Reserpine - Moligand™, 10mM in DMSO , Synaptic vesicular amine transporter inhibitor, CAS No.50-55-5, Synaptic vesicular amine transporter inhibitor

CAS: 50-55-5 Cat. No.: R408290 Molecular Weight: 608.68 Beilstein Registry Number: 102014 EC Number: 200-047-9 PubChem CID: 5770
AVAILABLE TO ORDER
GRADE & PURITY Moligand™ ? Moligand™ — Aladdin's line of ligands and bioactive small molecules. Use for receptor, pathway, and binding studies needing defined small-molecule tools. 10mM in DMSO
Synonyms
11,17-Dimethoxy-18-[(3,4,5-trimethoxybenzoyl)oxy]yohimban-16-carboxylic acid methyl ester
Storage
Store at -80°C
Shipped In
Dry ice packs + Cold packs
Size
Status
Price
Qty
1ml
R408290-1ml
1

$132.90

$154.90
Save $22.00 (14.20%)
Enter a quantity for the sizes you want to add.
🧪

Why this grade

Moligand™, 10mM in DMSO Moligand™ for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Store at -80°C Ships Dry ice packs + Cold packs Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 30 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

Overview

Information

Reserpine Reserpine is an inhibitor of multidrug efflux pumps, used as an antipsychotic and antihypertensive drug. Reserpine is an inhibitor of the vesicular monoamine transporter 2 (VMAT2).
In vitro

Reserpine inhibits efflux pumps and reduces sparfloxacin, moxifloxacin and ciprofloxacin IC50s and MICs by up to four-fold in 11, 21 and 48 of the 102 unrelated clinical isolates tested.

In vivo

Reserpine (5 mg/kg s.c.) reduces extracellular DA levels to 4% of basal values in intact rats. Reserpine (5 mg/kg s.c.) diminishes L-DOPA (50 mg/kg i.p.)-induced increases in extracellular dopamine levels to 16% of those obtained in denervated animals not pretreated with reserpine in 6-hydroxydopamine-lesioned rats. Reserpine causes a marked depletion of Vasotocin/oxytocin-neu-rophysin-like immunoreactivity (LI) and CRH-L1 in the median eminence of the rat. Reserpine significantly restores performance on the delayed response task in monkeys. Reserpine has little effect on performance of a visual discrimination task, a reference memory task which does not depend on the prefrontal cortex. Reserpine injection (one dose of 1 mg/kg s.c.) every other day for 3 days causes a significant increase in vacuous chewing, tongue protrusion and duration of facial twitching in rats, compared to the control. Reserpine results in a decreased glutamate uptake in the subcortical parts of rats. Reserpine (5 mg/kg) significantly increases vacuous jaw movements, and also reduces rearing behavior in all age groups of rats.
Cell Data

cell lines:Prostate(LNCap,PC3), Cervix(HeLa), Pancreas(ASPC1), Sarcoma(Saos-2)Ovary(OVCAR8), Stomach(NCI-N87), Melanoma(SKMEL3,A431, MALME3M), Colon(Colo205,SW620,HCT116), Breast(SKBR3,MDA-MB-453,MCF7), Lung(NCI-H82,MV522,NCI-H522), etc.

Concentrations:

Incubation Time:

Powder Purity:≥99%

Specifications

Synonyms
11, 17-Dimethoxy-18-[(3, 4, 5-trimethoxybenzoyl)oxy]yohimban-16-carboxylic acid methyl ester
Specifications & Purity
Moligand™, 10mM in DMSO
Biochemical and Physiological Mechanisms
Reserpine is an inhibitor of multidrug efflux pumps, used as an antipsychotic and antihypertensive drug. Reserpine is an inhibitor of the vesicular monoamine transporter 2 (VMAT2).
Storage
Store at -80°C
Shipped In
Dry ice packs + Cold packs
This product requires cold chain shipping. Ground and other economy services are not available.
Grade
Moligand™
Action Type
INHIBITOR
Mechanism of action
Synaptic vesicular amine transporter inhibitor
Product Properties
ALogP4
Names and Identifiers
Isomeric SMILES CO[C@H]1[C@@H](C[C@@H]2CN3CCC4=C([C@H]3C[C@@H]2[C@@H]1C(=O)OC)NC5=C4C=CC(=C5)OC)OC(=O)C6=CC(=C(C(=C6)OC)OC)OC
WGK Germany 3
PubChem CID 5770
UN Number 3077
Packing Group III
Molecular Weight 608.68
Beilstein 102014

Documentation

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Associated Targets(Human)
ABCB1 Tchem Multidrug resistance protein 1 (0 Activities)
Activity TypeActivity Value -log(M)Mechanism of ActionActivity ReferencePublications (PubMed IDs)
SLC18A1 Tchem Chromaffin granule amine transporter (1 Activities)
Activity TypeActivity Value -log(M)Mechanism of ActionActivity ReferencePublications (PubMed IDs)
SLC18A2 Tclin Synaptic vesicular amine transporter (1 Activities)
Activity TypeActivity Value -log(M)Mechanism of ActionActivity ReferencePublications (PubMed IDs)
Certificates(CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:
Chemical and Physical Properties
Specific Rotation[α]177° (C=1,DMF)
Flash Point(°F)22 °C
Flash Point(°C)22°C
Documents & Articles
Citations of This Product
References
1. Shuxiong Yan, Ke Ma, Yi Ren, Yi Hong, Zhengge Chen, Qi Huang, Hui Zhu, Zhengxu Huang.  (2023)  Design and performance of a dual stage asymmetric ion funnel interface.  INTERNATIONAL JOURNAL OF MASS SPECTROMETRY,      [PMID:] [10.1016/j.ijms.2023.117133]
2. Weimin Wang, Chaohui Qiu, Fuxing Xu, Li Ding, Chuan-Fan Ding.  (2023)  Genetic Algorithm Optimized Printed Circuit Board Ion Funnel Tandem Subambient Pressure Ionization with Nanoelectrospray (SPIN) for High Sensitivity Mass Spectrometry.  JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY,      [PMID:37463266] [10.1021/jasms.3c00205]
3. Fuxing Xu, Weimin Wang, Li Ding, Xiang Fang, Chuan-Fan Ding.  (2022)  Synchronized Reverse Scan Collision Induced Dissociation in Digital Ion Trap Mass Spectrometer for Improving Fragment Ion Detection.  ANALYTICAL CHEMISTRY,      [PMID:36512629] [10.1021/acs.analchem.2c03524]
4. Song Cheng, Zhang Yunpeng, Manzoor Muhammad Aamir, Li Guohui.  (2022)  Identification of alkaloids and related intermediates of Dendrobium officinale by solid-phase extraction coupled with high-performance liquid chromatography tandem mass spectrometry.  Frontiers in Plant Science,      [PMID:35991437] [10.3389/fpls.2022.952051]
5. Jun Li, Huanming Wu, Jiancheng Yu, Junliang Zhang, Chenlu Wang, Fuxing Xu, Weimin Wang, Zhibin Xie, Tao Yin, Keqi Tang.  (2022)  Enhanced Sensitivity and Precision of Portable Mass Spectrometry (MS) with a Discontinuous Atmospheric Pressure Interface by Multiple Ion Injection.  ANALYTICAL LETTERS,      [PMID:] [10.1080/00032719.2021.1922430]
6. Fuxing Xu, Weimin Wang, Xinhua Dai, Xiang Fang, Chuan-Fan Ding.  (2021)  Investigation of the effect of an octopole electric field on a linear ion trap and an asymmetric semi-circular linear ion trap analyzer.  ANALYST,  146  (21): (6455-6462).  [PMID:34596639] [10.1039/D1AN01604K]
7. Hao Gu, Kang Ma, Weiqian Zhao, Lirong Qiu, Wei Xu.  (2021)  A general purpose MALDI matrix for the analyses of small organic, peptide and protein molecules.  ANALYST,  146  (12): (4080-4086).  [PMID:34052846] [10.1039/D1AN00474C]
8. Fuxing Xu, Weimin Wang, Liuyu Jin, Bingjun Qian, Chuan-Fan Ding.  (2021)  Measurement of the effective electric field radius on digital ion trap spectrometer.  ANALYST,  146  (12): (3810-3817).  [PMID:33977965] [10.1039/D1AN00468A]
9. Liu Mingyang, Du Xuejun, Xu Ke, Yan Binwei, Fan Zaibi, Gao Zideng, Ren Xueqin.  (2021)  A cationic quantum dot-based ratiometric fluorescent probe to visually detect berberine hydrochloride in human blood serums.  Journal of Analytical Science and Technology,  12  (1): (1-9).  [PMID:] [10.1186/s40543-021-00261-x]
10. Lan Zhang, Yue Yang, Lei Di, Jun-long Li, Ning Li.  (2020)  Erxian decoction, a famous Chinese medicine formula, antagonizes corticosterone-induced injury in PC12 cells, and improves depression-like behaviours in mice.  PHARMACEUTICAL BIOLOGY,      [PMID:32476554] [10.1080/13880209.2020.1765812]
11. Song Cheng, Jiao Chunyan, Jin Qing, Chen Cunwu, Cai Yongping, Lin Yi.  (2020)  Metabolomics analysis of nitrogen-containing metabolites between two Dendrobium plants.  PHYSIOLOGY AND MOLECULAR BIOLOGY OF PLANTS,  26  (7): (1425-1435).  [PMID:32647459] [10.1007/s12298-020-00822-1]
12. Wang Guoli, Lei Cong, Tian Ya, Wang Yingping, Zhang Lianxue, Zhang Ronghua.  (2019)  Rb1, the Primary Active Ingredient in Panax ginseng C.A. Meyer, Exerts Antidepressant-Like Effects via the BDNF–Trkb–CREB Pathway.  Frontiers in Pharmacology,      [PMID:31572200] [10.3389/fphar.2019.01034]
13. Xinwei Liu, Xiao Wang, Jiexun Bu, Xiaoyu Zhou, Zheng Ouyang.  (2018)  Tandem Analysis by a Dual-Trap Miniature Mass Spectrometer.  ANALYTICAL CHEMISTRY,      [PMID:30444599] [10.1021/acs.analchem.8b03958]
14. Ning Chen, Weixia Li, Shuchao Wu, Yan Zhu.  (2018)  Fluorimetric detection of reserpine in mouse serum through online post-column electrochemical derivatization.  Royal Society Open Science,  (8):   [PMID:30224984] [10.1098/rsos.171948]
15. Xiaoyu Zhou, Xinwei Liu, Spencer Chiang, Wenbo Cao, Ming Li, Zheng Ouyang.  (2018)  Stimulated Motion Suppression (STMS): a New Approach to Break the Resolution Barrier for Ion Trap Mass Spectrometry.  JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY,      [PMID:29845562] [10.1007/s13361-018-1995-x]
16. Pan Fang, Jian-Zhang Pan, Qun Fang.  (2017)  A robust and extendable sheath flow interface with minimal dead volume for coupling CE with ESI-MS.  TALANTA,      [PMID:29332826] [10.1016/j.talanta.2017.12.046]
17. Cong-Min Huang, Ying Zhu, Di-Qiong Jin, Ryan T. Kelly, Qun Fang.  (2017)  Direct Surface and Droplet Microsampling for Electrospray Ionization Mass Spectrometry Analysis with an Integrated Dual-Probe Microfluidic Chip.  ANALYTICAL CHEMISTRY,      [PMID:28780855] [10.1021/acs.analchem.7b01679]
18. Fuxing Xu, Qiankun Dang, Xinhua Dai, Xiang Fang, Yuanyuan Wang, Li Ding, Chuan-Fan Ding.  (2016)  Characteristics of Ion Activation and Collision Induced Dissociation Using Digital Ion Trap Technology.  JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY,      [PMID:27150507] [10.1007/s13361-016-1407-z]
19. Yang Li, Zhenqing Wei, Bin Dong, Zhigang Lian, Yinghui Xu.  (2016)  Silencing of phosphoglucose isomerase/autocrine motility factor decreases U87 human glioblastoma cell migration.  INTERNATIONAL JOURNAL OF MOLECULAR MEDICINE,  37  (4): (998-1004).  [PMID:26936801] [10.3892/ijmm.2016.2500]
20. Yinjuan Chen, Chongsheng Xu, Fuxing Xu, Kai Yang, Qiang Wang, Xin Zhao, Yuanyuan Wang, Bin Chen, Chuan-Fan Ding.  (2016)  Electro-Filtering Spray Ionization Source for Soil Analysis.  ANALYTICAL LETTERS,      [PMID:] [10.1080/00032719.2015.1070163]
21. Qing Wang, Yao Long, Lin Yao, Li Xu, Zhi-Guo Shi, Lanying Xu.  (2015)  Preparation, characterization and application of a reversed phase liquid chromatography/hydrophilic interaction chromatography mixed-mode C18-DTT stationary phase.  TALANTA,      [PMID:26695288] [10.1016/j.talanta.2015.09.009]
22. Fu-Xing XU, Qian-Kun DANG, Yin-Juan CHEN, Kai YANG, Qiang WANG, Bin CHEN, Yuan-Yuan WANG, Chuan-Fan DING.  (2015)  Rapid Mass Analysis of Reserpine and Arginine by Ion Trap Mass Spectrometer.  CHINESE JOURNAL OF ANALYTICAL CHEMISTRY,      [PMID:] [10.1016/S1872-2040(15)60833-7]
23. Zhong-yao Zhang, Cuiping Li, Chuan-fan Ding, Fuxing Xu, Baoqiang Li, Qibin Huang, Hengxin Xia.  (2014)  A novel asymmetrical arc-shaped electrode ion trap for improving the performance of a miniature mass spectrometer.  RAPID COMMUNICATIONS IN MASS SPECTROMETRY,  28  (15): (1764-1768).  [PMID:24975257] [10.1002/rcm.6951]
24. Liang Wang, Fuxing Xu, Xinhua Dai, Xiang Fang, Chuan-Fan Ding.  (2014)  Development and Investigation of a Mesh-Electrode Linear Ion Trap (ME-LIT) Mass Analyzer.  JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY,      [PMID:24435796] [10.1007/s13361-013-0803-x]
25. Dan Jiang, Gong-Yu Jiang, Xiao-Xu Li, Fu-xing Xu, Liang Wang, Li Ding, Chuan-Fan Ding.  (2013)  Printed Circuit Board Ion Trap Mass Analyzer: Its Structure and Performance.  ANALYTICAL CHEMISTRY,      [PMID:23701673] [10.1021/ac400864k]
26. Changjuan Guo, Zhongyao Jiang, Chunguang Xie, Hui Zhu, Wei Gao, Zhengxu Huang, Ping Cheng, Zhong Fu, Zhen Zhou.  (2012)  A radio frequency signal driver for quadrupole used in desktop orthogonal-injection time-of-flight mass spectrometer.  NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,      [PMID:] [10.1016/j.nima.2012.07.048]
27. Likai Xing, Daoxue Liu, Haohan Yu, Haibo Ding, Jie Sun, Guozhen Wang, Yuanyuan Deng, Wenya Chang, Zhuoying Xie.  (2025)  Two-Photon Direct Laser Writing of Capillary-Coupled Nanosprayer Arrays for ESI-MS.  ANALYTICAL CHEMISTRY,      [PMID:39907515] [10.1021/acs.analchem.4c06537]
28. Yanqing Ma, Shuanghe Wang, Shanshan Luo, Yixi Zeng, Guofeng Shi, Lanyue zhang, Hui Li.  (2025)  Antidepressant-like Effects of Five Essential Oils Inhaled in Reserpine-induced Depressed Mouse Models.  CHEMISTRY & BIODIVERSITY,      [PMID:40644689] [10.1002/cbdv.202500971]
29. Mengfei Shan, La Chen, Jun Wang, Luhong Wen.  (2025)  Dual-Channel Off-Axis Ion Funnel With a Deflection Electrode.  RAPID COMMUNICATIONS IN MASS SPECTROMETRY,  39  (20): (e10103).  [PMID:40589310] [10.1002/rcm.10103]
30. Hao Hu, Shao-Ju Luo, Zhi-rui Cao, Yingzi Wu, Zhuomao Mo, Yongdan Wang, Ling Yu, Yan Chen, Liang Xu, Shi-Jun Zhang.  (2020)  Depressive Disorder promotes Hepatocellular Carcinoma metastasis via upregulation of ABCG2 gene expression and maintenance of self-renewal.  Journal of Cancer,      [PMID:32742477] [10.7150/jca.45712]
Solution Calculators
Reviews

Customer Reviews

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.