JC-1 - A cationic, fluorescent, carbocyanine dye that can be used as a ratiometric indicator of mitochondrial potential δΨm in cells, tissues, and isolated mitochondria. , CAS No.47729-63-5

CAS: 47729-63-5 Cat. No.: J755442 Formula: C25H27Cl4N4・I Molecular Weight: 652.2 PubChem CID: 5492929
AVAILABLE TO ORDER
GRADE & PURITY A cationic, fluorescent, carbocyanine dye that can be used as a ratiometric indicator of mitochondrial potential δΨm in cells, tissues, and isolated mitochondria.
Storage
Store at -20°C
Shipped In
Ice chest + Ice pads
★
Size
USA
Germany (EU)*
Price
Qty
5mg
J755442-5mg
Made to order · 8–12 wks
$797.90
Enter a quantity for the sizes you want to add.

Overview

A cationic, fluorescent, carbocyanine dye that can be used as a ratiometric indicator of mitochondrial potential ΔΨm in cells, tissues, and isolated mitochondria. It labels mitochondria with high membrane potential orange and mitochondria with low membrane potential green. Mitochondrial depolarization is indicated by a decrease in the red/green fluorescence intensity ratio. Ideal for detection of collapse of ΔΨm induced by uncouplers of mitochondrial respiration. The potential-sensitive color shift is due to concentration-dependent formation of red fluorescent J-aggregates. JC-1 has also been used in a functional assay of multidrug-resistance cells and in apoptosis-related mitochondrial modifications.
A cationic, fluorescent, carbocyanine dye that can be used as a ratiometric indicator of mitochondrial potential ΔΨm in cells, tissues, and isolated mitochondria. Mitochondrial depolarization is indicated by a decrease in the red/green fluorescence intensity ratio. The potential-sensitive color shift is due to concentration-dependent formation of red fluorescent J-aggregates. Ideal for detection of collapse of ΔΨm induced by uncouplers of mitochondrial respiration. JC-1 has also been used in a functional assay of multidrug-resistance cells and in apoptosis-related mitochondrial modifications.

Specifications

Specifications & Purity
A cationic, fluorescent, carbocyanine dye that can be used as a ratiometric indicator of mitochondrial potential δΨm in cells, tissues, and isolated mitochondria.
Biochemical and Physiological Mechanisms
Cell permeable: noPrimary TargetUsed as a ratiometric indicator of mitochondrial potential δΨm in cells, tissues, and isolated mitochondriaProduct does not compete with ATP.Reversible: no
Storage
Store at -20°C
Shipped In
Ice chest + Ice pads
This product requires cold chain shipping. Ground and other economy services are not available.
Names and Identifiers
Canonical Smiles
CCN1C2=CC(=C(C=C2[N+](=C1C=CC=C3N(C4=CC(=C(C=C4N3CC)Cl)Cl)CC)CC)Cl)Cl.[I-]
IUPAC Name
5,6-dichloro-2-[(E)-3-(5,6-dichloro-1,3-diethylbenzimidazol-3-ium-2-yl)prop-2-enylidene]-1,3-diethylbenzimidazole;iodide
InChIKey
FYNNIUVBDKICAX-UHFFFAOYSA-M
INCHI
1S/C25H27Cl4N4.HI/c1-5-30-20-12-16(26)17(27)13-21(20)31(6-2)24(30)10-9-11-25-32(7-3)22-14-18(28)19(29)15-23(22)33(25)8-4;/h9-15H,5-8H2,1-4H3;1H/q+1;/p-1
Isomeric SMILES
CCN1C2=CC(=C(C=C2[N+](=C1/C=C/C=C3N(C4=CC(=C(C=C4N3CC)Cl)Cl)CC)CC)Cl)Cl.[I-]
PubChem CID
5492929
Molecular Weight
652.2

Advanced Data

Taxonomic Classification

Taxonomy Tree

KingdomOrganic compounds
SuperclassOrganoheterocyclic compounds
ClassBenzimidazoles
SubclassNot available
Intermediate Tree Nodes Not available
Direct ParentBenzimidazoles
Alternative Parents N-substituted imidazoles  Benzenoids  Aryl chlorides  Heteroaromatic compounds  Ketene acetals  Azacyclic compounds  Organopnictogen compounds  Organonitrogen compounds  Organochlorides  Organic iodide salts  Hydrocarbon derivatives  
Molecular FrameworkAromatic heteropolycyclic compounds
Substituents Benzimidazole - Aryl chloride - Aryl halide - Benzenoid - N-substituted imidazole - Azole - Heteroaromatic compound - Imidazole - Ketene acetal or derivatives - Azacycle - Organic nitrogen compound - Organohalogen compound - Organochloride - Organonitrogen compound - Organic salt - Organic iodide salt - Hydrocarbon derivative - Organopnictogen compound - Aromatic heteropolycyclic compound
DescriptionThis compound belongs to the class of organic compounds known as benzimidazoles. These are organic compounds containing a benzene ring fused to an imidazole ring (five member ring containing a nitrogen atom, 4 carbon atoms, and two double bonds).
External Descriptors cyanine dye - organic iodide salt
3D Structure
Interactive Chemical Structure Model





Certificates (CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Chemical and Physical Properties
SolubilityDMSO: 5 mg/mL
Molecular Weight652.200 g/mol
XLogP3
Hydrogen Bond Donor Count0
Hydrogen Bond Acceptor Count3
Rotatable Bond Count6
Exact Mass652.001 Da
Monoisotopic Mass650.003 Da
Topological Polar Surface Area15.300 Ų
Heavy Atom Count34
Formal Charge0
Complexity625.000
Isotope Atom Count0
Defined Atom Stereocenter Count0
Undefined Atom Stereocenter Count0
Defined Bond Stereocenter Count1
Undefined Bond Stereocenter Count0
The total count of all stereochemical bonds1
Covalently-Bonded Unit Count2
Documents & Articles
Solution Calculators
Reviews

Customer Reviews

Application Protocols

Tested applications, recommended dilutions, and step-by-step protocols are not specified for this item in the provided Product Data. Please refer to the product datasheet and SDS for authoritative, item-specific instructions.

Note: JC-1 is widely used in flow cytometry, fluorescence microscopy, and plate-based assays to assess mitochondrial membrane potential (general/literature). However, Aladdin provides application guidance on a per-item basis; consult the CoA/Spec Sheet for validated procedures.

Biological Roles

JC-1 has no endogenous biological role; it is a synthetic carbocyanine fluorophore used to report on mitochondrial physiology in cells (general/literature):

  • Mechanistic basis: JC-1 is a delocalized lipophilic cation. In polarized mitochondria (high negative matrix potential), it accumulates within the mitochondrial matrix and inner membrane, increasing local concentration to a level that favors formation of J-aggregates (red emission). Upon depolarization, accumulation decreases, the dye remains monomeric (green emission), and the red/green fluorescence ratio drops.
  • Readout features:
    • Ratiometric measurement (red/green) helps correct for dye loading and illumination changes, improving assay robustness.
    • Sensitive to acute changes in ΔΨm induced by ionophores (e.g., FCCP), respiratory chain inhibitors, or metabolic perturbations (literature/general).
  • Considerations and limitations:
    • Binding/partitioning can be influenced by cell type, mitochondrial mass, and plasma membrane permeability.
    • Serum proteins and intracellular nucleic acids can bind carbocyanines, potentially altering background.
    • Very high dye concentrations promote nonspecific aggregation and may increase phototoxicity.
  • Instrumentation: Compatible with common FITC/GFP-like (green) and PE/TRITC-like (red) channels; proper compensation or sequential acquisition mitigates spectral overlap (literature).

This information is provided as general biochemical context for JC-1’s use as a research probe. It does not constitute medical or clinical guidance.

Buffer Applications

JC-1 is not a buffering agent and is not used to control solution pH. Therefore, standard buffer formulation guidance (e.g., phosphate, HEPES, Tris) is not directly applicable to this product.

Practical notes for use with buffers (general/literature):

  • Working solutions are typically prepared by diluting a concentrated DMSO stock of JC-1 into physiological buffers (e.g., HBSS, PBS, or cell culture media) immediately before staining.
  • Maintain low final DMSO content (commonly ≤0.1–0.2% v/v) to minimize solvent effects on cells.
  • Avoid strong detergents or high serum content during the staining period, as these can alter dye partitioning and background fluorescence.

Item-specific buffer recommendations and validated recipes: Not specified for this item; refer to the product datasheet.

Green Alternatives

Environmental and safety perspective (general guidance): JC-1 is an effective ΔΨm indicator but, like many cyanine dyes, it is synthetic, non-biodegradable, and used with polar aprotic solvents (e.g., DMSO). Consider the following alternatives and tradeoffs when designing greener workflows (literature/general):

  • Alternative membrane potential probes:
    • TMRE/TMRM (tetramethylrhodamine ethyl/methyl ester): single-color, non-ratiometric; simpler spectra but more sensitive to loading differences; often used at lower concentrations, potentially reducing dye mass released in waste.
    • Rh123 (Rhodamine 123): established, relatively lower molecular weight; non-ratiometric and can exhibit photobleaching.
    • DiOC6(3): carbocyanine with different spectral properties; known nonspecific binding and phototoxicity concerns in some cells.
    • JC-10 (structural analog): designed to improve aqueous handling and signal separation vs JC-1; still a synthetic dye.

Comparison highlights (general):

  • JC-1: ratiometric (red/green), robust dynamic range; requires careful solvent handling and light protection.
  • TMRE/TMRM: simpler handling, strong signal; requires careful normalization due to non-ratiometric nature.
  • Operational “green” steps regardless of dye choice:
    • Minimize DMSO volume and prepare concentrated stocks to reduce solvent waste.
    • Optimize staining to use the lowest effective dye concentration and shortest effective incubation.
    • Use microplate formats and reduced volumes to limit waste streams.
    • Ensure proper hazardous waste segregation to prevent environmental release.
Pharmaceutical Uses

JC-1 is supplied for research use only. No pharmacopeial status, excipient role, or manufacturing/formulation use is provided for this item.

General remarks (non-clinical, non-therapeutic):

  • JC-1 is a laboratory indicator dye for assessing mitochondrial membrane potential in research settings (cell biology, toxicology screens, mechanistic studies). It is not used as a drug substance, drug product, or approved diagnostic reagent.
  • Because it is a highly conjugated fluorescent cation with an iodide counterion, it is not typically incorporated into pharmaceutical dosage forms as an excipient.

Item-specific pharmaceutical or regulatory designations: Not specified for this item; refer to CoA/Spec Sheet.

Physical Properties

Item-specific physical specifications: Not specified for this item; refer to CoA/Spec Sheet.

General/literature properties of JC-1 (for context; not item-specific specifications):

  • Physical form: typically supplied as an orange-red crystalline solid or lyophilized powder; strongly light sensitive.
  • Molecular weight: ~652 g/mol (iodide salt).
  • Solubility: high in polar aprotic organic solvents such as DMSO and DMF; sparingly soluble in pure water as free dye but readily usable in aqueous buffers after dilution from DMSO stocks; reduced solubility in nonpolar solvents (literature).
  • Aggregation behavior: forms J-aggregates in environments with high local concentration/ordered membranes; aggregation state strongly affects spectral properties (literature).
  • Spectral characteristics (fluorescence; literature values):
    • Monomer: Ex ~485–490 nm, Em ~525–535 nm (green).
    • J-aggregate: Ex ~525–545 nm, Em ~585–595 nm (red).
  • LogP/logD: not routinely reported due to salt/aggregation; effective hydrophobicity is high due to tetrachloro and tetraethyl substitutions (qualitative literature note).
  • pKa: not typically reported/relevant; dye is used as a permanently charged carbocyanine cation (literature).

Practical implications:

  • Prepare concentrated DMSO stocks to avoid premature aggregation/precipitation.
  • Protect from light at all times; fluorescence and performance degrade upon light and prolonged air exposure.
  • Avoid repeated freeze–thaw of stock solutions; aliquot when possible.
Quality & Grades

Item-specific grade/purity: Not specified for this item; refer to CoA/Spec Sheet.

Context and expectations (general guidance for fluorescent dyes):

  • Research-use-only designation: This product is intended solely for research and laboratory applications; not for diagnostic or therapeutic use.
  • Typical QC attributes for cyanine dyes (literature/general):
    • Identity confirmation by NMR/HRMS and/or HPLC–UV/Vis profile.
    • Purity assessed by HPLC (% area) and spectral homogeneity (consistent absorbance/fluorescence maxima and dye content).
    • Low levels of residual organic solvents and inorganic salts (reported on CoA when applicable).
  • Stabilizers: Dyes are sometimes supplied without stabilizers to avoid spectral interference; if stabilizers are used, they are disclosed on the CoA. For this item, stabilizer presence is not specified.
  • Batch-to-batch consistency: For fluorescence assays, consistent extinction coefficient and emission profile are critical; review the CoA for absorbance maxima and purity to ensure assay reproducibility.

Recommendations:

  • Verify the lot-specific purity and spectral characteristics on receipt (HPLC trace, UV–Vis spectrum) to align with your assay sensitivity requirements.
  • Where critical, perform a small pilot assay to confirm performance (signal-to-noise, aggregate/monomer ratio) before large studies.
Reaction & Applications

This product is primarily a fluorescent probe rather than a synthetic reagent. Accordingly, its most relevant applications are in bioanalytical assays (general/literature):

  • Mitochondrial membrane potential (ΔΨm) assessment: JC-1 accumulates in energized mitochondria, forming red-fluorescent J-aggregates; loss of ΔΨm shifts equilibrium toward green-fluorescent monomers. The red/green ratio provides a ratiometric readout that helps correct for dye loading, illumination, and detector variability.
  • Cell-based workflows: suitable for use with cultured mammalian cells, primary cells, and isolated mitochondria. Typical readouts include fluorescence microscopy, flow cytometry, and microplate readers equipped with appropriate filter sets (literature).
  • Advantages of ratiometry: mitigates artifacts from cell number, dye concentration, and illumination intensity; improves comparability across wells/experiments.
  • Controls and standards: include depolarizing controls (e.g., FCCP or CCCP) and hyperpolarizing controls (e.g., oligomycin) to bracket assay response; validate linearity and dynamic range for each cell type (general guidance).
  • Practical tips:
    • Prepare fresh working solutions immediately before staining to minimize aggregate nucleation in bulk solution.
    • Optimize loading time and temperature to balance sufficient mitochondrial uptake with minimal cytotoxicity.
    • Calibrate instrument settings to capture both green and red channels without spectral bleed-through; apply compensation in flow cytometry.

Note: The above are general literature-based application notes. This product’s specific validated uses are not provided in the Product Data; consult the product datasheet for any item-specific recommendations.

Reaction Conditions

Not typically applicable. JC-1 is used as a fluorescent probe in biological assays rather than as a reagent for chemical transformations.

General use conditions for staining workflows (literature/for context only; not item-specific specifications):

  • Solvent: DMSO for concentrated stock solutions; dilute into physiological buffers for working solutions.
  • Concentration: low micromolar working concentrations are commonly reported; optimize per cell type to balance signal and viability.
  • Temperature/time: incubation at 37°C for live cells for short periods (e.g., tens of minutes) is commonly reported; exact times require empirical optimization.
  • Controls: include depolarizing and hyperpolarizing agents to validate the dynamic range.
  • Detection: configure instruments to capture green (monomer) and red (J-aggregate) channels with appropriate filters; apply spectral compensation where necessary.

For item-specific, validated protocols and operating conditions, consult the product datasheet. No reaction chemistry conditions are applicable.

Safety & Handling

Authoritative safety information: Not specified for this item; consult the product SDS for GHS classification, hazard statements, pictograms, and detailed guidance.

General laboratory safety guidance for carbocyanine dyes (literature/good practice; not item-specific):

  • Likely hazards: may cause irritation to skin, eyes, and respiratory tract; harmful if swallowed; avoid inhalation of dusts and contact with skin/eyes.
  • Light sensitivity: protect from light to prevent photodegradation and potential formation of reactive byproducts.
  • PPE: wear appropriate lab coat, nitrile gloves, and chemical splash goggles; handle powders in a fume hood or ventilated enclosure to minimize dust inhalation.
  • Incompatibilities: avoid strong oxidizers and strong acids/bases that may degrade the chromophore; avoid azides/heavy metal salts in stock solutions that could catalyze degradation (general).
  • Spills: gently sweep/collect solid spills while minimizing dust; for solutions, absorb with inert material (e.g., vermiculite) and dispose according to institutional and local regulations.
  • First aid (overview):
    • Eye contact: rinse cautiously with water for several minutes; seek medical attention if irritation persists.
    • Skin contact: wash with soap and water; remove contaminated clothing.
    • Inhalation: move to fresh air; seek medical attention if symptoms occur.
    • Ingestion: rinse mouth; do not induce vomiting; seek medical attention.
  • Waste: dispose of dye-containing solutions as hazardous organic waste; do not discharge to drain.

Always defer to the SDS and institutional EHS policies for definitive handling procedures.

Solvent Selection

JC-1 is a cationic, lipophilic dye whose usability depends strongly on solvent choice (general/literature guidance).

  • Primary stock solvent: DMSO. Provides high solubility and stability for concentrated stocks (e.g., 1–5 mg/mL). Minimizes premature aggregation upon subsequent aqueous dilution.
  • Alternative solvents: DMF (good solubility), ethanol (moderate solubility; higher risk of precipitation upon aqueous dilution). Water alone is not recommended for preparing concentrated stocks due to limited solubility and aggregation.
  • Aqueous buffers: After dilution from DMSO/DMF stock, JC-1 can be used in physiological buffers (e.g., HBSS, PBS, culture media) at low micromolar working concentrations; maintain consistent final DMSO content (≤0.1–0.2% v/v) to minimize cell stress (literature/general).
  • Additives: Serum proteins and albumin can bind dyes and influence background and aggregation; optimize protein content empirically.
  • Light and temperature: Protect solutions from light and keep at room temperature or 37°C only during short incubations; store stocks cold and in the dark when not in use.

Quick comparison (general):

  • DMSO: highest solvating power; best for stable, concentrated stocks.
  • Ethanol: acceptable but increases risk of precipitation upon buffer dilution.
  • Water/buffer: only for final working dilutions prepared immediately before use; avoid concentrated aqueous storage.
Storage & Reconstitution

Item-specific storage and shipping:

  • Storage Conditions: Store at -20°C (as provided in Product Data). Protect from light.
  • Shipped In: Ice chest + Ice pads (as provided in Product Data).

Item-specific reconstitution details: Not specified for this item; refer to CoA/Spec Sheet.

General/literature guidance for handling JC-1 (not item-specific specifications):

  • Reconstitution: Prepare concentrated stock solutions in dry, oxygen-free DMSO (e.g., 1–5 mg/mL). Mix gently to avoid foaming and allow complete dissolution before use.
  • Aliquoting: Divide stock into single-use, amber or foil-wrapped microtubes to minimize freeze–thaw and light exposure.
  • Storage of stocks: Store aliquots at −20°C or below, protected from light and moisture. Avoid repeated freeze–thaw cycles.
  • Working solutions: Prepare immediately before use by diluting the DMSO stock into pre-warmed buffer/media; keep protected from light and use promptly to minimize aggregation and photobleaching.
  • Stability: Fluorophores can degrade upon exposure to light, oxygen, and moisture; monitor by UV–Vis/fluorescence for changes in absorbance/emission profiles if long-term storage is required.

Research Use Note: For research use only.

Structure & Identity

Brief overview: JC-1 is a cationic, lipophilic carbocyanine dye commonly used to monitor mitochondrial membrane potential (ΔΨm) via potential-dependent J-aggregate formation (general/literature).

Item-specific identifiers (from Product Data):

  • SKU: J755442
  • Product Name: JC-1
  • CAS: 47729-63-5
  • CID: 5492929
  • InChIKey: 95535 (as listed in catalog entry)
  • SMILES: Not specified for this item; refer to CoA/Spec Sheet.

Literature structural identity (general reference, not item-specific specifications):

  • Common chemical name: 5,5′,6,6′-Tetrachloro-1,1′,3,3′-tetraethylbenzimidazolylcarbocyanine iodide (JC-1)
  • Core scaffold: symmetric benzimidazolyl carbocyanine (tri-methine) dye with tetraethyl substitutions; tetrachloro substitution enhances hydrophobicity; paired with iodide counterion (general/literature).
  • Charge: cationic chromophore (+1) balanced by I⁻ (general/literature).
  • 2D structure description: two benzimidazolium rings connected by a conjugated trimethine bridge; each benzimidazole bears N-ethyl substituents; multiple chloro substituents at 5,5′,6,6′ positions (general/literature).
  • Molecular formula: Typically reported as C27H30Cl4N4·I (salt) (literature; exact empirical representation may vary by reporting convention).
  • Molecular weight: Typically ~652 g/mol for the iodide salt (literature).

Notes:

  • JC-1 exhibits potential-dependent supramolecular organization: monomers (green fluorescence) vs J-aggregates (red fluorescence) (general/literature).
  • For authoritative structural identifiers specific to this lot/item (e.g., exact SMILES/InChIKey), consult the CoA/Spec Sheet.
Synthetic Utility

JC-1 is a finished fluorescent probe and is not commonly used as a building block or reagent in organic synthesis. As such, typical synthetic utility considerations (e.g., functional group interconversions, cross-couplings) are not applicable.

General chemistry perspective (literature):

  • Structure: symmetric carbocyanine iodide composed of two benzimidazolium units linked by a trimethine bridge, with extensive conjugation and multiple chloro and ethyl substituents.
  • Reactivity: The dye is designed for photophysical stability and membrane partitioning rather than chemical reactivity. The cationic chromophore can be sensitive to strong nucleophiles and bases that disrupt the polymethine chain, and to strong oxidants that bleach the chromophore.
  • Handling: Avoid conditions that promote nucleophilic attack (strong base, thiolates) or oxidative bleaching (peroxides, singlet oxygen). Protect from light to preserve fluorescence.

If chemical modification of cyanine dyes is desired, synthetic access typically involves tailored indolinium/benzimidazolium precursors and polymethine couplings; however, JC-1 as supplied is not intended for derivatization in routine lab workflows.

Target Specificity

This product is not an antibody or affinity reagent; it does not have a defined antigen/epitope or species reactivity. JC-1 localizes to mitochondria based on membrane potential rather than binding a specific biomolecular target (general/literature).

Item-specific target/validation details: Not specified for this item; refer to the product datasheet.

Frequently Asked Questions

How should this product be stored?
Store at ?20 °C. Freezer storage is required to maintain the specified shelf life.
How is this product shipped?
This product ships in an insulated container with ice pads. Unpack on arrival and transfer it to the storage condition stated above.
What are the CAS number, molecular formula and molecular weight?
The CAS Number is 47729-63-5, the molecular formula is C25H27Cl4N4?I, and the molecular weight is 652.2 g/mol. InChIKey FYNNIUVBDKICAX-UHFFFAOYSA-M.
What documentation is provided?
Available product documentation, including Certificates of Analysis (COA), Safety Data Sheets (SDS), and specification sheets, is shown in the product document area. Document availability and access follow the current site policy.

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.