GRADE & PURITYValidated?Validated grade — performance confirmed in defined applications before release. Use when you want documented assurance the reagent works as stated.ExactAb™?ExactAb™ — Aladdin's antibody line emphasizing precision and validated quality. Use for reliable, specificity-validated antibody applications.Ex:565nm?Fluorescence excitation maximum at 565 nm — the wavelength of light that best excites this fluorophore. Match it to your instrument's laser or filter set for the strongest signal.Em:575nm?Fluorescence emission maximum at 575 nm — the wavelength this fluorophore emits after excitation. Use it to pick the right detection filter and avoid channel cross-talk.See COA
Mouse anti Human HLA Class I Antibody, Monoclonal (W6/32), could be used for WB, Flow, IP, IHC, ICC/IF, Functional Assays and so on.
Specifications
Product Name
HLA Class I Mouse mAb (PE) - Primary antibody
Synonyms
A-10 alpha chain | FLJ26655 | HLA class I histocompatibility antigen, A-1 alpha chain | HLA class I histocompatibility antigen, A-28 alpha chain | HLA class I histocompatibility antigen, A-9 alpha chain | HLA Class I | HLAA | HLA-A | HLA-ABC | major histo
Specifications & Purity
ExactAb™, Validated, Ex:565nm, Em:575nm, See COA
Host species
Mouse
Immunogen
Human tonsil cell membrane
Conjugation
PE
Excitation (nm)
Blue Laser(488nm), Green Laser(532nm), Yellow-Green Laser(561nm)
Emission(nm)
575nm
Ex/Em(nm)
Ex:565nm;Em:575nm
Grade
Em:575nm, Ex:565nm, ExactAb™, Validated
Light Chain Type
kappa
Purification Method
Protein G purified
Concentration
See COA
Storage and Shipping
Storage
Store at 2-8°C,Protected from light,Do not freeze
Shipped In
Wet ice,Do not freeze
Stability And Storage
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Images
HLA Class I Mouse mAb (PE) (Ab191636) - Flow Cytometry Flow cytometry analysis of HLA Class I expression by human peripheral blood lymphocytes (right panel) compared to an isotype control (left panel). Cells were stained with HLA Class I Mouse mAb (PE) (Ab191636) at 1μL/test for 1 hour at 4°C. Left panel - Mouse IgG (PE) (Ab180308).
HLA Class I Mouse mAb (PE) (Ab191636) - Flow Cytometry Flow cytometry analysis of HLA Class I expression by human peripheral blood lymphocytes (red) compared to an isotype control (blue). Cells were stained with HLA Class I Mouse mAb (PE) (Ab191636) at 1μL/test for 1 hour at 4°C. Blue - Mouse IgG (PE) (Ab180308). Black - Unlabelled control, cells without incubation with primary antibody.
Application
Application
Dilution info
Flow Cytometry
≤ 1.0 µg per million cells in 100 µl volume or 100 µl of whole blood
Documentation
📋 Safety Data Sheet (SDS)
Comprehensive hazard, handling, storage, and regulatory compliance document.
Determine the necessary mass, volume, or concentration for preparing a solution.
Dilution Calculator
Determine the dilution needed to prepare a stock solution.
Reconstitution Calculator
Reviews
Customer Reviews
We use cookies to ensure the website functions properly and, where permitted, to improve your experience. You can manage your preferences at any time in Settings. Learn more in our Cookie Policy.
Shall we send you a message when we have discounts available?
Remind me later
Thank you! Please check your email inbox to confirm.
Products are supplied to verified businesses, institutions, and qualified professionals for research and development use only. Not for use in humans, animals, diagnosis, or therapy.