|
Appendix: Cell Number vs. Lysis Buffer Volume
High viscosity of the lysate is normal when using this kit.
For safety, wear a lab coat and disposable gloves during operation.
For research use only.
Comprehensive hazard, handling, storage, and regulatory compliance document.
Download SDS →Lot-specific quality data. Enter your lot number to retrieve the exact COA.
Look up COA →Full quality attributes and acceptance criteria for this grade.
View spec sheet →Find and download the COA for your product by matching the lot number on the packaging.
| Lot Number | Certificate Type | Date | Item |
|---|---|---|---|
| Certificate of Analysis | Jul 07, 2026 | C1491689 | |
| Certificate of Analysis | Apr 03, 2026 | C1491689 | |
| Certificate of Analysis | Nov 03, 2025 | C1491689 |
Our grade selection guide covers purity, stabilizer status, and application suitability for all variants in our catalog.
View BioReagent grade guide → View for Protein analysis grade guide → View for Western blot grade guide →