EDTA Antigen Retrieval Solution (50X) - BioReagent, sterile-filtered, Suitable for Immunohistochemistry, sterile, 50X

Cat. No.: E745530
AVAILABLE TO ORDER
GRADE & PURITY Sterile-filtered ? Sterile-filtered — passed through a 0.2µm filter to remove microorganisms. Use as a ready aseptic solution for culture and sensitive applications. BioReagent ? BioReagent grade — tested suitable for life-science and molecular-biology use. Use for cell culture, assays, and biochemical work needing biological compatibility. Sterile ? Sterile grade — processed and verified free of viable microorganisms. Use directly in aseptic procedures and cell culture without further sterilization. Suitable for Immunohistochemistry(IHC) ? IHC grade — validated for immunohistochemistry on tissue sections. Use to detect and localize antigens in fixed tissue. 50X
Storage
Store at 2-8°C
Shipped In
Wet ice
 ·  off list, applied to all prices below.
Size
Status
Price
Qty
100ml
E745530-100ml
2
$36.90
500ml
E745530-500ml
1
$87.90
Enter a quantity for the sizes you want to add.
🧪

Why this grade

BioReagent, sterile-filtered, Suitable for Immunohistochemistry, sterile, 50X BioReagent,Sterile,Sterile-filtered,Suitable for Immunohistochemistry(IHC) for sensitive chromatographic and analytical workflows requiring minimal baseline interference.

🌡

Storage & shipping

Store at 2-8°C Ships Wet ice Check lot-specific COA for exact specifications.

📋

Quality documents

SDS, COA, datasheet, and spec sheet available for download. Lot-specific COA accessible via lot number lookup.

📚

Literature proof

Cited in 0 peer-reviewed publications across chromatography, organic synthesis, and cross-coupling reactions.

Overview

Product Introduction:
The EDTA antigen repair solution (50x) uses widely used EDTA, which has the ability to repair protein crosslinks caused by fixatives such as paraformaldehyde. Whether it is paraffin sections, frozen sections, or cell slides, as long as the sample is fixed with paraformaldehyde, formaldehyde, or other aldehyde reagents, antigen repair will effectively remove protein crosslinks, fully expose antigen epitopes, and greatly improve immunostaining efficiency.
Operation process:
1. Before preparing the reagent for use, it is necessary to dilute EDTA antigen retrieval solution (50 x) with distilled water or ultrapure water to prepare an antigen retrieval solution (1 x).
2. Antigen repair
2.1 For paraffin sections:
2.1.1 Dewaxing: The slices are dewaxed in xylene for 2 × 5 minutes. Anhydrous ethanol for 2 × 5 minutes. 90% ethanol for 2 × 5 minutes, 70% ethanol for 5 minutes. Distilled water for 2 × 5 minutes.
2.1.2 Antigen retrieval: Soak the slices in antigen retrieval solution (1 ×) and heat them at 95-100 ° C for about 10-30 minutes (the optimal heating time needs to be explored according to different samples and target proteins).
Note: The antigen repair solution (1 ×) needs to be preheated to 95-100 ° C before use. Heating can be done using a water bath or microwave. If using a microwave oven for heating, be careful to avoid boiling the repair solution. Then cool to room temperature for approximately 20-30 minutes. Wash 1-2 times with immunostaining detergent, each time for 3-5 minutes. Subsequent immunostaining steps such as sealing can be performed.
2.2 Frozen sections: Wash the sections with immunostaining detergent for 5 minutes. The process of antigen repair is similar to the antigen repair process of paraffin sections.
2.3 For antigen repair of other samples, the steps for paraffin sectioning can be followed.
Reminder: For your own safety, please take protective measures such as wearing lab coats and gloves before using the reagents.




Specifications

Specifications & Purity
BioReagent, sterile-filtered, Suitable for Immunohistochemistry, sterile, 50X
Stability And Storage
Store at 2-8℃ for 12 months. Store at -20℃ for 24 months. Upon receipt, it is recommended to aliquot. Avoid freeze/thaw cycle.
Storage
Store at 2-8°C
Shipped In
Wet ice
This product requires cold chain shipping. Ground and other economy services are not available.
Grade
BioReagent, Sterile, Sterile-filtered, Suitable for Immunohistochemistry(IHC)

Documentation

📋 Safety Data Sheet (SDS)

Comprehensive hazard, handling, storage, and regulatory compliance document.

Download SDS →

✅ Certificate of Analysis (COA)

Lot-specific quality data. Enter your lot number to retrieve the exact COA.

Look up COA →

📊 Datasheet

Quick-reference summary of product specifications and applications.

View datasheet →

🔬 Specification Sheet

Full quality attributes and acceptance criteria for this grade.

View spec sheet →

Advanced Data

Certificates(CoA,COO,BSE/TSE and Analysis Chart)
C of A & Other Certificates(BSE/TSE, COO):
Analytical Chart:

Find and download the COA for your product by matching the lot number on the packaging.

4 results found

Lot NumberCertificate TypeDateItem
ZJ25F0724967Certificate of AnalysisMay 22, 2026 E745530
ZJ25F0724999Certificate of AnalysisMay 22, 2026 E745530
ZJ25F0420221Certificate of AnalysisFeb 24, 2026 E745530
ZJ25F0420222Certificate of AnalysisFeb 24, 2026 E745530
Documents & Articles
Solution Calculators
Reviews

Customer Reviews

Shall we send you a message when we have discounts available?

Remind me later

Thank you! Please check your email inbox to confirm.

Oops! Notifications are disabled.